{"title":"成人 Iohexol 血浆清除率测量协议标准化--欧洲肾功能联合会共识文件。","authors":"","doi":"10.1016/j.kint.2024.06.029","DOIUrl":null,"url":null,"abstract":"<div><p>International consensus supports the development of standardized protocols for measured glomerular filtration rate (mGFR) to facilitate the integration of mGFR testing in both clinical and research settings. To this end, the European Kidney Function Consortium convened an international group of experts with relevant experience in mGFR. The working group performed an extensive literature search to inform the development of recommendations for mGFR determination using 1-compartment plasma clearance models and iohexol as the exogenous filtration marker. Iohexol was selected as it is non–radio labeled, inexpensive, and safe, can be assayed at a central laboratory, and the other commonly used non–radio-labeled tracers have been (inulin) or are soon to be (iothalamate) discontinued. A plasma clearance model was selected over urine clearance as it requires no urine collection. A 1 compartment was preferred to 2 compartments as it requires fewer samples. The recommendations are based on published evidence complemented by expert opinion. The consensus paper covers practical advice for patients and health professionals, preparation, administration, and safety aspects of iohexol, laboratory analysis, blood sample collection and sampling times using both multiple and single-sample protocols, description of the mGFR mathematical calculations, as well as implementation strategies. Supplementary materials include patient and provider information sheets, standard operating procedures, a study protocol template, and support for mGFR calculation.</p></div>","PeriodicalId":17801,"journal":{"name":"Kidney international","volume":null,"pages":null},"PeriodicalIF":14.8000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0085253824005374/pdfft?md5=a5d0dff4d8d7e650e3423803368e25c3&pid=1-s2.0-S0085253824005374-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Iohexol plasma clearance measurement protocol standardization for adults: a consensus paper of the European Kidney Function Consortium\",\"authors\":\"\",\"doi\":\"10.1016/j.kint.2024.06.029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>International consensus supports the development of standardized protocols for measured glomerular filtration rate (mGFR) to facilitate the integration of mGFR testing in both clinical and research settings. To this end, the European Kidney Function Consortium convened an international group of experts with relevant experience in mGFR. The working group performed an extensive literature search to inform the development of recommendations for mGFR determination using 1-compartment plasma clearance models and iohexol as the exogenous filtration marker. Iohexol was selected as it is non–radio labeled, inexpensive, and safe, can be assayed at a central laboratory, and the other commonly used non–radio-labeled tracers have been (inulin) or are soon to be (iothalamate) discontinued. A plasma clearance model was selected over urine clearance as it requires no urine collection. A 1 compartment was preferred to 2 compartments as it requires fewer samples. The recommendations are based on published evidence complemented by expert opinion. The consensus paper covers practical advice for patients and health professionals, preparation, administration, and safety aspects of iohexol, laboratory analysis, blood sample collection and sampling times using both multiple and single-sample protocols, description of the mGFR mathematical calculations, as well as implementation strategies. Supplementary materials include patient and provider information sheets, standard operating procedures, a study protocol template, and support for mGFR calculation.</p></div>\",\"PeriodicalId\":17801,\"journal\":{\"name\":\"Kidney international\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":14.8000,\"publicationDate\":\"2024-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0085253824005374/pdfft?md5=a5d0dff4d8d7e650e3423803368e25c3&pid=1-s2.0-S0085253824005374-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kidney international\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0085253824005374\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kidney international","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0085253824005374","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

国际共识支持制定测定肾小球滤过率(mGFR)的标准化方案,以促进 mGFR 检测在临床和研究环境中的整合。为此,欧洲肾功能联合会召集了一批在 mGFR 方面具有相关经验的国际专家。工作组进行了广泛的文献检索,为使用单室血浆清除率模型和碘海醇作为外源性滤过标记物来测定 mGFR 提供了参考建议。之所以选择异己醇,是因为它无放射性标记、价格低廉、安全、可在中心实验室进行测定,而其他常用的无放射性标记示踪剂已经(菊粉)或即将(碘海氨酸)停用。选择血浆清除率模型而非尿液清除率模型,是因为它不需要收集尿液。单室比双室更受欢迎,因为它需要的样本更少。这些建议基于已发表的证据,并辅以专家意见。共识文件涵盖了对患者和医疗专业人员的实用建议,碘海醇的准备、管理和安全性,实验室分析,血液样本采集和使用多样本和单样本方案的采样时间,mGFR 数学计算的说明以及实施策略。补充材料包括患者和提供者信息表、标准操作程序、研究方案模板以及 mGFR 计算支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Iohexol plasma clearance measurement protocol standardization for adults: a consensus paper of the European Kidney Function Consortium

International consensus supports the development of standardized protocols for measured glomerular filtration rate (mGFR) to facilitate the integration of mGFR testing in both clinical and research settings. To this end, the European Kidney Function Consortium convened an international group of experts with relevant experience in mGFR. The working group performed an extensive literature search to inform the development of recommendations for mGFR determination using 1-compartment plasma clearance models and iohexol as the exogenous filtration marker. Iohexol was selected as it is non–radio labeled, inexpensive, and safe, can be assayed at a central laboratory, and the other commonly used non–radio-labeled tracers have been (inulin) or are soon to be (iothalamate) discontinued. A plasma clearance model was selected over urine clearance as it requires no urine collection. A 1 compartment was preferred to 2 compartments as it requires fewer samples. The recommendations are based on published evidence complemented by expert opinion. The consensus paper covers practical advice for patients and health professionals, preparation, administration, and safety aspects of iohexol, laboratory analysis, blood sample collection and sampling times using both multiple and single-sample protocols, description of the mGFR mathematical calculations, as well as implementation strategies. Supplementary materials include patient and provider information sheets, standard operating procedures, a study protocol template, and support for mGFR calculation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Kidney international
Kidney international 医学-泌尿学与肾脏学
CiteScore
23.30
自引率
3.10%
发文量
490
审稿时长
3-6 weeks
期刊介绍: Kidney International (KI), the official journal of the International Society of Nephrology, is led by Dr. Pierre Ronco (Paris, France) and stands as one of nephrology's most cited and esteemed publications worldwide. KI provides exceptional benefits for both readers and authors, featuring highly cited original articles, focused reviews, cutting-edge imaging techniques, and lively discussions on controversial topics. The journal is dedicated to kidney research, serving researchers, clinical investigators, and practicing nephrologists.
期刊最新文献
Corrigendum to "Acute kidney injury genetic risks: taking it 1 SNP at a time." Kidney International 2024;106:188-190. Corrigendum to "Early treatment with xenon protects against the cold ischemia associated with chronic allograft nephropathy in rats." Kidney International 2013;85:112-123. Hyponatremia associated with acute intermittent porphyria. Kidney failure and a reticulated dermatosis. Looking into the cholesterol crystal ball: is complement the answer?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1