{"title":"成人 Iohexol 血浆清除率测量协议标准化--欧洲肾功能联合会共识文件。","authors":"","doi":"10.1016/j.kint.2024.06.029","DOIUrl":null,"url":null,"abstract":"<div><p>International consensus supports the development of standardized protocols for measured glomerular filtration rate (mGFR) to facilitate the integration of mGFR testing in both clinical and research settings. To this end, the European Kidney Function Consortium convened an international group of experts with relevant experience in mGFR. The working group performed an extensive literature search to inform the development of recommendations for mGFR determination using 1-compartment plasma clearance models and iohexol as the exogenous filtration marker. Iohexol was selected as it is non–radio labeled, inexpensive, and safe, can be assayed at a central laboratory, and the other commonly used non–radio-labeled tracers have been (inulin) or are soon to be (iothalamate) discontinued. A plasma clearance model was selected over urine clearance as it requires no urine collection. A 1 compartment was preferred to 2 compartments as it requires fewer samples. The recommendations are based on published evidence complemented by expert opinion. The consensus paper covers practical advice for patients and health professionals, preparation, administration, and safety aspects of iohexol, laboratory analysis, blood sample collection and sampling times using both multiple and single-sample protocols, description of the mGFR mathematical calculations, as well as implementation strategies. Supplementary materials include patient and provider information sheets, standard operating procedures, a study protocol template, and support for mGFR calculation.</p></div>","PeriodicalId":17801,"journal":{"name":"Kidney international","volume":null,"pages":null},"PeriodicalIF":14.8000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0085253824005374/pdfft?md5=a5d0dff4d8d7e650e3423803368e25c3&pid=1-s2.0-S0085253824005374-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Iohexol plasma clearance measurement protocol standardization for adults: a consensus paper of the European Kidney Function Consortium\",\"authors\":\"\",\"doi\":\"10.1016/j.kint.2024.06.029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>International consensus supports the development of standardized protocols for measured glomerular filtration rate (mGFR) to facilitate the integration of mGFR testing in both clinical and research settings. To this end, the European Kidney Function Consortium convened an international group of experts with relevant experience in mGFR. The working group performed an extensive literature search to inform the development of recommendations for mGFR determination using 1-compartment plasma clearance models and iohexol as the exogenous filtration marker. Iohexol was selected as it is non–radio labeled, inexpensive, and safe, can be assayed at a central laboratory, and the other commonly used non–radio-labeled tracers have been (inulin) or are soon to be (iothalamate) discontinued. A plasma clearance model was selected over urine clearance as it requires no urine collection. A 1 compartment was preferred to 2 compartments as it requires fewer samples. The recommendations are based on published evidence complemented by expert opinion. The consensus paper covers practical advice for patients and health professionals, preparation, administration, and safety aspects of iohexol, laboratory analysis, blood sample collection and sampling times using both multiple and single-sample protocols, description of the mGFR mathematical calculations, as well as implementation strategies. Supplementary materials include patient and provider information sheets, standard operating procedures, a study protocol template, and support for mGFR calculation.</p></div>\",\"PeriodicalId\":17801,\"journal\":{\"name\":\"Kidney international\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":14.8000,\"publicationDate\":\"2024-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0085253824005374/pdfft?md5=a5d0dff4d8d7e650e3423803368e25c3&pid=1-s2.0-S0085253824005374-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kidney international\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0085253824005374\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kidney international","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0085253824005374","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
Iohexol plasma clearance measurement protocol standardization for adults: a consensus paper of the European Kidney Function Consortium
International consensus supports the development of standardized protocols for measured glomerular filtration rate (mGFR) to facilitate the integration of mGFR testing in both clinical and research settings. To this end, the European Kidney Function Consortium convened an international group of experts with relevant experience in mGFR. The working group performed an extensive literature search to inform the development of recommendations for mGFR determination using 1-compartment plasma clearance models and iohexol as the exogenous filtration marker. Iohexol was selected as it is non–radio labeled, inexpensive, and safe, can be assayed at a central laboratory, and the other commonly used non–radio-labeled tracers have been (inulin) or are soon to be (iothalamate) discontinued. A plasma clearance model was selected over urine clearance as it requires no urine collection. A 1 compartment was preferred to 2 compartments as it requires fewer samples. The recommendations are based on published evidence complemented by expert opinion. The consensus paper covers practical advice for patients and health professionals, preparation, administration, and safety aspects of iohexol, laboratory analysis, blood sample collection and sampling times using both multiple and single-sample protocols, description of the mGFR mathematical calculations, as well as implementation strategies. Supplementary materials include patient and provider information sheets, standard operating procedures, a study protocol template, and support for mGFR calculation.
期刊介绍:
Kidney International (KI), the official journal of the International Society of Nephrology, is led by Dr. Pierre Ronco (Paris, France) and stands as one of nephrology's most cited and esteemed publications worldwide.
KI provides exceptional benefits for both readers and authors, featuring highly cited original articles, focused reviews, cutting-edge imaging techniques, and lively discussions on controversial topics.
The journal is dedicated to kidney research, serving researchers, clinical investigators, and practicing nephrologists.