Yalin Lu, Liang Ma, Jian Yang, Xinyang Jin, Tao Wang, Jing Gao, Yawen Li, Ni Zhang, Qingxiong Yue, Shijun Li
{"title":"持续性心房颤动患者的双心房基底与射频消融术后复发之间的关系。","authors":"Yalin Lu, Liang Ma, Jian Yang, Xinyang Jin, Tao Wang, Jing Gao, Yawen Li, Ni Zhang, Qingxiong Yue, Shijun Li","doi":"10.1111/pace.15054","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Global longitudinal strain (GLS) and atrial voltage are acknowledged markers for worse rhythm outcome after ablation of persistent atrial fibrillation (PeAF). The majority of research efforts have been directed towards the left atrium (LA), with relatively fewer studies focusing on the right atrium (RA). The aim of this study was to investigate the effect of the biatrial substrate on the outcome following radiofrequency catheter ablation (RFCA).</p><p><strong>Methods: </strong>All patients underwent two-dimensional speckle tracking echocardiography (2D-STE) and high-density mapping (HDM) on LA and RA in preoperative and postoperative stages of RFCA. Atrial substrate was assessed by GLS, average voltage, and low voltage zone (LVZ).</p><p><strong>Results: </strong>This retrospective study enrolled 48 patients. With a follow-up of 385.98 ± 161.78 days, 22.92% (11/48) of all patients had AF recurrence and 63.64% in low strain group. Left atrial-low voltage zone (LA-LVZ) prior to RFCA was 67.52 ± 15.27% and 54.21 ± 20.07%, respectively, in the recurrence group and non-recurrence group. Multivariate regression analysis showed that preoperative LA-GLS (OR 0.047, 95%CI 0.002-0.941, p = .046) was independent predictors of AF recurrence. Biatrial average voltage in preoperative and postoperative stages were positively correlated (preoperative: r = 0.563 p < .001; postoperative: r = 0.464 p = .002). There was no significant difference in the proportion of RA in the recurrence group except the septum in preoperative and postoperative stages.</p><p><strong>Conclusions: </strong>Low LA-GLS and high LA-LVZ may be predictors of RFCA recurrence in PeAF patients. Biatrial average voltage were positively correlated in preoperative and postoperative stages.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Relationships between biatrial substrate and recurrence after radiofrequency ablation in patients with persistent atrial fibrillation.\",\"authors\":\"Yalin Lu, Liang Ma, Jian Yang, Xinyang Jin, Tao Wang, Jing Gao, Yawen Li, Ni Zhang, Qingxiong Yue, Shijun Li\",\"doi\":\"10.1111/pace.15054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Global longitudinal strain (GLS) and atrial voltage are acknowledged markers for worse rhythm outcome after ablation of persistent atrial fibrillation (PeAF). The majority of research efforts have been directed towards the left atrium (LA), with relatively fewer studies focusing on the right atrium (RA). The aim of this study was to investigate the effect of the biatrial substrate on the outcome following radiofrequency catheter ablation (RFCA).</p><p><strong>Methods: </strong>All patients underwent two-dimensional speckle tracking echocardiography (2D-STE) and high-density mapping (HDM) on LA and RA in preoperative and postoperative stages of RFCA. Atrial substrate was assessed by GLS, average voltage, and low voltage zone (LVZ).</p><p><strong>Results: </strong>This retrospective study enrolled 48 patients. With a follow-up of 385.98 ± 161.78 days, 22.92% (11/48) of all patients had AF recurrence and 63.64% in low strain group. Left atrial-low voltage zone (LA-LVZ) prior to RFCA was 67.52 ± 15.27% and 54.21 ± 20.07%, respectively, in the recurrence group and non-recurrence group. Multivariate regression analysis showed that preoperative LA-GLS (OR 0.047, 95%CI 0.002-0.941, p = .046) was independent predictors of AF recurrence. Biatrial average voltage in preoperative and postoperative stages were positively correlated (preoperative: r = 0.563 p < .001; postoperative: r = 0.464 p = .002). There was no significant difference in the proportion of RA in the recurrence group except the septum in preoperative and postoperative stages.</p><p><strong>Conclusions: </strong>Low LA-GLS and high LA-LVZ may be predictors of RFCA recurrence in PeAF patients. Biatrial average voltage were positively correlated in preoperative and postoperative stages.</p>\",\"PeriodicalId\":54653,\"journal\":{\"name\":\"Pace-Pacing and Clinical Electrophysiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-08-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pace-Pacing and Clinical Electrophysiology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.15054\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15054","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Relationships between biatrial substrate and recurrence after radiofrequency ablation in patients with persistent atrial fibrillation.
Background: Global longitudinal strain (GLS) and atrial voltage are acknowledged markers for worse rhythm outcome after ablation of persistent atrial fibrillation (PeAF). The majority of research efforts have been directed towards the left atrium (LA), with relatively fewer studies focusing on the right atrium (RA). The aim of this study was to investigate the effect of the biatrial substrate on the outcome following radiofrequency catheter ablation (RFCA).
Methods: All patients underwent two-dimensional speckle tracking echocardiography (2D-STE) and high-density mapping (HDM) on LA and RA in preoperative and postoperative stages of RFCA. Atrial substrate was assessed by GLS, average voltage, and low voltage zone (LVZ).
Results: This retrospective study enrolled 48 patients. With a follow-up of 385.98 ± 161.78 days, 22.92% (11/48) of all patients had AF recurrence and 63.64% in low strain group. Left atrial-low voltage zone (LA-LVZ) prior to RFCA was 67.52 ± 15.27% and 54.21 ± 20.07%, respectively, in the recurrence group and non-recurrence group. Multivariate regression analysis showed that preoperative LA-GLS (OR 0.047, 95%CI 0.002-0.941, p = .046) was independent predictors of AF recurrence. Biatrial average voltage in preoperative and postoperative stages were positively correlated (preoperative: r = 0.563 p < .001; postoperative: r = 0.464 p = .002). There was no significant difference in the proportion of RA in the recurrence group except the septum in preoperative and postoperative stages.
Conclusions: Low LA-GLS and high LA-LVZ may be predictors of RFCA recurrence in PeAF patients. Biatrial average voltage were positively correlated in preoperative and postoperative stages.
期刊介绍:
Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.