Laura Büttner, Lisa Pick, Martin Jonczyk, Uli Fehrenbach, Federico Collettini, Timo Alexander Auer, Dirk Schnapauff, Maximilian De Bucourt, Gero Wieners, Bernhard Gebauer, Annette Aigner, Georg Böning
{"title":"门静脉高压症患者经颈静脉肝内门体分流术(TIPS)后的分流功能障碍和死亡率。","authors":"Laura Büttner, Lisa Pick, Martin Jonczyk, Uli Fehrenbach, Federico Collettini, Timo Alexander Auer, Dirk Schnapauff, Maximilian De Bucourt, Gero Wieners, Bernhard Gebauer, Annette Aigner, Georg Böning","doi":"10.1186/s13244-024-01768-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Transjugular intrahepatic portosystemic shunt (TIPS) is a catheter-based, minimally invasive procedure to reduce portal hypertension. The aim of the study was to investigate dysfunction and mortality after TIPS and to identify factors associated with these events.</p><p><strong>Methods: </strong>A retrospective analysis of 834 patients undergoing TIPS implantation in a single center from 1993-2018 was performed. Cumulative incidence curves were estimated, and frailty models were used to assess associations between potentially influential variables and time to dysfunction or death.</p><p><strong>Results: </strong>1-, 2-, and 5-year mortality rates were 20.9% (confidence interval (CI) 17.7-24.1), 22.5% (CI 19.1-25.8), and 25.0% (CI: 21.1-28.8), 1-year, 2-year, and 5-year dysfunction rates were 28.4% (CI 24.6-32.3), 38.9% (CI 34.5-43.3), and 52.4% (CI 47.2-57.6). The use of covered stents is a protective factor regarding TIPS dysfunction (hazard ratio (HR) 0.47, CI 0.33-0.68) but does not play a major role in survival (HR 0.95, CI 0.58-1.56). Risk factors for mortality are rather TIPS in an emergency setting (HR 2.78, CI 1.19-6.50), a previous TIPS dysfunction (HR 2.43, CI 1.28-4.62), and an increased Freiburg score (HR 1.45, CI 0.93-2.28).</p><p><strong>Conclusion: </strong>The use of covered stents is an important protective factor regarding TIPS dysfunction. Whereas previous TIPS dysfunction, emergency TIPS implantation, and an elevated Freiburg score are associated with increased mortality. Awareness of risk factors could contribute to a better selection of patients who may benefit from a TIPS procedure and improve clinical follow-up with regard to early detection of thrombosis/stenosis.</p><p><strong>Critical relevance statement: </strong>The use of covered stents reduces the risk of dysfunction after transjugular intrahepatic portosystemic shunt (TIPS). TIPS dysfunction, emergency TIPS placement, and a high Freiburg score are linked to higher mortality rates in TIPS patients.</p><p><strong>Key points: </strong>The risk of dysfunction is higher for uncovered stents compared to covered stents. Transjugular intrahepatic portosystemic shunt dysfunction increases the risk of instantaneous death after the intervention. A higher Freiburg score increases the rate of death after the intervention. Transjugular intrahepatic portosystemic shunt implantations in emergency settings reduce survival rates.</p>","PeriodicalId":13639,"journal":{"name":"Insights into Imaging","volume":"15 1","pages":"193"},"PeriodicalIF":4.1000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11306489/pdf/","citationCount":"0","resultStr":"{\"title\":\"Shunt dysfunction and mortality after transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension.\",\"authors\":\"Laura Büttner, Lisa Pick, Martin Jonczyk, Uli Fehrenbach, Federico Collettini, Timo Alexander Auer, Dirk Schnapauff, Maximilian De Bucourt, Gero Wieners, Bernhard Gebauer, Annette Aigner, Georg Böning\",\"doi\":\"10.1186/s13244-024-01768-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Transjugular intrahepatic portosystemic shunt (TIPS) is a catheter-based, minimally invasive procedure to reduce portal hypertension. The aim of the study was to investigate dysfunction and mortality after TIPS and to identify factors associated with these events.</p><p><strong>Methods: </strong>A retrospective analysis of 834 patients undergoing TIPS implantation in a single center from 1993-2018 was performed. Cumulative incidence curves were estimated, and frailty models were used to assess associations between potentially influential variables and time to dysfunction or death.</p><p><strong>Results: </strong>1-, 2-, and 5-year mortality rates were 20.9% (confidence interval (CI) 17.7-24.1), 22.5% (CI 19.1-25.8), and 25.0% (CI: 21.1-28.8), 1-year, 2-year, and 5-year dysfunction rates were 28.4% (CI 24.6-32.3), 38.9% (CI 34.5-43.3), and 52.4% (CI 47.2-57.6). The use of covered stents is a protective factor regarding TIPS dysfunction (hazard ratio (HR) 0.47, CI 0.33-0.68) but does not play a major role in survival (HR 0.95, CI 0.58-1.56). Risk factors for mortality are rather TIPS in an emergency setting (HR 2.78, CI 1.19-6.50), a previous TIPS dysfunction (HR 2.43, CI 1.28-4.62), and an increased Freiburg score (HR 1.45, CI 0.93-2.28).</p><p><strong>Conclusion: </strong>The use of covered stents is an important protective factor regarding TIPS dysfunction. Whereas previous TIPS dysfunction, emergency TIPS implantation, and an elevated Freiburg score are associated with increased mortality. Awareness of risk factors could contribute to a better selection of patients who may benefit from a TIPS procedure and improve clinical follow-up with regard to early detection of thrombosis/stenosis.</p><p><strong>Critical relevance statement: </strong>The use of covered stents reduces the risk of dysfunction after transjugular intrahepatic portosystemic shunt (TIPS). TIPS dysfunction, emergency TIPS placement, and a high Freiburg score are linked to higher mortality rates in TIPS patients.</p><p><strong>Key points: </strong>The risk of dysfunction is higher for uncovered stents compared to covered stents. Transjugular intrahepatic portosystemic shunt dysfunction increases the risk of instantaneous death after the intervention. A higher Freiburg score increases the rate of death after the intervention. Transjugular intrahepatic portosystemic shunt implantations in emergency settings reduce survival rates.</p>\",\"PeriodicalId\":13639,\"journal\":{\"name\":\"Insights into Imaging\",\"volume\":\"15 1\",\"pages\":\"193\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11306489/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Insights into Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13244-024-01768-8\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Insights into Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13244-024-01768-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Shunt dysfunction and mortality after transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension.
Objectives: Transjugular intrahepatic portosystemic shunt (TIPS) is a catheter-based, minimally invasive procedure to reduce portal hypertension. The aim of the study was to investigate dysfunction and mortality after TIPS and to identify factors associated with these events.
Methods: A retrospective analysis of 834 patients undergoing TIPS implantation in a single center from 1993-2018 was performed. Cumulative incidence curves were estimated, and frailty models were used to assess associations between potentially influential variables and time to dysfunction or death.
Results: 1-, 2-, and 5-year mortality rates were 20.9% (confidence interval (CI) 17.7-24.1), 22.5% (CI 19.1-25.8), and 25.0% (CI: 21.1-28.8), 1-year, 2-year, and 5-year dysfunction rates were 28.4% (CI 24.6-32.3), 38.9% (CI 34.5-43.3), and 52.4% (CI 47.2-57.6). The use of covered stents is a protective factor regarding TIPS dysfunction (hazard ratio (HR) 0.47, CI 0.33-0.68) but does not play a major role in survival (HR 0.95, CI 0.58-1.56). Risk factors for mortality are rather TIPS in an emergency setting (HR 2.78, CI 1.19-6.50), a previous TIPS dysfunction (HR 2.43, CI 1.28-4.62), and an increased Freiburg score (HR 1.45, CI 0.93-2.28).
Conclusion: The use of covered stents is an important protective factor regarding TIPS dysfunction. Whereas previous TIPS dysfunction, emergency TIPS implantation, and an elevated Freiburg score are associated with increased mortality. Awareness of risk factors could contribute to a better selection of patients who may benefit from a TIPS procedure and improve clinical follow-up with regard to early detection of thrombosis/stenosis.
Critical relevance statement: The use of covered stents reduces the risk of dysfunction after transjugular intrahepatic portosystemic shunt (TIPS). TIPS dysfunction, emergency TIPS placement, and a high Freiburg score are linked to higher mortality rates in TIPS patients.
Key points: The risk of dysfunction is higher for uncovered stents compared to covered stents. Transjugular intrahepatic portosystemic shunt dysfunction increases the risk of instantaneous death after the intervention. A higher Freiburg score increases the rate of death after the intervention. Transjugular intrahepatic portosystemic shunt implantations in emergency settings reduce survival rates.
期刊介绍:
Insights into Imaging (I³) is a peer-reviewed open access journal published under the brand SpringerOpen. All content published in the journal is freely available online to anyone, anywhere!
I³ continuously updates scientific knowledge and progress in best-practice standards in radiology through the publication of original articles and state-of-the-art reviews and opinions, along with recommendations and statements from the leading radiological societies in Europe.
Founded by the European Society of Radiology (ESR), I³ creates a platform for educational material, guidelines and recommendations, and a forum for topics of controversy.
A balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes I³ an indispensable source for current information in this field.
I³ is owned by the ESR, however authors retain copyright to their article according to the Creative Commons Attribution License (see Copyright and License Agreement). All articles can be read, redistributed and reused for free, as long as the author of the original work is cited properly.
The open access fees (article-processing charges) for this journal are kindly sponsored by ESR for all Members.
The journal went open access in 2012, which means that all articles published since then are freely available online.