利用超高频换能器对小鼠模型的正常肾脏和纤维化肾脏进行全面超声评估。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-09-01 Epub Date: 2024-06-21 DOI:10.14366/usg.24024
Myoung Seok Lee, Jeong Yeon Cho, Min Hoan Moon, Jeonghwan Lee, Jung Pyo Lee, Nayeon Shin, Wencheng Jin, Ara Cho
{"title":"利用超高频换能器对小鼠模型的正常肾脏和纤维化肾脏进行全面超声评估。","authors":"Myoung Seok Lee, Jeong Yeon Cho, Min Hoan Moon, Jeonghwan Lee, Jung Pyo Lee, Nayeon Shin, Wencheng Jin, Ara Cho","doi":"10.14366/usg.24024","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to establish baseline morphological and functional data for normal mouse kidneys via a clinical 33 MHz ultra-high-frequency (UHF) transducer, compare the data with the findings from fibrotic mice, and assess correlations between ultrasonography (US) parameters and fibrosis-related markers.</p><p><strong>Methods: </strong>This retrospective study aggregated data from three separate experiments (obstructive nephropathy, diabetic nephropathy, and acute-to-chronic kidney injury models). Morphological parameters (kidney size, parenchymal thickness [PT]) and functional (shear-wave speed [SWS], stiffness, resistive index [RI], and microvascular imaging-derived vascular index [VI]) were assessed and compared between normal and fibrotic mouse kidneys. Semi-quantitative histopathologic scores were calculated and molecular markers (epithelial cadherin), Collagen 1A1 [Col1A1], transforming growth factor-β, and α-smooth muscle actin [α-SMA]) were evaluated using western blots. Correlations with US parameters were explored.</p><p><strong>Results: </strong>Clinical UHF US successfully imaged the kidneys of the experimental mice. A three-layer configuration was prevalent in the normal mouse kidney parenchyma (34/35) but was blurred in most fibrotic mouse kidneys (33/40). US parameters, including size (11.14 vs. 10.70 mm), PT (2.07 vs. 1.24 mm), RI (0.64 vs. 0.77), VI (22.55% vs. 11.47%, only for non-obstructive kidneys), SWS (1.67 vs. 2.06 m/s), and stiffness (8.23 vs. 12.92 kPa), showed significant differences between normal and fibrotic kidneys (P&lt;0.001). These parameters also demonstrated strong discriminative ability in receiver operating characteristic curve analysis (area under the curve, 0.76 to 0.95; P&lt;0.001). PT, VI, and RI were significantly correlated with histological fibrosis markers (ρ=-0.64 to -0.68 for PT and VI, ρ=0.71-0.76 for RI, P&lt;0.001). VI exhibited strong negative correlations with Col1A1 (ρ=-0.76, P=0.006) and α-SMA (ρ=-0.75, P=0.009).</p><p><strong>Conclusion: </strong>Clinical UHF US effectively distinguished normal and fibrotic mouse kidneys, indicating the potential of US parameters, notably VI, as noninvasive markers for tracking fibrosis initiation and progression in mouse kidney fibrosis models.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374587/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comprehensive ultrasonographic evaluation of normal and fibrotic kidneys in a mouse model with an ultra-high-frequency transducer.\",\"authors\":\"Myoung Seok Lee, Jeong Yeon Cho, Min Hoan Moon, Jeonghwan Lee, Jung Pyo Lee, Nayeon Shin, Wencheng Jin, Ara Cho\",\"doi\":\"10.14366/usg.24024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to establish baseline morphological and functional data for normal mouse kidneys via a clinical 33 MHz ultra-high-frequency (UHF) transducer, compare the data with the findings from fibrotic mice, and assess correlations between ultrasonography (US) parameters and fibrosis-related markers.</p><p><strong>Methods: </strong>This retrospective study aggregated data from three separate experiments (obstructive nephropathy, diabetic nephropathy, and acute-to-chronic kidney injury models). Morphological parameters (kidney size, parenchymal thickness [PT]) and functional (shear-wave speed [SWS], stiffness, resistive index [RI], and microvascular imaging-derived vascular index [VI]) were assessed and compared between normal and fibrotic mouse kidneys. Semi-quantitative histopathologic scores were calculated and molecular markers (epithelial cadherin), Collagen 1A1 [Col1A1], transforming growth factor-β, and α-smooth muscle actin [α-SMA]) were evaluated using western blots. Correlations with US parameters were explored.</p><p><strong>Results: </strong>Clinical UHF US successfully imaged the kidneys of the experimental mice. A three-layer configuration was prevalent in the normal mouse kidney parenchyma (34/35) but was blurred in most fibrotic mouse kidneys (33/40). US parameters, including size (11.14 vs. 10.70 mm), PT (2.07 vs. 1.24 mm), RI (0.64 vs. 0.77), VI (22.55% vs. 11.47%, only for non-obstructive kidneys), SWS (1.67 vs. 2.06 m/s), and stiffness (8.23 vs. 12.92 kPa), showed significant differences between normal and fibrotic kidneys (P&lt;0.001). These parameters also demonstrated strong discriminative ability in receiver operating characteristic curve analysis (area under the curve, 0.76 to 0.95; P&lt;0.001). PT, VI, and RI were significantly correlated with histological fibrosis markers (ρ=-0.64 to -0.68 for PT and VI, ρ=0.71-0.76 for RI, P&lt;0.001). VI exhibited strong negative correlations with Col1A1 (ρ=-0.76, P=0.006) and α-SMA (ρ=-0.75, P=0.009).</p><p><strong>Conclusion: </strong>Clinical UHF US effectively distinguished normal and fibrotic mouse kidneys, indicating the potential of US parameters, notably VI, as noninvasive markers for tracking fibrosis initiation and progression in mouse kidney fibrosis models.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374587/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.14366/usg.24024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14366/usg.24024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在通过临床 33 MHz 超高频(UHF)换能器建立正常小鼠肾脏的基线形态和功能数据,将这些数据与纤维化小鼠的研究结果进行比较,并评估超声造影(US)参数与纤维化相关标记物之间的相关性:这项回顾性研究汇总了三个独立实验(阻塞性肾病、糖尿病肾病和急性至慢性肾损伤模型)的数据。对形态参数(肾脏大小、实质厚度[PT])和功能参数(剪切波速度[SWS]、硬度、电阻指数[RI]和微血管成像衍生血管指数[VI])进行了评估,并对正常肾脏和纤维化小鼠肾脏进行了比较。计算半定量组织病理学评分,并使用 Western 印迹法评估分子标记物(上皮凝集素)、胶原 1A1 [Col1A1]、转化生长因子-β 和 α 平滑肌肌动蛋白 [α-SMA])。结果:结果:临床超高频 US 成功地对实验小鼠的肾脏进行了成像。正常小鼠肾实质中普遍存在三层结构(34/35),但在大多数纤维化小鼠肾脏(33/40)中却很模糊。US参数,包括大小(11.14 vs. 10.70 mm)、PT(2.07 vs. 1.24 mm)、RI(0.64 vs. 0.77)、VI(22.55% vs. 11.47%,仅针对非梗阻性肾脏)、SWS(1.67 vs. 2.06 m/s)和硬度(8.23 vs. 12.92 kPa)在正常肾脏和纤维化肾脏之间存在显著差异(P<0.001)。在接收者操作特征曲线分析中,这些参数也显示出很强的鉴别能力(曲线下面积,0.76 至 0.95;P<0.001)。PT、VI 和 RI 与组织学纤维化标记物有显著相关性(PT 和 VI 的 ρ=-0.64 至 -0.68,RI 的 ρ=0.71 至 0.76,P<0.001)。VI与Col1A1(ρ=-0.76,P=0.006)和α-SMA(ρ=-0.75,P=0.009)呈强负相关:结论:临床超高频 US 能有效区分正常肾脏和纤维化小鼠肾脏,这表明 US 参数(尤其是 VI)有可能成为追踪小鼠肾脏纤维化模型中纤维化发生和发展的无创标记物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comprehensive ultrasonographic evaluation of normal and fibrotic kidneys in a mouse model with an ultra-high-frequency transducer.

Purpose: This study aimed to establish baseline morphological and functional data for normal mouse kidneys via a clinical 33 MHz ultra-high-frequency (UHF) transducer, compare the data with the findings from fibrotic mice, and assess correlations between ultrasonography (US) parameters and fibrosis-related markers.

Methods: This retrospective study aggregated data from three separate experiments (obstructive nephropathy, diabetic nephropathy, and acute-to-chronic kidney injury models). Morphological parameters (kidney size, parenchymal thickness [PT]) and functional (shear-wave speed [SWS], stiffness, resistive index [RI], and microvascular imaging-derived vascular index [VI]) were assessed and compared between normal and fibrotic mouse kidneys. Semi-quantitative histopathologic scores were calculated and molecular markers (epithelial cadherin), Collagen 1A1 [Col1A1], transforming growth factor-β, and α-smooth muscle actin [α-SMA]) were evaluated using western blots. Correlations with US parameters were explored.

Results: Clinical UHF US successfully imaged the kidneys of the experimental mice. A three-layer configuration was prevalent in the normal mouse kidney parenchyma (34/35) but was blurred in most fibrotic mouse kidneys (33/40). US parameters, including size (11.14 vs. 10.70 mm), PT (2.07 vs. 1.24 mm), RI (0.64 vs. 0.77), VI (22.55% vs. 11.47%, only for non-obstructive kidneys), SWS (1.67 vs. 2.06 m/s), and stiffness (8.23 vs. 12.92 kPa), showed significant differences between normal and fibrotic kidneys (P<0.001). These parameters also demonstrated strong discriminative ability in receiver operating characteristic curve analysis (area under the curve, 0.76 to 0.95; P<0.001). PT, VI, and RI were significantly correlated with histological fibrosis markers (ρ=-0.64 to -0.68 for PT and VI, ρ=0.71-0.76 for RI, P<0.001). VI exhibited strong negative correlations with Col1A1 (ρ=-0.76, P=0.006) and α-SMA (ρ=-0.75, P=0.009).

Conclusion: Clinical UHF US effectively distinguished normal and fibrotic mouse kidneys, indicating the potential of US parameters, notably VI, as noninvasive markers for tracking fibrosis initiation and progression in mouse kidney fibrosis models.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1