在光固化过程中,保护衬垫和玻璃离聚物在控制牙髓温度方面的作用。

Vanessa-Dias-Barboza Munhoz, Mateus-Garcia Rocha, Americo-Bortolazzo Correr, Mario-Alexandre-Coelho Sinhoreti, Saulo Geraldeli, Dayane Oliveira
{"title":"在光固化过程中,保护衬垫和玻璃离聚物在控制牙髓温度方面的作用。","authors":"Vanessa-Dias-Barboza Munhoz, Mateus-Garcia Rocha, Americo-Bortolazzo Correr, Mario-Alexandre-Coelho Sinhoreti, Saulo Geraldeli, Dayane Oliveira","doi":"10.4317/jced.61703","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To evaluate the thermal insulation of protective liners and glass ionomer cement during light-curing procedures.</p><p><strong>Material and methods: </strong>Human third molars underwent Class I preparations with dimensions 5 mm long × 4 mm wide × 4 mm deep in a standardized manner ensured a consistent ±0.5 mm dentin thickness at the pulpal floor. The teeth were attached to a customized oral cavity chamber simulator with a circulating bath at a standardized temperature of 34.2 ± 1oC. The temperature variations at the pulpal floor were captured in real-time by video using an infrared thermal camera (FLIR ONE Pro, FLIR Systems). The materials evaluated were: Dycal (Dentsply), TheraCal LC (Bisco), Activa (Pulpdent), and Fuji II LC (GC). All light-activation procedures were performed with the same light-curing unit (Valo Grand, Ultradent) in standard mode, 1000 mW/cm2, and time of exposure following manufacturer instructions. A power analysis was conducted to determine the sample size considering a minimal power of 0.8, with α=0.05. Statistical analyses were performed using ANOVA and Tukey's test for multiple comparisons.</p><p><strong>Results: </strong>The temperature at the pulpal floor increased above the 5.5 ºC safety threshold difference for clinical scenarios tested. None of the materials provided proper thermal insulation for light-curing procedures (<i>p</i> = 0.25). The higher the number of light-cured steps, the longer the pulp remained above the 5.5 ºC temperature threshold.</p><p><strong>Conclusions: </strong>The materials tested provided improper thermal insulation (Δ > 5.5 ºC). Thus, prolonged or multiple light-curing exposures can be harmful to the pulp tissues. Therefore, for indirect pulpal capping procedures, self-cured materials or a reduced number of steps requiring light curing must be adopted to reduce the amount of time the pulp remains above the 5.5 ºC safety temperature threshold. <b>Key words:</b>Dental Pulp Capping, Calcium hydroxide, Bioactive, Thermal Damage.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"16 6","pages":"e749-e754"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310984/pdf/","citationCount":"0","resultStr":"{\"title\":\"The role of protective liners and glass ionomer in managing pulp temperature during light curing.\",\"authors\":\"Vanessa-Dias-Barboza Munhoz, Mateus-Garcia Rocha, Americo-Bortolazzo Correr, Mario-Alexandre-Coelho Sinhoreti, Saulo Geraldeli, Dayane Oliveira\",\"doi\":\"10.4317/jced.61703\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To evaluate the thermal insulation of protective liners and glass ionomer cement during light-curing procedures.</p><p><strong>Material and methods: </strong>Human third molars underwent Class I preparations with dimensions 5 mm long × 4 mm wide × 4 mm deep in a standardized manner ensured a consistent ±0.5 mm dentin thickness at the pulpal floor. The teeth were attached to a customized oral cavity chamber simulator with a circulating bath at a standardized temperature of 34.2 ± 1oC. The temperature variations at the pulpal floor were captured in real-time by video using an infrared thermal camera (FLIR ONE Pro, FLIR Systems). The materials evaluated were: Dycal (Dentsply), TheraCal LC (Bisco), Activa (Pulpdent), and Fuji II LC (GC). All light-activation procedures were performed with the same light-curing unit (Valo Grand, Ultradent) in standard mode, 1000 mW/cm2, and time of exposure following manufacturer instructions. A power analysis was conducted to determine the sample size considering a minimal power of 0.8, with α=0.05. Statistical analyses were performed using ANOVA and Tukey's test for multiple comparisons.</p><p><strong>Results: </strong>The temperature at the pulpal floor increased above the 5.5 ºC safety threshold difference for clinical scenarios tested. None of the materials provided proper thermal insulation for light-curing procedures (<i>p</i> = 0.25). The higher the number of light-cured steps, the longer the pulp remained above the 5.5 ºC temperature threshold.</p><p><strong>Conclusions: </strong>The materials tested provided improper thermal insulation (Δ > 5.5 ºC). Thus, prolonged or multiple light-curing exposures can be harmful to the pulp tissues. Therefore, for indirect pulpal capping procedures, self-cured materials or a reduced number of steps requiring light curing must be adopted to reduce the amount of time the pulp remains above the 5.5 ºC safety temperature threshold. <b>Key words:</b>Dental Pulp Capping, Calcium hydroxide, Bioactive, Thermal Damage.</p>\",\"PeriodicalId\":15376,\"journal\":{\"name\":\"Journal of Clinical and Experimental Dentistry\",\"volume\":\"16 6\",\"pages\":\"e749-e754\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310984/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical and Experimental Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4317/jced.61703\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.61703","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:材料和方法:对人类第三磨牙进行 I 类预备,其尺寸为长 5 mm × 宽 4 mm × 深 4 mm,以标准化方式确保牙髓底层的牙本质厚度一致,即 ±0.5 mm。牙齿被固定在一个定制的口腔腔室模拟器上,该模拟器带有一个循环浴槽,标准温度为 34.2 ± 1oC。使用红外热像仪(FLIR ONE Pro,FLIR Systems)通过视频实时捕捉牙髓底部的温度变化。评估的材料有Dycal (Dentsply)、TheraCal LC (Bisco)、Activa (Pulpdent) 和 Fuji II LC (GC)。所有光激活程序均使用同一台光固化设备(Valo Grand,Ultradent)在标准模式、1000 mW/cm2、曝光时间下按照制造商的说明进行。考虑到最小功率为 0.8,α=0.05,进行了功率分析以确定样本量。统计分析采用方差分析和 Tukey's 检验进行多重比较:结果:在临床测试中,牙髓底部的温度升高超过了 5.5 ºC 的安全阈值。没有一种材料能为光固化程序提供适当的隔热效果(p = 0.25)。光固化步骤越多,牙髓保持在 5.5 ºC 温度阈值以上的时间越长:测试材料的隔热性能不佳(Δ > 5.5 ºC)。因此,长时间或多次光固化会对牙髓组织造成伤害。因此,在牙髓间接盖髓术中,必须采用自固化材料或减少光固化步骤,以减少牙髓在 5.5 ºC 安全温度阈值以上停留的时间。关键词:牙髓封顶 氢氧化钙 生物活性 热损伤
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The role of protective liners and glass ionomer in managing pulp temperature during light curing.

Background: To evaluate the thermal insulation of protective liners and glass ionomer cement during light-curing procedures.

Material and methods: Human third molars underwent Class I preparations with dimensions 5 mm long × 4 mm wide × 4 mm deep in a standardized manner ensured a consistent ±0.5 mm dentin thickness at the pulpal floor. The teeth were attached to a customized oral cavity chamber simulator with a circulating bath at a standardized temperature of 34.2 ± 1oC. The temperature variations at the pulpal floor were captured in real-time by video using an infrared thermal camera (FLIR ONE Pro, FLIR Systems). The materials evaluated were: Dycal (Dentsply), TheraCal LC (Bisco), Activa (Pulpdent), and Fuji II LC (GC). All light-activation procedures were performed with the same light-curing unit (Valo Grand, Ultradent) in standard mode, 1000 mW/cm2, and time of exposure following manufacturer instructions. A power analysis was conducted to determine the sample size considering a minimal power of 0.8, with α=0.05. Statistical analyses were performed using ANOVA and Tukey's test for multiple comparisons.

Results: The temperature at the pulpal floor increased above the 5.5 ºC safety threshold difference for clinical scenarios tested. None of the materials provided proper thermal insulation for light-curing procedures (p = 0.25). The higher the number of light-cured steps, the longer the pulp remained above the 5.5 ºC temperature threshold.

Conclusions: The materials tested provided improper thermal insulation (Δ > 5.5 ºC). Thus, prolonged or multiple light-curing exposures can be harmful to the pulp tissues. Therefore, for indirect pulpal capping procedures, self-cured materials or a reduced number of steps requiring light curing must be adopted to reduce the amount of time the pulp remains above the 5.5 ºC safety temperature threshold. Key words:Dental Pulp Capping, Calcium hydroxide, Bioactive, Thermal Damage.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
118
期刊介绍: Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery
期刊最新文献
Surface Integrity of Widely Used Resin-Modified Glass Ionomers: New Findings Amid Limited Scientific Literature. Ultrasonic Cavity Preparation with CVD Diamond Tips: A Scanning Electron Microscopy Study of Dentin Surface Morphology and Smear Layer Formation. Masking ability of layering techniques combined with white or yellow opaquers on a dark background. Effect of Apical Third Enlargement to Different Preparation Sizes and Tapers on Postoperative Pain and Intra-canal Bacterial Reduction: A Randomized Clinical Trial. Evaluation of Accuracy and Reproducibility of an AI-Based Cephalometric Landmark Detection Software: A Comparative Study with Manual Annotations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1