Wei Zhen, Farah Sheikh, Dwayne A Breining, Gregory J Berry
{"title":"利用样本对答平台快速诊断单纯疱疹病毒 1 和 2 血流感染。","authors":"Wei Zhen, Farah Sheikh, Dwayne A Breining, Gregory J Berry","doi":"10.1128/jcm.00131-24","DOIUrl":null,"url":null,"abstract":"<p><p>Bloodstream HSV-1 and HSV-2 infections can cause devastating outcomes with high morbidity and mortality, especially in neonates or immunocompromised individuals. Proper patient management for herpes simplex virus (HSV) bloodstream infections is time-sensitive and requires a rapid, accurate, and definitive diagnosis. The absence of the U.S. Food and Drug Administration (FDA)-approved molecular assays for HSV detection in blood, coupled with a lack of consensus on the optimal sample type, underscores the unmet need for improved diagnostics. We prospectively compared the cycle threshold values in paired samples including whole blood (WB), plasma, serum, and peripheral blood mononuclear cells (PBMCs) from patients with bloodstream HSV infections. This analysis employed a modified use of the FDA-cleared Simplexa HSV-1 & 2 Direct assay. The clinical performance in serum was assessed by comparing the results of 247 remnant specimens on this sample-to-answer platform to established laboratory-developed tests in a blinded fashion. Serum samples exhibited significantly lower cycle thresholds than whole blood samples [2.6 cycle threshold (Ct) bias, <i>P</i> < 0.001]. The modified Simplexa assay demonstrated 100% positive percent agreement for the detection of HSV-1 and HSV-2 DNA in serum samples and yielded an overall agreement of 95% (95% CI, 0.92 to 0.97), with a κ statistic of 0.75 (95% CI, 0.62 to 0.86) compared to the composite reference method. Discordance rates were 5.20% for HSV-1 and 0.81% for HSV-2. This investigation demonstrates that serum is an optimal specimen type for HSV detection when compared to several blood compartments. Serum offers a promising sample type for rapid and accurate diagnosis of HSV bloodstream infections using the modified Simplexa assay.</p><p><strong>Importance: </strong>Rapid, accurate, and definitive diagnosis of herpes simplex virus (HSV) infections is crucial in clinical settings for patient management. The absence of FDA-authorized molecular assays for HSV-1/2 detection in blood, coupled with a lack of consensus on the optimal sample type, underscores the need for improved diagnostic methods. Furthermore, rapid diagnosis of HSV bloodstream infections enables timely administration of antiviral treatment, influences patient management decisions for those at high risk, and can contribute to shorter hospital stays, thereby reducing healthcare costs.</p>","PeriodicalId":15511,"journal":{"name":"Journal of Clinical Microbiology","volume":" ","pages":"e0013124"},"PeriodicalIF":6.1000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11389144/pdf/","citationCount":"0","resultStr":"{\"title\":\"Rapid diagnosis of herpes simplex virus 1 and 2 bloodstream infections utilizing a sample-to-answer platform.\",\"authors\":\"Wei Zhen, Farah Sheikh, Dwayne A Breining, Gregory J Berry\",\"doi\":\"10.1128/jcm.00131-24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Bloodstream HSV-1 and HSV-2 infections can cause devastating outcomes with high morbidity and mortality, especially in neonates or immunocompromised individuals. Proper patient management for herpes simplex virus (HSV) bloodstream infections is time-sensitive and requires a rapid, accurate, and definitive diagnosis. The absence of the U.S. Food and Drug Administration (FDA)-approved molecular assays for HSV detection in blood, coupled with a lack of consensus on the optimal sample type, underscores the unmet need for improved diagnostics. We prospectively compared the cycle threshold values in paired samples including whole blood (WB), plasma, serum, and peripheral blood mononuclear cells (PBMCs) from patients with bloodstream HSV infections. This analysis employed a modified use of the FDA-cleared Simplexa HSV-1 & 2 Direct assay. The clinical performance in serum was assessed by comparing the results of 247 remnant specimens on this sample-to-answer platform to established laboratory-developed tests in a blinded fashion. Serum samples exhibited significantly lower cycle thresholds than whole blood samples [2.6 cycle threshold (Ct) bias, <i>P</i> < 0.001]. The modified Simplexa assay demonstrated 100% positive percent agreement for the detection of HSV-1 and HSV-2 DNA in serum samples and yielded an overall agreement of 95% (95% CI, 0.92 to 0.97), with a κ statistic of 0.75 (95% CI, 0.62 to 0.86) compared to the composite reference method. Discordance rates were 5.20% for HSV-1 and 0.81% for HSV-2. This investigation demonstrates that serum is an optimal specimen type for HSV detection when compared to several blood compartments. Serum offers a promising sample type for rapid and accurate diagnosis of HSV bloodstream infections using the modified Simplexa assay.</p><p><strong>Importance: </strong>Rapid, accurate, and definitive diagnosis of herpes simplex virus (HSV) infections is crucial in clinical settings for patient management. The absence of FDA-authorized molecular assays for HSV-1/2 detection in blood, coupled with a lack of consensus on the optimal sample type, underscores the need for improved diagnostic methods. Furthermore, rapid diagnosis of HSV bloodstream infections enables timely administration of antiviral treatment, influences patient management decisions for those at high risk, and can contribute to shorter hospital stays, thereby reducing healthcare costs.</p>\",\"PeriodicalId\":15511,\"journal\":{\"name\":\"Journal of Clinical Microbiology\",\"volume\":\" \",\"pages\":\"e0013124\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11389144/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Microbiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1128/jcm.00131-24\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Microbiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1128/jcm.00131-24","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MICROBIOLOGY","Score":null,"Total":0}
Rapid diagnosis of herpes simplex virus 1 and 2 bloodstream infections utilizing a sample-to-answer platform.
Bloodstream HSV-1 and HSV-2 infections can cause devastating outcomes with high morbidity and mortality, especially in neonates or immunocompromised individuals. Proper patient management for herpes simplex virus (HSV) bloodstream infections is time-sensitive and requires a rapid, accurate, and definitive diagnosis. The absence of the U.S. Food and Drug Administration (FDA)-approved molecular assays for HSV detection in blood, coupled with a lack of consensus on the optimal sample type, underscores the unmet need for improved diagnostics. We prospectively compared the cycle threshold values in paired samples including whole blood (WB), plasma, serum, and peripheral blood mononuclear cells (PBMCs) from patients with bloodstream HSV infections. This analysis employed a modified use of the FDA-cleared Simplexa HSV-1 & 2 Direct assay. The clinical performance in serum was assessed by comparing the results of 247 remnant specimens on this sample-to-answer platform to established laboratory-developed tests in a blinded fashion. Serum samples exhibited significantly lower cycle thresholds than whole blood samples [2.6 cycle threshold (Ct) bias, P < 0.001]. The modified Simplexa assay demonstrated 100% positive percent agreement for the detection of HSV-1 and HSV-2 DNA in serum samples and yielded an overall agreement of 95% (95% CI, 0.92 to 0.97), with a κ statistic of 0.75 (95% CI, 0.62 to 0.86) compared to the composite reference method. Discordance rates were 5.20% for HSV-1 and 0.81% for HSV-2. This investigation demonstrates that serum is an optimal specimen type for HSV detection when compared to several blood compartments. Serum offers a promising sample type for rapid and accurate diagnosis of HSV bloodstream infections using the modified Simplexa assay.
Importance: Rapid, accurate, and definitive diagnosis of herpes simplex virus (HSV) infections is crucial in clinical settings for patient management. The absence of FDA-authorized molecular assays for HSV-1/2 detection in blood, coupled with a lack of consensus on the optimal sample type, underscores the need for improved diagnostic methods. Furthermore, rapid diagnosis of HSV bloodstream infections enables timely administration of antiviral treatment, influences patient management decisions for those at high risk, and can contribute to shorter hospital stays, thereby reducing healthcare costs.
期刊介绍:
The Journal of Clinical Microbiology® disseminates the latest research concerning the laboratory diagnosis of human and animal infections, along with the laboratory's role in epidemiology and the management of infectious diseases.