Salim Hamidi, Mina Kahyaie-Aghdam, Mohammad-Esmaeel Ebrahimi-Chaharom, Mahdi Abed-Kahnamouei, Fatemeh Dabaghi-Tabriz
{"title":"掺钕钇钕石榴石(Nd:YAG)激光对使用不同通用粘合剂的超敏牙本质复合树脂微张力粘合强度的影响。","authors":"Salim Hamidi, Mina Kahyaie-Aghdam, Mohammad-Esmaeel Ebrahimi-Chaharom, Mahdi Abed-Kahnamouei, Fatemeh Dabaghi-Tabriz","doi":"10.4317/jced.61493","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to evaluate the effect of the Nd: YAG laser on the tensile bond strength of composite resin to dentin with hypersensitivity using different universal bonding systems.</p><p><strong>Material and methods: </strong>After cutting the crown of 252 molars, buccal cervical enamel was removed at a thickness of approximately 2 mm, and 252 smooth dentin surfaces were exposed. Then they were etched with 0.5 M ethylenediaminetetraacetic acid (pH = 7.4) to stimulate hypersensitivity. The specimens were then randomly divided into 12 groups (n= 21) according to the surface treatments performed. After etching and bonding according to the manufacturer's recommendations in each group, the entire dentin surface was restored with Valux Plus composite resin. The samples were thermocycled and a universal test machine was used to measure the microtensile bond strength. The failure mode for each sample was observed under a stereomicroscope. For data analysis, the Bonferroni test, the independent t-test and the three-way anova test were used.</p><p><strong>Results: </strong>The average microtensile bond strength in non-laser samples was higher than the average in laser samples (<i>P</i><0.001). In comparison with the bonding agent type in both cases with and without laser, the highest average microtensile bond strength was related to ALL-BOND (<i>P</i><0.001), meanwhile the lowest average tensile strength in samples without laser was related to G-Premio universal adhesive (<i>P</i><0.001), and the lowest average microtensile strength in samples with laser belonged to Prime and Bond Elect group (<i>P</i><0.001).</p><p><strong>Conclusions: </strong>Nd: YAG laser irradiation of the dentin surface before applying the adhesive significantly decreased the microtensile bond strength of the composite resin to the dentin surface. <b>Key words:</b>Nd:YAG laser, Bond strength, Dentin, hypersensitivity, Universal adhesives.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"16 6","pages":"e685-e692"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310977/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of the Nd:YAG laser on the micro-tensile bond strength of composite resin to dentin with hypersensitivity using different universal adhesives.\",\"authors\":\"Salim Hamidi, Mina Kahyaie-Aghdam, Mohammad-Esmaeel Ebrahimi-Chaharom, Mahdi Abed-Kahnamouei, Fatemeh Dabaghi-Tabriz\",\"doi\":\"10.4317/jced.61493\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>This study aimed to evaluate the effect of the Nd: YAG laser on the tensile bond strength of composite resin to dentin with hypersensitivity using different universal bonding systems.</p><p><strong>Material and methods: </strong>After cutting the crown of 252 molars, buccal cervical enamel was removed at a thickness of approximately 2 mm, and 252 smooth dentin surfaces were exposed. Then they were etched with 0.5 M ethylenediaminetetraacetic acid (pH = 7.4) to stimulate hypersensitivity. The specimens were then randomly divided into 12 groups (n= 21) according to the surface treatments performed. After etching and bonding according to the manufacturer's recommendations in each group, the entire dentin surface was restored with Valux Plus composite resin. The samples were thermocycled and a universal test machine was used to measure the microtensile bond strength. The failure mode for each sample was observed under a stereomicroscope. For data analysis, the Bonferroni test, the independent t-test and the three-way anova test were used.</p><p><strong>Results: </strong>The average microtensile bond strength in non-laser samples was higher than the average in laser samples (<i>P</i><0.001). In comparison with the bonding agent type in both cases with and without laser, the highest average microtensile bond strength was related to ALL-BOND (<i>P</i><0.001), meanwhile the lowest average tensile strength in samples without laser was related to G-Premio universal adhesive (<i>P</i><0.001), and the lowest average microtensile strength in samples with laser belonged to Prime and Bond Elect group (<i>P</i><0.001).</p><p><strong>Conclusions: </strong>Nd: YAG laser irradiation of the dentin surface before applying the adhesive significantly decreased the microtensile bond strength of the composite resin to the dentin surface. <b>Key words:</b>Nd:YAG laser, Bond strength, Dentin, hypersensitivity, Universal adhesives.</p>\",\"PeriodicalId\":15376,\"journal\":{\"name\":\"Journal of Clinical and Experimental Dentistry\",\"volume\":\"16 6\",\"pages\":\"e685-e692\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310977/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical and Experimental Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4317/jced.61493\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.61493","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
摘要
背景:本研究旨在评估 Nd: YAG 激光对使用不同通用粘接系统的超敏牙本质复合树脂拉伸粘接强度的影响:切割 252 颗磨牙的牙冠后,去除厚度约为 2 mm 的颊颈部釉质,露出 252 个光滑的牙本质表面。然后用 0.5 M 乙二胺四乙酸(pH = 7.4)进行蚀刻,以刺激过敏反应。然后根据所进行的表面处理将试样随机分为 12 组(n= 21)。每组按照制造商的建议进行蚀刻和粘接后,用 Valux Plus 复合树脂修复整个牙本质表面。对样品进行热循环,并使用万能试验机测量微拉伸粘接强度。在体视显微镜下观察每个样品的失效模式。数据分析采用 Bonferroni 检验、独立 t 检验和三方 anova 检验:结果:非激光样品的平均微拉伸粘接强度高于激光样品(PPPPConclusions:在使用粘合剂之前用 Nd:YAG 激光照射牙本质表面会显著降低复合树脂与牙本质表面的微拉伸粘接强度。关键词:Nd:YAG 激光 粘接强度 牙本质过敏 通用粘合剂
Effect of the Nd:YAG laser on the micro-tensile bond strength of composite resin to dentin with hypersensitivity using different universal adhesives.
Background: This study aimed to evaluate the effect of the Nd: YAG laser on the tensile bond strength of composite resin to dentin with hypersensitivity using different universal bonding systems.
Material and methods: After cutting the crown of 252 molars, buccal cervical enamel was removed at a thickness of approximately 2 mm, and 252 smooth dentin surfaces were exposed. Then they were etched with 0.5 M ethylenediaminetetraacetic acid (pH = 7.4) to stimulate hypersensitivity. The specimens were then randomly divided into 12 groups (n= 21) according to the surface treatments performed. After etching and bonding according to the manufacturer's recommendations in each group, the entire dentin surface was restored with Valux Plus composite resin. The samples were thermocycled and a universal test machine was used to measure the microtensile bond strength. The failure mode for each sample was observed under a stereomicroscope. For data analysis, the Bonferroni test, the independent t-test and the three-way anova test were used.
Results: The average microtensile bond strength in non-laser samples was higher than the average in laser samples (P<0.001). In comparison with the bonding agent type in both cases with and without laser, the highest average microtensile bond strength was related to ALL-BOND (P<0.001), meanwhile the lowest average tensile strength in samples without laser was related to G-Premio universal adhesive (P<0.001), and the lowest average microtensile strength in samples with laser belonged to Prime and Bond Elect group (P<0.001).
Conclusions: Nd: YAG laser irradiation of the dentin surface before applying the adhesive significantly decreased the microtensile bond strength of the composite resin to the dentin surface. Key words:Nd:YAG laser, Bond strength, Dentin, hypersensitivity, Universal adhesives.
期刊介绍:
Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery