在青少年特发性脊柱侧凸治疗中植入低密度与高密度椎弓根螺钉的比较研究:随机临床试验

IF 0.7 Q4 CLINICAL NEUROLOGY Egyptian journal of neurosurgery Pub Date : 2024-08-05 DOI:10.1186/s41984-024-00308-2
Hosam Eldin Mostafa, Abdelrhman Saber Sayed Moustafa, Hazem Hassan El Zayat, Ahmed Koheil, Omar Abdel Aleem Ragab
{"title":"在青少年特发性脊柱侧凸治疗中植入低密度与高密度椎弓根螺钉的比较研究:随机临床试验","authors":"Hosam Eldin Mostafa, Abdelrhman Saber Sayed Moustafa, Hazem Hassan El Zayat, Ahmed Koheil, Omar Abdel Aleem Ragab","doi":"10.1186/s41984-024-00308-2","DOIUrl":null,"url":null,"abstract":"A number of studies have yielded disparate findings regarding the relationship between implant density and curve correction in adolescent idiopathic scoliosis (AIS) surgery. This study compared the efficacy and safety of low-density (LD) versus high-density (HD) pedicular screw implants in the correction of deformity in AIS regarding clinical, radiological, and quality of life outcomes. This study was a single-blind, parallel, randomized trial that enrolled 20 adolescent patients with idiopathic scoliosis scheduled for posterior spinal fusion surgery with all pedicle screw constructs. Patients were randomized into two groups of 10 patients each. The LD group included patients in whom the number of screws per fused spinal level had a density of 1.5 or less, while the HD group had a density greater than 1.5. The primary outcomes were the radiological findings of curve correction. The secondary outcomes included the correlation between implant density and curve correction, the amount of blood loss, operation time, number of screws, fusion level, hospital stay duration, and quality of life assessed by the Scoliosis Research Society 22r questionnaire. Radiologically, the postoperative main curves Cobb angles and their changes were comparable between both approaches without statistical correlation with the implant density (p˃0.05). The LD approach significantly shortened the operative time (p=0.015), number of screws (p=0.011), implant density (p<0.001), and hospital stay (p<0.001). However, quality of life scores before surgery and at final follow-up did not differ between the two techniques (p˃0.05). The use of a low-density approach is an effective and safe methodology for attaining satisfactory deformity correction in AIS patients. Furthermore, this approach confers the additional advantage of reduced operative time, number of screws, implant density, and hospital stay in comparison to the high-density approach. Trial registration Pan African Clinical Trial Registry, PACTR202404611444119. Registered 28 March 2024-Retrospectively registered, https://pactr.samrc.ac.za/TrialDisplay.aspx?TrialID=29382 ","PeriodicalId":72881,"journal":{"name":"Egyptian journal of neurosurgery","volume":"1 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative study of low-density versus high-density pedicular screw implantations in management of adolescent idiopathic scoliosis: a randomized clinical trial\",\"authors\":\"Hosam Eldin Mostafa, Abdelrhman Saber Sayed Moustafa, Hazem Hassan El Zayat, Ahmed Koheil, Omar Abdel Aleem Ragab\",\"doi\":\"10.1186/s41984-024-00308-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A number of studies have yielded disparate findings regarding the relationship between implant density and curve correction in adolescent idiopathic scoliosis (AIS) surgery. This study compared the efficacy and safety of low-density (LD) versus high-density (HD) pedicular screw implants in the correction of deformity in AIS regarding clinical, radiological, and quality of life outcomes. This study was a single-blind, parallel, randomized trial that enrolled 20 adolescent patients with idiopathic scoliosis scheduled for posterior spinal fusion surgery with all pedicle screw constructs. Patients were randomized into two groups of 10 patients each. The LD group included patients in whom the number of screws per fused spinal level had a density of 1.5 or less, while the HD group had a density greater than 1.5. The primary outcomes were the radiological findings of curve correction. The secondary outcomes included the correlation between implant density and curve correction, the amount of blood loss, operation time, number of screws, fusion level, hospital stay duration, and quality of life assessed by the Scoliosis Research Society 22r questionnaire. Radiologically, the postoperative main curves Cobb angles and their changes were comparable between both approaches without statistical correlation with the implant density (p˃0.05). The LD approach significantly shortened the operative time (p=0.015), number of screws (p=0.011), implant density (p<0.001), and hospital stay (p<0.001). However, quality of life scores before surgery and at final follow-up did not differ between the two techniques (p˃0.05). The use of a low-density approach is an effective and safe methodology for attaining satisfactory deformity correction in AIS patients. Furthermore, this approach confers the additional advantage of reduced operative time, number of screws, implant density, and hospital stay in comparison to the high-density approach. Trial registration Pan African Clinical Trial Registry, PACTR202404611444119. Registered 28 March 2024-Retrospectively registered, https://pactr.samrc.ac.za/TrialDisplay.aspx?TrialID=29382 \",\"PeriodicalId\":72881,\"journal\":{\"name\":\"Egyptian journal of neurosurgery\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Egyptian journal of neurosurgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s41984-024-00308-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian journal of neurosurgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41984-024-00308-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

关于青少年特发性脊柱侧凸(AIS)手术中植入物密度与曲线矫正之间的关系,许多研究都得出了不同的结论。本研究比较了低密度(LD)和高密度(HD)脊柱螺钉植入物在矫正青少年特发性脊柱侧凸畸形中的临床、放射学和生活质量方面的有效性和安全性。该研究是一项单盲、平行、随机试验,共招募了20名青少年特发性脊柱侧凸患者,他们计划使用所有椎弓根螺钉结构进行脊柱后路融合手术。患者被随机分为两组,每组 10 人。LD组包括每个融合脊柱水平的螺钉数量密度为1.5或以下的患者,而HD组的密度大于1.5。主要结果是曲线矫正的放射学结果。次要结果包括植入物密度与曲线矫正之间的相关性、失血量、手术时间、螺钉数量、融合水平、住院时间,以及脊柱侧弯研究协会 22r 问卷评估的生活质量。从影像学角度看,两种方法的术后主要曲线Cobb角及其变化情况相当,但与植入物密度无统计学相关性(p˃0.05)。LD方法明显缩短了手术时间(p=0.015)、螺钉数量(p=0.011)、植入物密度(p<0.001)和住院时间(p<0.001)。然而,手术前和最后随访时的生活质量评分在两种技术之间没有差异(p˃0.05)。使用低密度方法是一种有效且安全的方法,可使 AIS 患者获得满意的畸形矫正效果。此外,与高密度方法相比,这种方法还具有缩短手术时间、减少螺钉数量、降低植入物密度和缩短住院时间的优势。试验注册泛非临床试验注册中心,PACTR202404611444119。注册日期:2024 年 3 月 28 日-回顾注册,https://pactr.samrc.ac.za/TrialDisplay.aspx?TrialID=29382
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative study of low-density versus high-density pedicular screw implantations in management of adolescent idiopathic scoliosis: a randomized clinical trial
A number of studies have yielded disparate findings regarding the relationship between implant density and curve correction in adolescent idiopathic scoliosis (AIS) surgery. This study compared the efficacy and safety of low-density (LD) versus high-density (HD) pedicular screw implants in the correction of deformity in AIS regarding clinical, radiological, and quality of life outcomes. This study was a single-blind, parallel, randomized trial that enrolled 20 adolescent patients with idiopathic scoliosis scheduled for posterior spinal fusion surgery with all pedicle screw constructs. Patients were randomized into two groups of 10 patients each. The LD group included patients in whom the number of screws per fused spinal level had a density of 1.5 or less, while the HD group had a density greater than 1.5. The primary outcomes were the radiological findings of curve correction. The secondary outcomes included the correlation between implant density and curve correction, the amount of blood loss, operation time, number of screws, fusion level, hospital stay duration, and quality of life assessed by the Scoliosis Research Society 22r questionnaire. Radiologically, the postoperative main curves Cobb angles and their changes were comparable between both approaches without statistical correlation with the implant density (p˃0.05). The LD approach significantly shortened the operative time (p=0.015), number of screws (p=0.011), implant density (p<0.001), and hospital stay (p<0.001). However, quality of life scores before surgery and at final follow-up did not differ between the two techniques (p˃0.05). The use of a low-density approach is an effective and safe methodology for attaining satisfactory deformity correction in AIS patients. Furthermore, this approach confers the additional advantage of reduced operative time, number of screws, implant density, and hospital stay in comparison to the high-density approach. Trial registration Pan African Clinical Trial Registry, PACTR202404611444119. Registered 28 March 2024-Retrospectively registered, https://pactr.samrc.ac.za/TrialDisplay.aspx?TrialID=29382
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
32 weeks
期刊最新文献
Multidisciplinary team approach in management of anterior spinal dysraphism with unusual presentation: case series and surgical approach Analysis of moderate and severe traumatic brain injury associated with skull base fracture: a local tertiary center experience Conventional and old endovascular techniques for vertebral aneurysms still work in the era of flow diversion Possible effects of lumbar stabilization surgery on sagittal alignment, disability and quality of life Role of intraoperative cranial ultrasonography in detection of residual brain lesions during surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1