Tao Cheng , Noshin Afshan , Jianwei Jiao , Jin Jiao
{"title":"基于适配体的传感器在检测神经退行性疾病蛋白质生物标记物方面的最新进展","authors":"Tao Cheng , Noshin Afshan , Jianwei Jiao , Jin Jiao","doi":"10.1016/j.biosx.2024.100528","DOIUrl":null,"url":null,"abstract":"<div><p>Neurodegenerative diseases (NDs) have been a group of disorders characterized by neuronal death and functional loss including Alzheimer's disease (AD), Parkinson's disease (PD) and Huntington's disease (HD), etc. Since diagnostic methods for the NDs biomarkers have been based on traditional enzyme linked immunosorbent assay (ELISA) or Western Blotting, the antibody intrinsic drawbacks such as large molecular weight and high cost make early diagnosis of NDs quite challenging. The aptamers bridge this gap effectively and their versatile features such as small molecular weight, easy modification, high stability and low cost have been widely used to fabricate biosensors to diagnose NDs. Various aptamer-based biosensors have shown excellent performance in the early diagnosis of NDs. Several biomarkers including nucleic acid, protein, biomolecule, and exosome has been used as early diagnostic indicators for NDs. In this minireview, we aim to report the latest progress in aptasensors (including colorimetric, fluorescence, electrochemical and electrochemiluminescence, etc) for detecting NDs protein biomarkers, summarize principles of their functions along with challenges in the way to diagnose NDs and emphasize their future perspectives.</p></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"20 ","pages":"Article 100528"},"PeriodicalIF":10.6100,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S259013702400092X/pdfft?md5=c2ba70c354f3e5d24039205365f5bb40&pid=1-s2.0-S259013702400092X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Current progress in aptamer-based sensors for the detection of protein biomarkers in neurodegenerative diseases\",\"authors\":\"Tao Cheng , Noshin Afshan , Jianwei Jiao , Jin Jiao\",\"doi\":\"10.1016/j.biosx.2024.100528\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Neurodegenerative diseases (NDs) have been a group of disorders characterized by neuronal death and functional loss including Alzheimer's disease (AD), Parkinson's disease (PD) and Huntington's disease (HD), etc. Since diagnostic methods for the NDs biomarkers have been based on traditional enzyme linked immunosorbent assay (ELISA) or Western Blotting, the antibody intrinsic drawbacks such as large molecular weight and high cost make early diagnosis of NDs quite challenging. The aptamers bridge this gap effectively and their versatile features such as small molecular weight, easy modification, high stability and low cost have been widely used to fabricate biosensors to diagnose NDs. Various aptamer-based biosensors have shown excellent performance in the early diagnosis of NDs. Several biomarkers including nucleic acid, protein, biomolecule, and exosome has been used as early diagnostic indicators for NDs. In this minireview, we aim to report the latest progress in aptasensors (including colorimetric, fluorescence, electrochemical and electrochemiluminescence, etc) for detecting NDs protein biomarkers, summarize principles of their functions along with challenges in the way to diagnose NDs and emphasize their future perspectives.</p></div>\",\"PeriodicalId\":260,\"journal\":{\"name\":\"Biosensors and Bioelectronics: X\",\"volume\":\"20 \",\"pages\":\"Article 100528\"},\"PeriodicalIF\":10.6100,\"publicationDate\":\"2024-08-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S259013702400092X/pdfft?md5=c2ba70c354f3e5d24039205365f5bb40&pid=1-s2.0-S259013702400092X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors and Bioelectronics: X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S259013702400092X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S259013702400092X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
Current progress in aptamer-based sensors for the detection of protein biomarkers in neurodegenerative diseases
Neurodegenerative diseases (NDs) have been a group of disorders characterized by neuronal death and functional loss including Alzheimer's disease (AD), Parkinson's disease (PD) and Huntington's disease (HD), etc. Since diagnostic methods for the NDs biomarkers have been based on traditional enzyme linked immunosorbent assay (ELISA) or Western Blotting, the antibody intrinsic drawbacks such as large molecular weight and high cost make early diagnosis of NDs quite challenging. The aptamers bridge this gap effectively and their versatile features such as small molecular weight, easy modification, high stability and low cost have been widely used to fabricate biosensors to diagnose NDs. Various aptamer-based biosensors have shown excellent performance in the early diagnosis of NDs. Several biomarkers including nucleic acid, protein, biomolecule, and exosome has been used as early diagnostic indicators for NDs. In this minireview, we aim to report the latest progress in aptasensors (including colorimetric, fluorescence, electrochemical and electrochemiluminescence, etc) for detecting NDs protein biomarkers, summarize principles of their functions along with challenges in the way to diagnose NDs and emphasize their future perspectives.
期刊介绍:
Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.