在 LArIAT 实验中测量氩上静止时的负离子和介子核俘获

M. A. Hernandez-Morquecho, R. Acciarri, J. Asaadi, M. Backfish, W. Badgett, V. Basque, F. d. M. Blaszczyk, W. Foreman, R. Gomes, E. Gramellini, J. Ho, E. Kearns, E. Kemp, T. Kobilarcik, M. King, B. R. Littlejohn, X. Luo, A. Marchionni, C. A. Moura, J. L. Raaf, D. W. Schmitz, M. Soderberg, J. M. St. John, A. M. Szelc, T. Yang
{"title":"在 LArIAT 实验中测量氩上静止时的负离子和介子核俘获","authors":"M. A. Hernandez-Morquecho, R. Acciarri, J. Asaadi, M. Backfish, W. Badgett, V. Basque, F. d. M. Blaszczyk, W. Foreman, R. Gomes, E. Gramellini, J. Ho, E. Kearns, E. Kemp, T. Kobilarcik, M. King, B. R. Littlejohn, X. Luo, A. Marchionni, C. A. Moura, J. L. Raaf, D. W. Schmitz, M. Soderberg, J. M. St. John, A. M. Szelc, T. Yang","doi":"arxiv-2408.05133","DOIUrl":null,"url":null,"abstract":"We report the measurement of the final-state products of negative pion and\nmuon nuclear capture at rest on argon by the LArIAT experiment at the Fermilab\nTest Beam Facility. We measure a population of isolated MeV-scale energy\ndepositions, or blips, in 296 LArIAT events containing tracks from stopping\nlow-momentum pions and muons. The average numbers of visible blips are measured\nto be 0.74 $\\pm$ 0.19 and 1.86 $\\pm$ 0.17 near muon and pion track endpoints,\nrespectively. The 3.6$\\sigma$ statistically significant difference in blip\ncontent between muons and pions provides the first demonstration of a new\nmethod of pion-muon discrimination in neutrino liquid argon time projection\nchamber experiments. LArIAT Monte Carlo simulations predict substantially\nhigher average blip counts for negative muon (1.22 $\\pm$ 0.08) and pion (2.34\n$\\pm$ 0.09) nuclear captures. We attribute this difference to Geant4's\ninaccurate simulation of the nuclear capture process.","PeriodicalId":501374,"journal":{"name":"arXiv - PHYS - Instrumentation and Detectors","volume":"37 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Experiment\",\"authors\":\"M. A. Hernandez-Morquecho, R. Acciarri, J. Asaadi, M. Backfish, W. Badgett, V. Basque, F. d. M. Blaszczyk, W. Foreman, R. Gomes, E. Gramellini, J. Ho, E. Kearns, E. Kemp, T. Kobilarcik, M. King, B. R. Littlejohn, X. Luo, A. Marchionni, C. A. Moura, J. L. Raaf, D. W. Schmitz, M. Soderberg, J. M. St. John, A. M. Szelc, T. Yang\",\"doi\":\"arxiv-2408.05133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report the measurement of the final-state products of negative pion and\\nmuon nuclear capture at rest on argon by the LArIAT experiment at the Fermilab\\nTest Beam Facility. We measure a population of isolated MeV-scale energy\\ndepositions, or blips, in 296 LArIAT events containing tracks from stopping\\nlow-momentum pions and muons. The average numbers of visible blips are measured\\nto be 0.74 $\\\\pm$ 0.19 and 1.86 $\\\\pm$ 0.17 near muon and pion track endpoints,\\nrespectively. The 3.6$\\\\sigma$ statistically significant difference in blip\\ncontent between muons and pions provides the first demonstration of a new\\nmethod of pion-muon discrimination in neutrino liquid argon time projection\\nchamber experiments. LArIAT Monte Carlo simulations predict substantially\\nhigher average blip counts for negative muon (1.22 $\\\\pm$ 0.08) and pion (2.34\\n$\\\\pm$ 0.09) nuclear captures. We attribute this difference to Geant4's\\ninaccurate simulation of the nuclear capture process.\",\"PeriodicalId\":501374,\"journal\":{\"name\":\"arXiv - PHYS - Instrumentation and Detectors\",\"volume\":\"37 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv - PHYS - Instrumentation and Detectors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/arxiv-2408.05133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Instrumentation and Detectors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2408.05133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们报告了费米实验室试验光束设施的 LArIAT 实验对负先驱和μ介子在氩上静止时核俘获的终态产物的测量结果。我们测量了296个LArIAT事件中孤立的MeV尺度能量沉积(或称 "猝灭"),这些事件包含来自停止低动量离子和μ介子的轨道。在μ介子和先驱轨道端点附近测得的可见闪点的平均数量分别为0.74和1.86。μ介子和pion之间的闪烁含量在统计上的显著差异为中微子液氩时间投影室实验中先驱-μ介子分辨的新方法提供了首次证明。LArIAT蒙特卡洛模拟预测负μ介子(1.22$\pm$ 0.08)和先锋(2.34$\pm$ 0.09)核俘获的平均闪烁计数要高得多。我们把这种差异归因于 Geant4 对核俘获过程的精确模拟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurements of Pion and Muon Nuclear Capture at Rest on Argon in the LArIAT Experiment
We report the measurement of the final-state products of negative pion and muon nuclear capture at rest on argon by the LArIAT experiment at the Fermilab Test Beam Facility. We measure a population of isolated MeV-scale energy depositions, or blips, in 296 LArIAT events containing tracks from stopping low-momentum pions and muons. The average numbers of visible blips are measured to be 0.74 $\pm$ 0.19 and 1.86 $\pm$ 0.17 near muon and pion track endpoints, respectively. The 3.6$\sigma$ statistically significant difference in blip content between muons and pions provides the first demonstration of a new method of pion-muon discrimination in neutrino liquid argon time projection chamber experiments. LArIAT Monte Carlo simulations predict substantially higher average blip counts for negative muon (1.22 $\pm$ 0.08) and pion (2.34 $\pm$ 0.09) nuclear captures. We attribute this difference to Geant4's inaccurate simulation of the nuclear capture process.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Impedance Matching Networks for Scanning Microwave Microscopy Ultraviolet cross-luminescence in ternary chlorides of alkali and alkaline-earth metals Performance Evaluation of an RFSoC Operating in a 1.25 Tesla Magnetic Field Numerical Studies of Straw Tube Detectors Advanced Halide Scintillators: From the Bulk to Nano
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1