Shuailin Zheng , Jianmin Zhou , Fei Ma , Changwen Du
{"title":"利用傅立叶变换中红外衰减全反射光谱传感天然水体总磷的自适应模型","authors":"Shuailin Zheng , Jianmin Zhou , Fei Ma , Changwen Du","doi":"10.1016/j.snr.2024.100230","DOIUrl":null,"url":null,"abstract":"<div><p>As the most economically developed area in China, the environmental water quality of Guangdong-Hong Kong-Macao Greater Bay Area has received extensive attention, and the spatial variations of total phosphorus (TP) in the Greater Bay were significant, conventional laboratory analysis is difficult to meet the requirements of TP monitoring due to time and cost consuming, and Fourier transform infrared attenuated total reflectance spectroscopy (FTIR-ATR) technology, combined with the self-adaptive partial least squares (SA-PLS) model, was used to determine the TP concentration. The results showed that P-O vibrations were observed in the wavenumber range of 1200–900 cm<sup>−1</sup>, and prediction models were established by using this range. For the conventional partial least squares (PLS) model, the <em>R</em><sup>2</sup>, <em>RMSE</em> and <em>RPD</em> were 0.817, 0.022 mg L<sup>−1</sup> and 2.335, respectively, while for the SA-PLS model the prediction was improved with the values of 0.965, 0.010 mg L<sup>−1</sup>, 5.296, respectively, and the SA-PLS mode prediction was satisfied when the TP content in water was more than 0.05 mg L<sup>−1</sup>. It was found that the TP determination was interfered by sulfate, when the sulfate content was < 100 mg L<sup>−1</sup>, both SA-PLS and the conventional PLS model could be used for quantitative analysis of TP; when sulfate content was > 100 mg L<sup>−1</sup>, PLS model could not be used while the SA-PLS model still achieved an excellent prediction. Therefore, FTIR-ATR combined with SA-PLS model can rapidly determine TP in water, providing an alternative strategy for monitoring TP in natural water bodies.</p></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"8 ","pages":"Article 100230"},"PeriodicalIF":6.5000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666053924000468/pdfft?md5=8f4d5a932a4619b1c7cc37945f0d8300&pid=1-s2.0-S2666053924000468-main.pdf","citationCount":"0","resultStr":"{\"title\":\"A self-adaptive model for sensing total phosphorus in natural water bodies using Fourier transform mid-infrared attenuated total reflectance spectroscopy\",\"authors\":\"Shuailin Zheng , Jianmin Zhou , Fei Ma , Changwen Du\",\"doi\":\"10.1016/j.snr.2024.100230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>As the most economically developed area in China, the environmental water quality of Guangdong-Hong Kong-Macao Greater Bay Area has received extensive attention, and the spatial variations of total phosphorus (TP) in the Greater Bay were significant, conventional laboratory analysis is difficult to meet the requirements of TP monitoring due to time and cost consuming, and Fourier transform infrared attenuated total reflectance spectroscopy (FTIR-ATR) technology, combined with the self-adaptive partial least squares (SA-PLS) model, was used to determine the TP concentration. The results showed that P-O vibrations were observed in the wavenumber range of 1200–900 cm<sup>−1</sup>, and prediction models were established by using this range. For the conventional partial least squares (PLS) model, the <em>R</em><sup>2</sup>, <em>RMSE</em> and <em>RPD</em> were 0.817, 0.022 mg L<sup>−1</sup> and 2.335, respectively, while for the SA-PLS model the prediction was improved with the values of 0.965, 0.010 mg L<sup>−1</sup>, 5.296, respectively, and the SA-PLS mode prediction was satisfied when the TP content in water was more than 0.05 mg L<sup>−1</sup>. It was found that the TP determination was interfered by sulfate, when the sulfate content was < 100 mg L<sup>−1</sup>, both SA-PLS and the conventional PLS model could be used for quantitative analysis of TP; when sulfate content was > 100 mg L<sup>−1</sup>, PLS model could not be used while the SA-PLS model still achieved an excellent prediction. Therefore, FTIR-ATR combined with SA-PLS model can rapidly determine TP in water, providing an alternative strategy for monitoring TP in natural water bodies.</p></div>\",\"PeriodicalId\":426,\"journal\":{\"name\":\"Sensors and Actuators Reports\",\"volume\":\"8 \",\"pages\":\"Article 100230\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2024-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666053924000468/pdfft?md5=8f4d5a932a4619b1c7cc37945f0d8300&pid=1-s2.0-S2666053924000468-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666053924000468\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053924000468","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
作为中国经济最发达的地区,粤港澳大湾区的环境水质受到广泛关注,大湾区总磷(TP)空间变化显著,常规实验室分析耗时耗钱,难以满足TP监测的要求,采用傅立叶变换红外衰减全反射光谱(FTIR-ATR)技术,结合自适应偏最小二乘法(SA-PLS)模型,测定TP浓度。结果表明,在 1200-900 厘米的波长范围内观察到了 P-O 振动,并利用这一范围建立了预测模型。对于传统的偏最小二乘法(PLS)模型,Ⅳ和Ⅴ值分别为 0.817、0.022 mg L 和 2.335,而对于 SA-PLS 模型,预测值有所提高,分别为 0.965、0.010 mg L 和 5.296,当水中的 TP 含量大于 0.05 mg L 时,SA-PLS 模式的预测结果符合要求。研究发现,TP 的测定受到硫酸盐的干扰,当硫酸盐含量小于 100 mg L 时,SA-PLS 和传统的 PLS 模式均可用于 TP 的定量分析;当硫酸盐含量大于 100 mg L 时,PLS 模式无法使用,而 SA-PLS 模式仍能达到很好的预测效果。因此,傅立叶变换红外-ATR结合SA-PLS模型可快速测定水中的TP,为监测天然水体中的TP提供了另一种策略。
A self-adaptive model for sensing total phosphorus in natural water bodies using Fourier transform mid-infrared attenuated total reflectance spectroscopy
As the most economically developed area in China, the environmental water quality of Guangdong-Hong Kong-Macao Greater Bay Area has received extensive attention, and the spatial variations of total phosphorus (TP) in the Greater Bay were significant, conventional laboratory analysis is difficult to meet the requirements of TP monitoring due to time and cost consuming, and Fourier transform infrared attenuated total reflectance spectroscopy (FTIR-ATR) technology, combined with the self-adaptive partial least squares (SA-PLS) model, was used to determine the TP concentration. The results showed that P-O vibrations were observed in the wavenumber range of 1200–900 cm−1, and prediction models were established by using this range. For the conventional partial least squares (PLS) model, the R2, RMSE and RPD were 0.817, 0.022 mg L−1 and 2.335, respectively, while for the SA-PLS model the prediction was improved with the values of 0.965, 0.010 mg L−1, 5.296, respectively, and the SA-PLS mode prediction was satisfied when the TP content in water was more than 0.05 mg L−1. It was found that the TP determination was interfered by sulfate, when the sulfate content was < 100 mg L−1, both SA-PLS and the conventional PLS model could be used for quantitative analysis of TP; when sulfate content was > 100 mg L−1, PLS model could not be used while the SA-PLS model still achieved an excellent prediction. Therefore, FTIR-ATR combined with SA-PLS model can rapidly determine TP in water, providing an alternative strategy for monitoring TP in natural water bodies.
期刊介绍:
Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications.
For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.