遮阳程度对太阳能光伏组串的电压、电流和功率的影响

{"title":"遮阳程度对太阳能光伏组串的电压、电流和功率的影响","authors":"","doi":"10.1016/j.nxsust.2024.100062","DOIUrl":null,"url":null,"abstract":"<div><p>The short-term power output variability of solar photovoltaic (PV) systems caused by passing clouds is becoming a major concern for grid operators. As the penetration of utility-scale PV systems boosts, the rapid power fluctuations greatly challenge the grid's transient stability. A photo voltaic system is greatly vulnerable to Partial Shading. The performance analysis of PV systems clearly suggests that the maximum power of partially shaded PV systems is inversely proportional to the heaviness of shading. However, some literatures are not of the same opinion; for them, the maximum power of a partially shaded system is invulnerable to shading heaviness, often at certain critical points. According to research on the P-V characteristic curve under various numbers of shaded modules and shading levels, the irradiance of the shaded modules reaches a certain turning point or critical point. The PV array becomes insensitive to high-level shading, categorically for the series topology. This paper presents an experimental results of performance parameters with varying shading heaviness. The experiment is performed on a Photovoltaics string of series connected modules, a 119KW grid-connected rooftop solar power plant using the Power Quality analyser for continuous recording of various parameters under changing shading heaviness. The degree or heaviness of shading decides the critical point. The critical point can vary based on the number of the shaded modules.</p></div>","PeriodicalId":100960,"journal":{"name":"Next Sustainability","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2949823624000394/pdfft?md5=95119dd297c9d89bbb9ce28827a458eb&pid=1-s2.0-S2949823624000394-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Impact of shading heaviness on voltage, current and power of the solar photovoltaic string\",\"authors\":\"\",\"doi\":\"10.1016/j.nxsust.2024.100062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The short-term power output variability of solar photovoltaic (PV) systems caused by passing clouds is becoming a major concern for grid operators. As the penetration of utility-scale PV systems boosts, the rapid power fluctuations greatly challenge the grid's transient stability. A photo voltaic system is greatly vulnerable to Partial Shading. The performance analysis of PV systems clearly suggests that the maximum power of partially shaded PV systems is inversely proportional to the heaviness of shading. However, some literatures are not of the same opinion; for them, the maximum power of a partially shaded system is invulnerable to shading heaviness, often at certain critical points. According to research on the P-V characteristic curve under various numbers of shaded modules and shading levels, the irradiance of the shaded modules reaches a certain turning point or critical point. The PV array becomes insensitive to high-level shading, categorically for the series topology. This paper presents an experimental results of performance parameters with varying shading heaviness. The experiment is performed on a Photovoltaics string of series connected modules, a 119KW grid-connected rooftop solar power plant using the Power Quality analyser for continuous recording of various parameters under changing shading heaviness. The degree or heaviness of shading decides the critical point. The critical point can vary based on the number of the shaded modules.</p></div>\",\"PeriodicalId\":100960,\"journal\":{\"name\":\"Next Sustainability\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2949823624000394/pdfft?md5=95119dd297c9d89bbb9ce28827a458eb&pid=1-s2.0-S2949823624000394-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Next Sustainability\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2949823624000394\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Next Sustainability","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949823624000394","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

云层经过时引起的太阳能光伏 (PV) 系统的短期功率输出变化正成为电网运营商关注的主要问题。随着公用事业级光伏系统的普及,快速的功率波动对电网的瞬态稳定性提出了极大挑战。光电系统极易受到部分遮挡的影响。光伏系统的性能分析表明,部分遮挡光伏系统的最大功率与遮挡程度成反比。然而,有些文献并不这样认为,他们认为部分遮阳系统的最大功率不受遮阳程度的影响,通常是在某些临界点。根据对不同遮阳组件数量和遮阳水平下 P-V 特性曲线的研究,遮阳组件的辐照度会达到某个转折点或临界点。对于串联拓扑结构而言,光伏阵列对高水平遮光变得不敏感。本文介绍了不同遮阳程度下性能参数的实验结果。实验是在一个由串联模块组成的光伏串上进行的,这是一个 119 千瓦的并网屋顶太阳能发电站,使用电能质量分析仪连续记录遮阳程度变化时的各种参数。遮光的程度或严重程度决定了临界点。临界点可根据遮光模块的数量而变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of shading heaviness on voltage, current and power of the solar photovoltaic string

The short-term power output variability of solar photovoltaic (PV) systems caused by passing clouds is becoming a major concern for grid operators. As the penetration of utility-scale PV systems boosts, the rapid power fluctuations greatly challenge the grid's transient stability. A photo voltaic system is greatly vulnerable to Partial Shading. The performance analysis of PV systems clearly suggests that the maximum power of partially shaded PV systems is inversely proportional to the heaviness of shading. However, some literatures are not of the same opinion; for them, the maximum power of a partially shaded system is invulnerable to shading heaviness, often at certain critical points. According to research on the P-V characteristic curve under various numbers of shaded modules and shading levels, the irradiance of the shaded modules reaches a certain turning point or critical point. The PV array becomes insensitive to high-level shading, categorically for the series topology. This paper presents an experimental results of performance parameters with varying shading heaviness. The experiment is performed on a Photovoltaics string of series connected modules, a 119KW grid-connected rooftop solar power plant using the Power Quality analyser for continuous recording of various parameters under changing shading heaviness. The degree or heaviness of shading decides the critical point. The critical point can vary based on the number of the shaded modules.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Review of starch-based coagulants for water treatment: Mechanisms, extraction and surface modification Use of EDS/EDX to evaluate heavy metals pollution in water sources Incorporating industrial residue of submerged arc welding (SAW) in cement-based mortar matrices as a green strategy Copper-catalyzed plastic waste synthesized graphene nanosheets/polypyrrole nanocomposites for efficient thermoelectric applications BIM-based parametric energy analysis of green building components for the roofs and facades
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1