{"title":"基于节点度量指数的 DPMU 多级优化布局","authors":"","doi":"10.1016/j.segan.2024.101488","DOIUrl":null,"url":null,"abstract":"<div><p>The proliferation of distributed energy resources and the introduction of new loads in distribution networks present significant challenges for monitoring and operation. To satisfy the enhanced observability and controllability requirements of modern distribution networks, there is an increasing demand for advanced monitoring devices. Distribution Network Phasor Measurement Units (DPMUs) offer high-precision measurement data with precise timestamps, thereby improving both the accuracy and redundancy of measurements within the distribution network.This paper introduces an optimization model for the strategic placement of PMUs within distribution networks, leveraging node metric indices. The indices considered are node degree, spatiotemporal correlation, and node power ratio. The relative importance of these indices is determined using an improved entropy weight method, which quantifies the differentiation of nodes within the network. This method facilitates the prioritized placement of DPMUs at critical nodes. The proposed model also incorporates constraints such as the depth of unobservability and zero injection nodes. Utilizing a 0–1 integer programming algorithm, the model derives a multi-stage optimal placement scheme for PMU placement. This scheme evolves from incomplete observability to critical observability and ultimately to full redundancy. Importantly, this approach allows for the monitoring of key nodes within the distribution network and enhances measurement redundancy without necessitating an increase in the number of placements.</p></div>","PeriodicalId":56142,"journal":{"name":"Sustainable Energy Grids & Networks","volume":null,"pages":null},"PeriodicalIF":4.8000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-stage optimization placement of DPMUs based on node metric indices\",\"authors\":\"\",\"doi\":\"10.1016/j.segan.2024.101488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The proliferation of distributed energy resources and the introduction of new loads in distribution networks present significant challenges for monitoring and operation. To satisfy the enhanced observability and controllability requirements of modern distribution networks, there is an increasing demand for advanced monitoring devices. Distribution Network Phasor Measurement Units (DPMUs) offer high-precision measurement data with precise timestamps, thereby improving both the accuracy and redundancy of measurements within the distribution network.This paper introduces an optimization model for the strategic placement of PMUs within distribution networks, leveraging node metric indices. The indices considered are node degree, spatiotemporal correlation, and node power ratio. The relative importance of these indices is determined using an improved entropy weight method, which quantifies the differentiation of nodes within the network. This method facilitates the prioritized placement of DPMUs at critical nodes. The proposed model also incorporates constraints such as the depth of unobservability and zero injection nodes. Utilizing a 0–1 integer programming algorithm, the model derives a multi-stage optimal placement scheme for PMU placement. This scheme evolves from incomplete observability to critical observability and ultimately to full redundancy. Importantly, this approach allows for the monitoring of key nodes within the distribution network and enhances measurement redundancy without necessitating an increase in the number of placements.</p></div>\",\"PeriodicalId\":56142,\"journal\":{\"name\":\"Sustainable Energy Grids & Networks\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sustainable Energy Grids & Networks\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352467724002170\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sustainable Energy Grids & Networks","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352467724002170","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Multi-stage optimization placement of DPMUs based on node metric indices
The proliferation of distributed energy resources and the introduction of new loads in distribution networks present significant challenges for monitoring and operation. To satisfy the enhanced observability and controllability requirements of modern distribution networks, there is an increasing demand for advanced monitoring devices. Distribution Network Phasor Measurement Units (DPMUs) offer high-precision measurement data with precise timestamps, thereby improving both the accuracy and redundancy of measurements within the distribution network.This paper introduces an optimization model for the strategic placement of PMUs within distribution networks, leveraging node metric indices. The indices considered are node degree, spatiotemporal correlation, and node power ratio. The relative importance of these indices is determined using an improved entropy weight method, which quantifies the differentiation of nodes within the network. This method facilitates the prioritized placement of DPMUs at critical nodes. The proposed model also incorporates constraints such as the depth of unobservability and zero injection nodes. Utilizing a 0–1 integer programming algorithm, the model derives a multi-stage optimal placement scheme for PMU placement. This scheme evolves from incomplete observability to critical observability and ultimately to full redundancy. Importantly, this approach allows for the monitoring of key nodes within the distribution network and enhances measurement redundancy without necessitating an increase in the number of placements.
期刊介绍:
Sustainable Energy, Grids and Networks (SEGAN)is an international peer-reviewed publication for theoretical and applied research dealing with energy, information grids and power networks, including smart grids from super to micro grid scales. SEGAN welcomes papers describing fundamental advances in mathematical, statistical or computational methods with application to power and energy systems, as well as papers on applications, computation and modeling in the areas of electrical and energy systems with coupled information and communication technologies.