基于节点度量指数的 DPMU 多级优化布局

IF 4.8 2区 工程技术 Q2 ENERGY & FUELS Sustainable Energy Grids & Networks Pub Date : 2024-07-30 DOI:10.1016/j.segan.2024.101488
{"title":"基于节点度量指数的 DPMU 多级优化布局","authors":"","doi":"10.1016/j.segan.2024.101488","DOIUrl":null,"url":null,"abstract":"<div><p>The proliferation of distributed energy resources and the introduction of new loads in distribution networks present significant challenges for monitoring and operation. To satisfy the enhanced observability and controllability requirements of modern distribution networks, there is an increasing demand for advanced monitoring devices. Distribution Network Phasor Measurement Units (DPMUs) offer high-precision measurement data with precise timestamps, thereby improving both the accuracy and redundancy of measurements within the distribution network.This paper introduces an optimization model for the strategic placement of PMUs within distribution networks, leveraging node metric indices. The indices considered are node degree, spatiotemporal correlation, and node power ratio. The relative importance of these indices is determined using an improved entropy weight method, which quantifies the differentiation of nodes within the network. This method facilitates the prioritized placement of DPMUs at critical nodes. The proposed model also incorporates constraints such as the depth of unobservability and zero injection nodes. Utilizing a 0–1 integer programming algorithm, the model derives a multi-stage optimal placement scheme for PMU placement. This scheme evolves from incomplete observability to critical observability and ultimately to full redundancy. Importantly, this approach allows for the monitoring of key nodes within the distribution network and enhances measurement redundancy without necessitating an increase in the number of placements.</p></div>","PeriodicalId":56142,"journal":{"name":"Sustainable Energy Grids & Networks","volume":null,"pages":null},"PeriodicalIF":4.8000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-stage optimization placement of DPMUs based on node metric indices\",\"authors\":\"\",\"doi\":\"10.1016/j.segan.2024.101488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The proliferation of distributed energy resources and the introduction of new loads in distribution networks present significant challenges for monitoring and operation. To satisfy the enhanced observability and controllability requirements of modern distribution networks, there is an increasing demand for advanced monitoring devices. Distribution Network Phasor Measurement Units (DPMUs) offer high-precision measurement data with precise timestamps, thereby improving both the accuracy and redundancy of measurements within the distribution network.This paper introduces an optimization model for the strategic placement of PMUs within distribution networks, leveraging node metric indices. The indices considered are node degree, spatiotemporal correlation, and node power ratio. The relative importance of these indices is determined using an improved entropy weight method, which quantifies the differentiation of nodes within the network. This method facilitates the prioritized placement of DPMUs at critical nodes. The proposed model also incorporates constraints such as the depth of unobservability and zero injection nodes. Utilizing a 0–1 integer programming algorithm, the model derives a multi-stage optimal placement scheme for PMU placement. This scheme evolves from incomplete observability to critical observability and ultimately to full redundancy. Importantly, this approach allows for the monitoring of key nodes within the distribution network and enhances measurement redundancy without necessitating an increase in the number of placements.</p></div>\",\"PeriodicalId\":56142,\"journal\":{\"name\":\"Sustainable Energy Grids & Networks\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sustainable Energy Grids & Networks\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352467724002170\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sustainable Energy Grids & Networks","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352467724002170","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

分布式能源资源的激增以及配电网络中新负载的引入,给监控和运行带来了巨大挑战。为满足现代配电网对可观测性和可控性的更高要求,对先进监控设备的需求日益增长。配电网相量测量单元(DPMU)可提供具有精确时间戳的高精度测量数据,从而提高配电网内测量的准确性和冗余性。考虑的指标包括节点度、时空相关性和节点功率比。这些指标的相对重要性是通过改进的熵权法确定的,该方法可量化网络内节点的差异。这种方法有助于在关键节点优先放置 DPMU。所提出的模型还纳入了不可观测深度和零注入节点等约束条件。利用 0-1 整数编程算法,该模型得出了 PMU 布置的多阶段优化布置方案。该方案从不完全可观测性发展到临界可观测性,最终达到完全冗余。重要的是,这种方法允许对配电网络中的关键节点进行监控,并在无需增加安置数量的情况下增强了测量冗余度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Multi-stage optimization placement of DPMUs based on node metric indices

The proliferation of distributed energy resources and the introduction of new loads in distribution networks present significant challenges for monitoring and operation. To satisfy the enhanced observability and controllability requirements of modern distribution networks, there is an increasing demand for advanced monitoring devices. Distribution Network Phasor Measurement Units (DPMUs) offer high-precision measurement data with precise timestamps, thereby improving both the accuracy and redundancy of measurements within the distribution network.This paper introduces an optimization model for the strategic placement of PMUs within distribution networks, leveraging node metric indices. The indices considered are node degree, spatiotemporal correlation, and node power ratio. The relative importance of these indices is determined using an improved entropy weight method, which quantifies the differentiation of nodes within the network. This method facilitates the prioritized placement of DPMUs at critical nodes. The proposed model also incorporates constraints such as the depth of unobservability and zero injection nodes. Utilizing a 0–1 integer programming algorithm, the model derives a multi-stage optimal placement scheme for PMU placement. This scheme evolves from incomplete observability to critical observability and ultimately to full redundancy. Importantly, this approach allows for the monitoring of key nodes within the distribution network and enhances measurement redundancy without necessitating an increase in the number of placements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sustainable Energy Grids & Networks
Sustainable Energy Grids & Networks Energy-Energy Engineering and Power Technology
CiteScore
7.90
自引率
13.00%
发文量
206
审稿时长
49 days
期刊介绍: Sustainable Energy, Grids and Networks (SEGAN)is an international peer-reviewed publication for theoretical and applied research dealing with energy, information grids and power networks, including smart grids from super to micro grid scales. SEGAN welcomes papers describing fundamental advances in mathematical, statistical or computational methods with application to power and energy systems, as well as papers on applications, computation and modeling in the areas of electrical and energy systems with coupled information and communication technologies.
期刊最新文献
Secured energy data transaction for prosumers under diverse cyberattack scenarios Investigating the long-term benefits of EU electricity highways: The case of the Green Aegean Interconnector Blockchain-enabled transformation: Decentralized planning and secure peer-to-peer trading in local energy networks Integrated real-time dispatch of power and gas systems Two-stage low-carbon economic dispatch of an integrated energy system considering flexible decoupling of electricity and heat on sides of source and load
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1