基于区间模型和实验验证的用于电缆减振的负刚度阻尼器鲁棒性评估

IF 4.6 2区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY Structural Control & Health Monitoring Pub Date : 2024-07-24 DOI:10.1155/2024/1258183
Xiang Shi, Xiaolin Wei, Jin-Yang Li, Heming Xing, Qinlin Cai
{"title":"基于区间模型和实验验证的用于电缆减振的负刚度阻尼器鲁棒性评估","authors":"Xiang Shi,&nbsp;Xiaolin Wei,&nbsp;Jin-Yang Li,&nbsp;Heming Xing,&nbsp;Qinlin Cai","doi":"10.1155/2024/1258183","DOIUrl":null,"url":null,"abstract":"<div>\n <p>The negative stiffness damper (NSD) has emerged as a promising passive vibration control device for cable structures due to its simplicity and effectiveness. However, uncertainties stemming from both internal and external environmental factors can potentially compromise the NSD’s performance in real-world applications, posing risks to cable safety. In response, this paper conducts a robustness evaluation on an integrated cable-NSD system, taking into account various potential uncertainties. Specifically, the uncertain parameters are described by interval variables. Consequently, an interval model is constructed to delineate the boundaries of cable dynamic responses when subjected to these uncertainties. The model’s accuracy is validated against experimental results. Subsequent simulations involve assessing interval responses for both single- and multimode cable vibrations under varying uncertainties. Finally, the NSD’s robustness concerning cable vibration control is evaluated using the model, which incorporates the first-passage theory. This analysis delves into the relationships among confidence levels, performance measures, and the variation range of uncertainties. The results indicate that for single-mode vibration control, there is a 90% confidence level that the damping ratio reduction remains within 10%. As for multimode vibration control, a 90% confidence level is established that the amplification falls within 17%.</p>\n </div>","PeriodicalId":49471,"journal":{"name":"Structural Control & Health Monitoring","volume":"2024 1","pages":""},"PeriodicalIF":4.6000,"publicationDate":"2024-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/1258183","citationCount":"0","resultStr":"{\"title\":\"Robustness Evaluation of Negative Stiffness Damper for Cable Vibration Mitigation Based on Interval Model with Experimental Validation\",\"authors\":\"Xiang Shi,&nbsp;Xiaolin Wei,&nbsp;Jin-Yang Li,&nbsp;Heming Xing,&nbsp;Qinlin Cai\",\"doi\":\"10.1155/2024/1258183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n <p>The negative stiffness damper (NSD) has emerged as a promising passive vibration control device for cable structures due to its simplicity and effectiveness. However, uncertainties stemming from both internal and external environmental factors can potentially compromise the NSD’s performance in real-world applications, posing risks to cable safety. In response, this paper conducts a robustness evaluation on an integrated cable-NSD system, taking into account various potential uncertainties. Specifically, the uncertain parameters are described by interval variables. Consequently, an interval model is constructed to delineate the boundaries of cable dynamic responses when subjected to these uncertainties. The model’s accuracy is validated against experimental results. Subsequent simulations involve assessing interval responses for both single- and multimode cable vibrations under varying uncertainties. Finally, the NSD’s robustness concerning cable vibration control is evaluated using the model, which incorporates the first-passage theory. This analysis delves into the relationships among confidence levels, performance measures, and the variation range of uncertainties. The results indicate that for single-mode vibration control, there is a 90% confidence level that the damping ratio reduction remains within 10%. As for multimode vibration control, a 90% confidence level is established that the amplification falls within 17%.</p>\\n </div>\",\"PeriodicalId\":49471,\"journal\":{\"name\":\"Structural Control & Health Monitoring\",\"volume\":\"2024 1\",\"pages\":\"\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-07-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/1258183\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Control & Health Monitoring\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1155/2024/1258183\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Control & Health Monitoring","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2024/1258183","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

负刚度阻尼器(NSD)因其简单有效,已成为一种很有前途的电缆结构被动振动控制装置。然而,由内部和外部环境因素引起的不确定性可能会影响 NSD 在实际应用中的性能,从而给电缆安全带来风险。为此,本文考虑到各种潜在的不确定性,对集成电缆-NSD 系统进行了鲁棒性评估。具体来说,不确定参数由区间变量描述。因此,本文构建了一个区间模型,以划定电缆在受到这些不确定性影响时的动态响应边界。该模型的准确性根据实验结果进行了验证。随后的模拟包括评估不同不确定性下单模和多模电缆振动的区间响应。最后,使用包含第一通道理论的模型对 NSD 在电缆振动控制方面的稳健性进行评估。该分析深入探讨了置信度、性能指标和不确定性变化范围之间的关系。结果表明,对于单模振动控制,有 90% 的置信度可以确保阻尼比的减小保持在 10% 以内。至于多模式振动控制,90% 的置信度为放大率在 17% 以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robustness Evaluation of Negative Stiffness Damper for Cable Vibration Mitigation Based on Interval Model with Experimental Validation

The negative stiffness damper (NSD) has emerged as a promising passive vibration control device for cable structures due to its simplicity and effectiveness. However, uncertainties stemming from both internal and external environmental factors can potentially compromise the NSD’s performance in real-world applications, posing risks to cable safety. In response, this paper conducts a robustness evaluation on an integrated cable-NSD system, taking into account various potential uncertainties. Specifically, the uncertain parameters are described by interval variables. Consequently, an interval model is constructed to delineate the boundaries of cable dynamic responses when subjected to these uncertainties. The model’s accuracy is validated against experimental results. Subsequent simulations involve assessing interval responses for both single- and multimode cable vibrations under varying uncertainties. Finally, the NSD’s robustness concerning cable vibration control is evaluated using the model, which incorporates the first-passage theory. This analysis delves into the relationships among confidence levels, performance measures, and the variation range of uncertainties. The results indicate that for single-mode vibration control, there is a 90% confidence level that the damping ratio reduction remains within 10%. As for multimode vibration control, a 90% confidence level is established that the amplification falls within 17%.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Structural Control & Health Monitoring
Structural Control & Health Monitoring 工程技术-工程:土木
CiteScore
9.50
自引率
13.00%
发文量
234
审稿时长
8 months
期刊介绍: The Journal Structural Control and Health Monitoring encompasses all theoretical and technological aspects of structural control, structural health monitoring theory and smart materials and structures. The journal focuses on aerospace, civil, infrastructure and mechanical engineering applications. Original contributions based on analytical, computational and experimental methods are solicited in three main areas: monitoring, control, and smart materials and structures, covering subjects such as system identification, health monitoring, health diagnostics, multi-functional materials, signal processing, sensor technology, passive, active and semi active control schemes and implementations, shape memory alloys, piezoelectrics and mechatronics. Also of interest are actuator design, dynamic systems, dynamic stability, artificial intelligence tools, data acquisition, wireless communications, measurements, MEMS/NEMS sensors for local damage detection, optical fibre sensors for health monitoring, remote control of monitoring systems, sensor-logger combinations for mobile applications, corrosion sensors, scour indicators and experimental techniques.
期刊最新文献
Deflection Prediction of a Rail-Cum-Road Suspension Bridge Under Multiple Operational Loads With Improved GPR and FSF Evaluation Method for Bearing Capacity of Fine-Grained Soil Subgrade Based on Multiple Moduli 3D Laser Scanning-Based Tension Assessment for Bridge Cables Considering Point Cloud Density Damage Identification in Large-Scale Bridge Girders Using Output-Only Modal Flexibility–Based Deflections and Span-Similar Virtual Beam Models A Multiple-Point Deformation Monitoring Model for Ultrahigh Arch Dams Using Temperature Lag and Optimized Gaussian Process Regression
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1