Sreenath Nair , Nicholas S. Selvo , Abigail Stolarski , Brandon Klee , Sara M. Federico , Clinton F. Stewart
{"title":"定量测定实体瘤患儿血浆样本中脂质体伊立替康和SN-38的浓度:使用低温保护剂溶液增强脂质体的稳定性。","authors":"Sreenath Nair , Nicholas S. Selvo , Abigail Stolarski , Brandon Klee , Sara M. Federico , Clinton F. Stewart","doi":"10.1016/j.jchromb.2024.124273","DOIUrl":null,"url":null,"abstract":"<div><p>Preclinical studies have demonstrated that liposomal irinotecan (CPT-11), a topoisomerase I inhibitor, has broad activity against adult cancers, including pancreatic, gastric, colon, lung, glioma, ovarian, and breast cancer. Encapsulation of irinotecan into liposomes can modify its pharmacokinetic properties dramatically. Also, the pharmacokinetic profiles of liposomal drug formulations are not fully understood; thus, bioanalytical methods are needed to separate and quantify nonencapsulated vs. encapsulated concentrations. In this study, two robust, specific, and sensitive LC-MS/MS methods were developed and validated to separate and quantify the nonencapsulated CPT-11 (NE-CPT-11) from the sum-total CPT-11 (T-CPT-11) and its major metabolite, SN-38, in human plasma after intravenous administration of liposomal irinotecan. NE-CPT-11 and SN-38 were separated from plasma samples by using solid-phase extraction, and T-CPT-11 was measured by protein precipitation. The liposomal CPT-11 formulation was unstable during sample storage and handling, resulting in elevated NE-CPT-11 concentration. To improve the stability of liposomal CPT-11, a cryoprotectant solution was added to human plasma samples prior to storage and processing. CPT-11, SN-38, and their respective internal standards, CPT-11-d10 and SN-38-d3, were chromatographically separated on a reversed-phase C<sub>18</sub> analytical column. The drugs were detected on a triple quadrupole mass spectrometer in the positive MRM ion mode by monitoring the transitions 587.3 > 124.1 (CPT-11) and 393.0 > 349.1 (SN-38). The calibration curves demonstrated a good fit across the concentration ranges of 10–5000 ng/mL for T-CPT-11, 2.5–250 ng/mL for NE-CPT-11, and 1–500 ng/mL for SN-38. The accuracy and precision were within the acceptable limits, matrix effects were nonsignificant, recoveries were consistent and reproducible, and the analytes were stable under all tested storage conditions. Finally, the LC-MS/MS methods were successfully applied in a phase I clinical pharmacokinetic study of nanoliposomal irinotecan (Onivyde®) in pediatric patients with recurrent solid malignancies or Ewing sarcoma.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":"1245 ","pages":"Article 124273"},"PeriodicalIF":2.8000,"publicationDate":"2024-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative determination of liposomal irinotecan and SN-38 concentrations in plasma samples from children with solid tumors: Use of a cryoprotectant solution to enhance liposome stability\",\"authors\":\"Sreenath Nair , Nicholas S. Selvo , Abigail Stolarski , Brandon Klee , Sara M. Federico , Clinton F. Stewart\",\"doi\":\"10.1016/j.jchromb.2024.124273\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Preclinical studies have demonstrated that liposomal irinotecan (CPT-11), a topoisomerase I inhibitor, has broad activity against adult cancers, including pancreatic, gastric, colon, lung, glioma, ovarian, and breast cancer. Encapsulation of irinotecan into liposomes can modify its pharmacokinetic properties dramatically. Also, the pharmacokinetic profiles of liposomal drug formulations are not fully understood; thus, bioanalytical methods are needed to separate and quantify nonencapsulated vs. encapsulated concentrations. In this study, two robust, specific, and sensitive LC-MS/MS methods were developed and validated to separate and quantify the nonencapsulated CPT-11 (NE-CPT-11) from the sum-total CPT-11 (T-CPT-11) and its major metabolite, SN-38, in human plasma after intravenous administration of liposomal irinotecan. NE-CPT-11 and SN-38 were separated from plasma samples by using solid-phase extraction, and T-CPT-11 was measured by protein precipitation. The liposomal CPT-11 formulation was unstable during sample storage and handling, resulting in elevated NE-CPT-11 concentration. To improve the stability of liposomal CPT-11, a cryoprotectant solution was added to human plasma samples prior to storage and processing. CPT-11, SN-38, and their respective internal standards, CPT-11-d10 and SN-38-d3, were chromatographically separated on a reversed-phase C<sub>18</sub> analytical column. The drugs were detected on a triple quadrupole mass spectrometer in the positive MRM ion mode by monitoring the transitions 587.3 > 124.1 (CPT-11) and 393.0 > 349.1 (SN-38). The calibration curves demonstrated a good fit across the concentration ranges of 10–5000 ng/mL for T-CPT-11, 2.5–250 ng/mL for NE-CPT-11, and 1–500 ng/mL for SN-38. The accuracy and precision were within the acceptable limits, matrix effects were nonsignificant, recoveries were consistent and reproducible, and the analytes were stable under all tested storage conditions. Finally, the LC-MS/MS methods were successfully applied in a phase I clinical pharmacokinetic study of nanoliposomal irinotecan (Onivyde®) in pediatric patients with recurrent solid malignancies or Ewing sarcoma.</p></div>\",\"PeriodicalId\":348,\"journal\":{\"name\":\"Journal of Chromatography B\",\"volume\":\"1245 \",\"pages\":\"Article 124273\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1570023224002824\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023224002824","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Quantitative determination of liposomal irinotecan and SN-38 concentrations in plasma samples from children with solid tumors: Use of a cryoprotectant solution to enhance liposome stability
Preclinical studies have demonstrated that liposomal irinotecan (CPT-11), a topoisomerase I inhibitor, has broad activity against adult cancers, including pancreatic, gastric, colon, lung, glioma, ovarian, and breast cancer. Encapsulation of irinotecan into liposomes can modify its pharmacokinetic properties dramatically. Also, the pharmacokinetic profiles of liposomal drug formulations are not fully understood; thus, bioanalytical methods are needed to separate and quantify nonencapsulated vs. encapsulated concentrations. In this study, two robust, specific, and sensitive LC-MS/MS methods were developed and validated to separate and quantify the nonencapsulated CPT-11 (NE-CPT-11) from the sum-total CPT-11 (T-CPT-11) and its major metabolite, SN-38, in human plasma after intravenous administration of liposomal irinotecan. NE-CPT-11 and SN-38 were separated from plasma samples by using solid-phase extraction, and T-CPT-11 was measured by protein precipitation. The liposomal CPT-11 formulation was unstable during sample storage and handling, resulting in elevated NE-CPT-11 concentration. To improve the stability of liposomal CPT-11, a cryoprotectant solution was added to human plasma samples prior to storage and processing. CPT-11, SN-38, and their respective internal standards, CPT-11-d10 and SN-38-d3, were chromatographically separated on a reversed-phase C18 analytical column. The drugs were detected on a triple quadrupole mass spectrometer in the positive MRM ion mode by monitoring the transitions 587.3 > 124.1 (CPT-11) and 393.0 > 349.1 (SN-38). The calibration curves demonstrated a good fit across the concentration ranges of 10–5000 ng/mL for T-CPT-11, 2.5–250 ng/mL for NE-CPT-11, and 1–500 ng/mL for SN-38. The accuracy and precision were within the acceptable limits, matrix effects were nonsignificant, recoveries were consistent and reproducible, and the analytes were stable under all tested storage conditions. Finally, the LC-MS/MS methods were successfully applied in a phase I clinical pharmacokinetic study of nanoliposomal irinotecan (Onivyde®) in pediatric patients with recurrent solid malignancies or Ewing sarcoma.
期刊介绍:
The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis.
Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches.
Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.