{"title":"在 3D-EBSD 中使用相干孪生边界作为内部参考的配准算法。","authors":"Heng Li, Shuang Xia, Qin Bai, Tingguang Liu, Yong Zhang","doi":"10.1111/jmi.13352","DOIUrl":null,"url":null,"abstract":"<p>A three-dimensional (3D) microstructural volume is reconstructed from a stack of two-dimensional sections which was obtained by serial sectioning coupled with electron back scattering diffraction (EBSD) mapping of a 316L austenitic stainless steel. A new alignment algorithm named linear translation by minimising the indicator (LTMI) is proposed to reduce the translational misalignments between adjacent sections by referencing to coherent twin boundaries which are flat and lying on {111} planes. The angular difference between the measured orientation of a flat twin boundary and that of the {111} plane is used as an indicator of the accuracy of the alignment operations. This indicator is minimised through linear translations of the centroids of triangular facets, which constitute grain boundaries at a distance not restricted by the in-plane step size of the EBSD maps. And hence the systematic trend in the translational misalignments can be effectively reduced. The LTMI alignment procedure proposed herein effectively corrects the misalignments remained by other methods on a 3D-EBSD data prepared using serial sectioning methods. The accuracy in distinguishing between coherent and incoherent twin boundaries is significantly improved.</p>","PeriodicalId":16484,"journal":{"name":"Journal of microscopy","volume":"297 1","pages":"43-56"},"PeriodicalIF":1.5000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An alignment algorithm using coherent twin boundaries as internal reference in 3D-EBSD\",\"authors\":\"Heng Li, Shuang Xia, Qin Bai, Tingguang Liu, Yong Zhang\",\"doi\":\"10.1111/jmi.13352\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A three-dimensional (3D) microstructural volume is reconstructed from a stack of two-dimensional sections which was obtained by serial sectioning coupled with electron back scattering diffraction (EBSD) mapping of a 316L austenitic stainless steel. A new alignment algorithm named linear translation by minimising the indicator (LTMI) is proposed to reduce the translational misalignments between adjacent sections by referencing to coherent twin boundaries which are flat and lying on {111} planes. The angular difference between the measured orientation of a flat twin boundary and that of the {111} plane is used as an indicator of the accuracy of the alignment operations. This indicator is minimised through linear translations of the centroids of triangular facets, which constitute grain boundaries at a distance not restricted by the in-plane step size of the EBSD maps. And hence the systematic trend in the translational misalignments can be effectively reduced. The LTMI alignment procedure proposed herein effectively corrects the misalignments remained by other methods on a 3D-EBSD data prepared using serial sectioning methods. The accuracy in distinguishing between coherent and incoherent twin boundaries is significantly improved.</p>\",\"PeriodicalId\":16484,\"journal\":{\"name\":\"Journal of microscopy\",\"volume\":\"297 1\",\"pages\":\"43-56\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of microscopy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jmi.13352\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MICROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of microscopy","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jmi.13352","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MICROSCOPY","Score":null,"Total":0}
An alignment algorithm using coherent twin boundaries as internal reference in 3D-EBSD
A three-dimensional (3D) microstructural volume is reconstructed from a stack of two-dimensional sections which was obtained by serial sectioning coupled with electron back scattering diffraction (EBSD) mapping of a 316L austenitic stainless steel. A new alignment algorithm named linear translation by minimising the indicator (LTMI) is proposed to reduce the translational misalignments between adjacent sections by referencing to coherent twin boundaries which are flat and lying on {111} planes. The angular difference between the measured orientation of a flat twin boundary and that of the {111} plane is used as an indicator of the accuracy of the alignment operations. This indicator is minimised through linear translations of the centroids of triangular facets, which constitute grain boundaries at a distance not restricted by the in-plane step size of the EBSD maps. And hence the systematic trend in the translational misalignments can be effectively reduced. The LTMI alignment procedure proposed herein effectively corrects the misalignments remained by other methods on a 3D-EBSD data prepared using serial sectioning methods. The accuracy in distinguishing between coherent and incoherent twin boundaries is significantly improved.
期刊介绍:
The Journal of Microscopy is the oldest journal dedicated to the science of microscopy and the only peer-reviewed publication of the Royal Microscopical Society. It publishes papers that report on the very latest developments in microscopy such as advances in microscopy techniques or novel areas of application. The Journal does not seek to publish routine applications of microscopy or specimen preparation even though the submission may otherwise have a high scientific merit.
The scope covers research in the physical and biological sciences and covers imaging methods using light, electrons, X-rays and other radiations as well as atomic force and near field techniques. Interdisciplinary research is welcome. Papers pertaining to microscopy are also welcomed on optical theory, spectroscopy, novel specimen preparation and manipulation methods and image recording, processing and analysis including dynamic analysis of living specimens.
Publication types include full papers, hot topic fast tracked communications and review articles. Authors considering submitting a review article should contact the editorial office first.