{"title":"用于工厂供热系统的多热源热泵耦合储能系统性能研究","authors":"","doi":"10.1016/j.enconman.2024.118917","DOIUrl":null,"url":null,"abstract":"<div><p>CO<sub>2</sub> air source heat pump (CASHP) faces challenges of performance degradation caused by the high return water temperature and the low ambient temperature for building heating. This study proposed a novel multi-heat source heat pump system (MHSHP) that combined with a CO<sub>2</sub> air source heat pumps (CASHP) and ground source heat pumps (GSHP) with the implementation of a thermal storage tank. The performance and CO<sub>2</sub> emissions of both CASHP and MHSHP systems were investigated by applying a plant factory located in Beijing, China. The effects of user-side parameters and ambient temperature were explored with the storage water temperatures ranging from 20 °C to 40 °C. The results demonstrated that the heating performance of the CASHP improved with an increase of user water flow rate and ambient temperatures, while it decreased as the storage water temperature increased. At the flow rate of 1.1 m<sup>3</sup>/h, the increase of the compressor frequency from 40 Hz to 60 Hz led to a significant improvement in heating capacity by 53.3 %, and a reduction in COP by 23.3 %. When the user-side water flow ratio decreased or the total flow rate increased, the COP of the MHSHP system showed improvement and outperformed that of the CASHP system, with an increase ranging from 46.9 % to 61.5 %. Additionally, it exhibits reduced sensitivity to ambient temperature fluctuations, resulting in a decrease in COP variability from 33.3 % to 20.6 %. Moreover, the CO<sub>2</sub> emissions of the system decrease as the COP increases, with significant reduction of 69.2 %.</p></div>","PeriodicalId":11664,"journal":{"name":"Energy Conversion and Management","volume":null,"pages":null},"PeriodicalIF":9.9000,"publicationDate":"2024-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on performance of a multi-heat source heat pump coupled energy storage system for plant factory heating system\",\"authors\":\"\",\"doi\":\"10.1016/j.enconman.2024.118917\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>CO<sub>2</sub> air source heat pump (CASHP) faces challenges of performance degradation caused by the high return water temperature and the low ambient temperature for building heating. This study proposed a novel multi-heat source heat pump system (MHSHP) that combined with a CO<sub>2</sub> air source heat pumps (CASHP) and ground source heat pumps (GSHP) with the implementation of a thermal storage tank. The performance and CO<sub>2</sub> emissions of both CASHP and MHSHP systems were investigated by applying a plant factory located in Beijing, China. The effects of user-side parameters and ambient temperature were explored with the storage water temperatures ranging from 20 °C to 40 °C. The results demonstrated that the heating performance of the CASHP improved with an increase of user water flow rate and ambient temperatures, while it decreased as the storage water temperature increased. At the flow rate of 1.1 m<sup>3</sup>/h, the increase of the compressor frequency from 40 Hz to 60 Hz led to a significant improvement in heating capacity by 53.3 %, and a reduction in COP by 23.3 %. When the user-side water flow ratio decreased or the total flow rate increased, the COP of the MHSHP system showed improvement and outperformed that of the CASHP system, with an increase ranging from 46.9 % to 61.5 %. Additionally, it exhibits reduced sensitivity to ambient temperature fluctuations, resulting in a decrease in COP variability from 33.3 % to 20.6 %. Moreover, the CO<sub>2</sub> emissions of the system decrease as the COP increases, with significant reduction of 69.2 %.</p></div>\",\"PeriodicalId\":11664,\"journal\":{\"name\":\"Energy Conversion and Management\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":9.9000,\"publicationDate\":\"2024-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0196890424008586\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0196890424008586","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Study on performance of a multi-heat source heat pump coupled energy storage system for plant factory heating system
CO2 air source heat pump (CASHP) faces challenges of performance degradation caused by the high return water temperature and the low ambient temperature for building heating. This study proposed a novel multi-heat source heat pump system (MHSHP) that combined with a CO2 air source heat pumps (CASHP) and ground source heat pumps (GSHP) with the implementation of a thermal storage tank. The performance and CO2 emissions of both CASHP and MHSHP systems were investigated by applying a plant factory located in Beijing, China. The effects of user-side parameters and ambient temperature were explored with the storage water temperatures ranging from 20 °C to 40 °C. The results demonstrated that the heating performance of the CASHP improved with an increase of user water flow rate and ambient temperatures, while it decreased as the storage water temperature increased. At the flow rate of 1.1 m3/h, the increase of the compressor frequency from 40 Hz to 60 Hz led to a significant improvement in heating capacity by 53.3 %, and a reduction in COP by 23.3 %. When the user-side water flow ratio decreased or the total flow rate increased, the COP of the MHSHP system showed improvement and outperformed that of the CASHP system, with an increase ranging from 46.9 % to 61.5 %. Additionally, it exhibits reduced sensitivity to ambient temperature fluctuations, resulting in a decrease in COP variability from 33.3 % to 20.6 %. Moreover, the CO2 emissions of the system decrease as the COP increases, with significant reduction of 69.2 %.
期刊介绍:
The journal Energy Conversion and Management provides a forum for publishing original contributions and comprehensive technical review articles of interdisciplinary and original research on all important energy topics.
The topics considered include energy generation, utilization, conversion, storage, transmission, conservation, management and sustainability. These topics typically involve various types of energy such as mechanical, thermal, nuclear, chemical, electromagnetic, magnetic and electric. These energy types cover all known energy resources, including renewable resources (e.g., solar, bio, hydro, wind, geothermal and ocean energy), fossil fuels and nuclear resources.