Hounsfield单位值对支气管内超声诊断恶性/良性纵隔淋巴腺病和肿块鉴别的影响

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-08-13 eCollection Date: 2024-01-01 DOI:10.2147/CMAR.S473653
Savaş Gegin, Ahmet Cemal Pazarlı, Burcu Özdemir, Levent Özdemir, Esra Arslan Aksu
{"title":"Hounsfield单位值对支气管内超声诊断恶性/良性纵隔淋巴腺病和肿块鉴别的影响","authors":"Savaş Gegin, Ahmet Cemal Pazarlı, Burcu Özdemir, Levent Özdemir, Esra Arslan Aksu","doi":"10.2147/CMAR.S473653","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>In cases where standardized maximum uptake (SUVmax) values in positron emission tomography (PET-CT) were not sufficient to differentiate mediastinal lymphadenopathy and masses from malignant or benign, the contribution of Hounsfield unit (HU) values in thorax computed tomography to the diagnosis was evaluated.</p><p><strong>Material method: </strong>The study was conducted by evaluating the data of 182 patients between 2019 and 2023. HU values on non-contrast thorax computed tomography and PET-CT SUV<sub>max</sub> values of biopsied masses and lymph nodes were compared with histopathological diagnoses.</p><p><strong>Results: </strong>Patients, 58 females (31.9%) and 124 males (68.1%), who underwent EBUS were included in the study. Biopsies were taken from 233 stations (199 lymph nodes, 34 masses) from 182 patients. A total of 135 of the biopsies taken from 233 stations were histopathologically malignant and 98 were benign. While PET-CT SUV<sub>max</sub> values of cases with benign histopathology were 4.5 ± 3.5, it was 7.6 ± 4.2 in patients with malignant pathology (p<0.05). The HU value on non-contrast thorax tomography in patients with benign histopathology was 43.1 ± 15.7, and in patients with malignant histopathology it was 40.5 ± 13.7 (p>0.05). When HU was compared according to lung cancer type, it was found to be significantly higher in non-small cell lung cancer (p=0.035). A weak (r=0.182) positive and significant relationship (p<0.01) was found between PET-CT values and HU values in thorax computed tomography.</p><p><strong>Conclusion: </strong>While positron emission tomography maintains its importance in the differentiation of mediastinal lymphadenopathy and masses from malignant to non-malignant, it was concluded that HU values in computed tomography are not sufficient to distinguish malignant/non-malignant.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"16 ","pages":"1013-1020"},"PeriodicalIF":4.6000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11330239/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Effect of Hounsfield Unit Value on the Differentiation of Malignant/Benign Mediastinal Lymphadenopathy and Masses Diagnosed by Endobronchial Ultrasonography.\",\"authors\":\"Savaş Gegin, Ahmet Cemal Pazarlı, Burcu Özdemir, Levent Özdemir, Esra Arslan Aksu\",\"doi\":\"10.2147/CMAR.S473653\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>In cases where standardized maximum uptake (SUVmax) values in positron emission tomography (PET-CT) were not sufficient to differentiate mediastinal lymphadenopathy and masses from malignant or benign, the contribution of Hounsfield unit (HU) values in thorax computed tomography to the diagnosis was evaluated.</p><p><strong>Material method: </strong>The study was conducted by evaluating the data of 182 patients between 2019 and 2023. HU values on non-contrast thorax computed tomography and PET-CT SUV<sub>max</sub> values of biopsied masses and lymph nodes were compared with histopathological diagnoses.</p><p><strong>Results: </strong>Patients, 58 females (31.9%) and 124 males (68.1%), who underwent EBUS were included in the study. Biopsies were taken from 233 stations (199 lymph nodes, 34 masses) from 182 patients. A total of 135 of the biopsies taken from 233 stations were histopathologically malignant and 98 were benign. While PET-CT SUV<sub>max</sub> values of cases with benign histopathology were 4.5 ± 3.5, it was 7.6 ± 4.2 in patients with malignant pathology (p<0.05). The HU value on non-contrast thorax tomography in patients with benign histopathology was 43.1 ± 15.7, and in patients with malignant histopathology it was 40.5 ± 13.7 (p>0.05). When HU was compared according to lung cancer type, it was found to be significantly higher in non-small cell lung cancer (p=0.035). A weak (r=0.182) positive and significant relationship (p<0.01) was found between PET-CT values and HU values in thorax computed tomography.</p><p><strong>Conclusion: </strong>While positron emission tomography maintains its importance in the differentiation of mediastinal lymphadenopathy and masses from malignant to non-malignant, it was concluded that HU values in computed tomography are not sufficient to distinguish malignant/non-malignant.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":\"16 \",\"pages\":\"1013-1020\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-08-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11330239/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2147/CMAR.S473653\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2147/CMAR.S473653","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目的:在正电子发射计算机断层扫描(PET-CT)的标准化最大摄取值(SUVmax)不足以区分纵隔淋巴结病变和肿块是恶性还是良性的情况下,评估胸部计算机断层扫描的Hounsfield单位(HU)值对诊断的贡献:研究通过评估2019年至2023年期间182名患者的数据进行。将非对比胸部计算机断层扫描的 HU 值以及活检肿块和淋巴结的 PET-CT SUVmax 值与组织病理学诊断进行比较:58名女性(31.9%)和124名男性(68.1%)患者接受了EBUS检查。活检取自 182 名患者的 233 个部位(199 个淋巴结、34 个肿块)。从 233 个部位提取的活检组织病理学结果显示,其中 135 例为恶性,98 例为良性。良性组织病理学病例的 PET-CT SUVmax 值为 4.5 ± 3.5,而恶性病理学病例的 SUVmax 值为 7.6 ± 4.2(P0.05)。根据肺癌类型比较 HU 值时发现,非小细胞肺癌患者的 HU 值明显更高(P=0.035)。两者之间存在微弱(r=0.182)的显著正相关关系(pConclusion):虽然正电子发射断层扫描在纵隔淋巴结病和肿块的恶性与非恶性鉴别中仍具有重要意义,但结论是计算机断层扫描的 HU 值不足以区分恶性/非恶性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Effect of Hounsfield Unit Value on the Differentiation of Malignant/Benign Mediastinal Lymphadenopathy and Masses Diagnosed by Endobronchial Ultrasonography.

Aim: In cases where standardized maximum uptake (SUVmax) values in positron emission tomography (PET-CT) were not sufficient to differentiate mediastinal lymphadenopathy and masses from malignant or benign, the contribution of Hounsfield unit (HU) values in thorax computed tomography to the diagnosis was evaluated.

Material method: The study was conducted by evaluating the data of 182 patients between 2019 and 2023. HU values on non-contrast thorax computed tomography and PET-CT SUVmax values of biopsied masses and lymph nodes were compared with histopathological diagnoses.

Results: Patients, 58 females (31.9%) and 124 males (68.1%), who underwent EBUS were included in the study. Biopsies were taken from 233 stations (199 lymph nodes, 34 masses) from 182 patients. A total of 135 of the biopsies taken from 233 stations were histopathologically malignant and 98 were benign. While PET-CT SUVmax values of cases with benign histopathology were 4.5 ± 3.5, it was 7.6 ± 4.2 in patients with malignant pathology (p<0.05). The HU value on non-contrast thorax tomography in patients with benign histopathology was 43.1 ± 15.7, and in patients with malignant histopathology it was 40.5 ± 13.7 (p>0.05). When HU was compared according to lung cancer type, it was found to be significantly higher in non-small cell lung cancer (p=0.035). A weak (r=0.182) positive and significant relationship (p<0.01) was found between PET-CT values and HU values in thorax computed tomography.

Conclusion: While positron emission tomography maintains its importance in the differentiation of mediastinal lymphadenopathy and masses from malignant to non-malignant, it was concluded that HU values in computed tomography are not sufficient to distinguish malignant/non-malignant.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1