肝素-琼脂提取增强型荧光色聚体-凝血酶原复合报告物可灵敏、快速地检测功能性抗凝血酶。

IF 8.2 1区 化学 Q1 CHEMISTRY, ANALYTICAL ACS Sensors Pub Date : 2024-09-27 Epub Date: 2024-08-23 DOI:10.1021/acssensors.4c01294
He Yan, Zimu Tian, Emma Ziegenbein, Ying Liu, Amanda Santana, Adam S Veige, Bruce Spiess, Weihong Tan, Yong Zeng
{"title":"肝素-琼脂提取增强型荧光色聚体-凝血酶原复合报告物可灵敏、快速地检测功能性抗凝血酶。","authors":"He Yan, Zimu Tian, Emma Ziegenbein, Ying Liu, Amanda Santana, Adam S Veige, Bruce Spiess, Weihong Tan, Yong Zeng","doi":"10.1021/acssensors.4c01294","DOIUrl":null,"url":null,"abstract":"<p><p>Antithrombin (AT) deficiency in the extracorporeal circulation during cardiac surgery leads to uncontrolled inflammation and vascular damage in patients. AT levels decrease in sepsis, major trauma, extracorporeal membrane oxygenation, and eclampsia. Monitoring plasma AT levels facilitates the accurate restoration of AT to baseline values through precise supplementation. Traditional methods of chromogenic assay and enzyme-linked immunosorbent assay (ELISA) kits encounter challenges, such as interference, inconsistency, and delayed response times, making real-time, reliable antithrombin monitoring a clinical gap. To address this critical need, we develop a heparin-bead extraction enhanced fluoroGenic aptamer-thrombin composite reporter (HExGATOR) for the rapid, sensitive, and precise detection of functional AT in plasma. Our design employs thrombin-binding aptamers and a fluorescence \"turn on\" technology such that a signal is produced upon the interaction of AT with the otherwise \"turned off\" aptamer-thrombin complex. The prominent signal-background interference originating from plasma is remarkably diminished by using a heparin-bead solid-phase extraction of AT. We achieved highly sensitive and rapid detection of AT in 5 to 20 min with a limit of detection of 15.11 nM. This approach offers a promising alternative to traditional AT tests in clinical settings, potentially facilitating personalized anticoagulant therapy.</p>","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":null,"pages":null},"PeriodicalIF":8.2000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Heparin-Bead Extraction Enhanced Fluorogenic Aptamer-Thrombin Composite Reporter Enables Sensitive and Rapid Detection of Functional Antithrombin.\",\"authors\":\"He Yan, Zimu Tian, Emma Ziegenbein, Ying Liu, Amanda Santana, Adam S Veige, Bruce Spiess, Weihong Tan, Yong Zeng\",\"doi\":\"10.1021/acssensors.4c01294\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Antithrombin (AT) deficiency in the extracorporeal circulation during cardiac surgery leads to uncontrolled inflammation and vascular damage in patients. AT levels decrease in sepsis, major trauma, extracorporeal membrane oxygenation, and eclampsia. Monitoring plasma AT levels facilitates the accurate restoration of AT to baseline values through precise supplementation. Traditional methods of chromogenic assay and enzyme-linked immunosorbent assay (ELISA) kits encounter challenges, such as interference, inconsistency, and delayed response times, making real-time, reliable antithrombin monitoring a clinical gap. To address this critical need, we develop a heparin-bead extraction enhanced fluoroGenic aptamer-thrombin composite reporter (HExGATOR) for the rapid, sensitive, and precise detection of functional AT in plasma. Our design employs thrombin-binding aptamers and a fluorescence \\\"turn on\\\" technology such that a signal is produced upon the interaction of AT with the otherwise \\\"turned off\\\" aptamer-thrombin complex. The prominent signal-background interference originating from plasma is remarkably diminished by using a heparin-bead solid-phase extraction of AT. We achieved highly sensitive and rapid detection of AT in 5 to 20 min with a limit of detection of 15.11 nM. This approach offers a promising alternative to traditional AT tests in clinical settings, potentially facilitating personalized anticoagulant therapy.</p>\",\"PeriodicalId\":24,\"journal\":{\"name\":\"ACS Sensors\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2024-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Sensors\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acssensors.4c01294\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/23 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.4c01294","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/23 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

心脏手术体外循环中抗凝血酶(AT)的缺乏会导致患者出现无法控制的炎症和血管损伤。在败血症、重大创伤、体外膜氧合和子痫时,AT 水平会下降。监测血浆 AT 水平有助于通过精确补充 AT 恢复到基线值。传统的色原测定法和酶联免疫吸附测定(ELISA)试剂盒会遇到干扰、不一致和响应时间延迟等挑战,因此实时、可靠的抗凝血酶监测成为临床空白。为了满足这一关键需求,我们开发了肝素珠提取增强型荧光基因拟合物-凝血酶复合报告物(HExGATOR),用于快速、灵敏、精确地检测血浆中的功能性抗凝血酶。我们的设计采用了凝血酶结合适配体和荧光 "开启 "技术,这样当AT与原本 "关闭 "的适配体-凝血酶复合物相互作用时就会产生信号。使用肝素珠固相萃取 AT,可显著减少来自血浆的明显信号-背景干扰。我们在 5 至 20 分钟内实现了对 AT 的高灵敏度和快速检测,检测限为 15.11 nM。在临床环境中,这种方法有望替代传统的AT检测方法,为个性化抗凝治疗提供潜在的便利。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Heparin-Bead Extraction Enhanced Fluorogenic Aptamer-Thrombin Composite Reporter Enables Sensitive and Rapid Detection of Functional Antithrombin.

Antithrombin (AT) deficiency in the extracorporeal circulation during cardiac surgery leads to uncontrolled inflammation and vascular damage in patients. AT levels decrease in sepsis, major trauma, extracorporeal membrane oxygenation, and eclampsia. Monitoring plasma AT levels facilitates the accurate restoration of AT to baseline values through precise supplementation. Traditional methods of chromogenic assay and enzyme-linked immunosorbent assay (ELISA) kits encounter challenges, such as interference, inconsistency, and delayed response times, making real-time, reliable antithrombin monitoring a clinical gap. To address this critical need, we develop a heparin-bead extraction enhanced fluoroGenic aptamer-thrombin composite reporter (HExGATOR) for the rapid, sensitive, and precise detection of functional AT in plasma. Our design employs thrombin-binding aptamers and a fluorescence "turn on" technology such that a signal is produced upon the interaction of AT with the otherwise "turned off" aptamer-thrombin complex. The prominent signal-background interference originating from plasma is remarkably diminished by using a heparin-bead solid-phase extraction of AT. We achieved highly sensitive and rapid detection of AT in 5 to 20 min with a limit of detection of 15.11 nM. This approach offers a promising alternative to traditional AT tests in clinical settings, potentially facilitating personalized anticoagulant therapy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Sensors
ACS Sensors Chemical Engineering-Bioengineering
CiteScore
14.50
自引率
3.40%
发文量
372
期刊介绍: ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.
期刊最新文献
Enhanced NO2 Gas Sensing in Nanocrystalline MoS2 via Swift Heavy Ion Irradiation: An Experimental and DFT Study High Response and ppb-Level Detection toward Hydrogen Sensing by Palladium-Doped α-Fe2O3 Nanotubes Surface Blocking-Based Potentiometric Biosensor for Detection of E. coli ATCC 15597 Using Phage MS2 as a Receptor Digital Clustered Regularly Interspaced Short Palindromic Repeats-Powered Biosensor Concept without Target Amplification Using Single-Impact Electrochemistry. Self-Powered, Flexible, Wireless and Intelligent Human Health Management System Based on Natural Recyclable Materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1