磷化钴(Co2P)纳米粒子的尺寸控制合成及其在碳纤维/Co2P 复合材料非酶葡萄糖传感器中的应用

IF 6.5 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Sensors and Actuators Reports Pub Date : 2024-08-16 DOI:10.1016/j.snr.2024.100235
Tania P. Brito , Nicole Butto-Miranda , Andrónico Neira-Carrillo , Claudia Yáñez , Soledad Bollo , Domingo Ruíz-León
{"title":"磷化钴(Co2P)纳米粒子的尺寸控制合成及其在碳纤维/Co2P 复合材料非酶葡萄糖传感器中的应用","authors":"Tania P. Brito ,&nbsp;Nicole Butto-Miranda ,&nbsp;Andrónico Neira-Carrillo ,&nbsp;Claudia Yáñez ,&nbsp;Soledad Bollo ,&nbsp;Domingo Ruíz-León","doi":"10.1016/j.snr.2024.100235","DOIUrl":null,"url":null,"abstract":"<div><p>In this study, we synthesized Co<sub>2</sub>P nanoparticles using a solid-state phosphorization method and evaluated the electrocatalytic response to glucose oxidation reaction (GORs). The influence of synthesis conditions on the particle size, morphology of Co<sub>2</sub>P species and formation of byproducts is discussed. A lower molar ratio of the phosphorus precursor leads to a decrease in the generation of byproducts. In addition, the calcination temperature and time greatly influence the purity level of the Co<sub>2</sub>P species and its particle size. Thus, we obtained three pure Co<sub>2</sub>P nanoparticles with different sizes and morphologies. Significant differences in their electrocatalytic activity against the GOR are observed depending on the size of the particles, being the smaller ones the most efficient. Based on Tafel analysis, a higher catalytic activity was observed for the carbon fibre (CF)/Co<sub>2</sub>P composite compared to Co<sub>2</sub>P, which presented a greater onset potential and low response in current density. Tafel slopes close to 120 mV/dec were obtained for both materials, indicating that the mechanism is independent of the type of Co<sub>2</sub>P-based material used. Finally, the performance of the GCE/CF/Co<sub>2</sub>P sensor was demonstrated by amperometric measurements, with a sensitivity of 409 µAmM<sup>-1</sup>cm<sup>-2</sup>, a linear range between 39.4 µM and 150 µM, and a detection limit of 0.97 µM, analytical characteristics better than those obtained for other cobalt phosphide-based sensors reported in the literature. In addition, the GCE/CF/Co<sub>2</sub>P sensor shows excellent selectivity and demonstrated to be competitive compared to other Co-based non-enzymatic glucose sensors.</p></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"8 ","pages":"Article 100235"},"PeriodicalIF":6.5000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666053924000511/pdfft?md5=05f50d90c27d250e05ba6544e577c123&pid=1-s2.0-S2666053924000511-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Size-controlled synthesis of cobalt phosphide (Co2P) nanoparticles and their application in non-enzymatic glucose sensors via a carbon fiber/Co2P composite\",\"authors\":\"Tania P. Brito ,&nbsp;Nicole Butto-Miranda ,&nbsp;Andrónico Neira-Carrillo ,&nbsp;Claudia Yáñez ,&nbsp;Soledad Bollo ,&nbsp;Domingo Ruíz-León\",\"doi\":\"10.1016/j.snr.2024.100235\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this study, we synthesized Co<sub>2</sub>P nanoparticles using a solid-state phosphorization method and evaluated the electrocatalytic response to glucose oxidation reaction (GORs). The influence of synthesis conditions on the particle size, morphology of Co<sub>2</sub>P species and formation of byproducts is discussed. A lower molar ratio of the phosphorus precursor leads to a decrease in the generation of byproducts. In addition, the calcination temperature and time greatly influence the purity level of the Co<sub>2</sub>P species and its particle size. Thus, we obtained three pure Co<sub>2</sub>P nanoparticles with different sizes and morphologies. Significant differences in their electrocatalytic activity against the GOR are observed depending on the size of the particles, being the smaller ones the most efficient. Based on Tafel analysis, a higher catalytic activity was observed for the carbon fibre (CF)/Co<sub>2</sub>P composite compared to Co<sub>2</sub>P, which presented a greater onset potential and low response in current density. Tafel slopes close to 120 mV/dec were obtained for both materials, indicating that the mechanism is independent of the type of Co<sub>2</sub>P-based material used. Finally, the performance of the GCE/CF/Co<sub>2</sub>P sensor was demonstrated by amperometric measurements, with a sensitivity of 409 µAmM<sup>-1</sup>cm<sup>-2</sup>, a linear range between 39.4 µM and 150 µM, and a detection limit of 0.97 µM, analytical characteristics better than those obtained for other cobalt phosphide-based sensors reported in the literature. In addition, the GCE/CF/Co<sub>2</sub>P sensor shows excellent selectivity and demonstrated to be competitive compared to other Co-based non-enzymatic glucose sensors.</p></div>\",\"PeriodicalId\":426,\"journal\":{\"name\":\"Sensors and Actuators Reports\",\"volume\":\"8 \",\"pages\":\"Article 100235\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666053924000511/pdfft?md5=05f50d90c27d250e05ba6544e577c123&pid=1-s2.0-S2666053924000511-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666053924000511\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053924000511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究采用固态磷化法合成了 Co2P 纳米粒子,并评估了其对葡萄糖氧化反应(GORs)的电催化响应。我们讨论了合成条件对粒度、Co2P 物种形态和副产物形成的影响。磷前驱体的摩尔比越低,副产物的生成就越少。此外,煅烧温度和时间对 Co2P 物种的纯度和粒度也有很大影响。因此,我们获得了三种不同尺寸和形态的纯 Co2P 纳米粒子。根据颗粒大小的不同,它们对 GOR 的电催化活性也存在显著差异,其中较小的颗粒效率最高。根据塔菲尔分析,碳纤维(CF)/Co2P 复合材料的催化活性高于 Co2P,后者的起始电位更高,电流密度响应更低。两种材料的塔菲尔斜率都接近 120 mV/dec,这表明其机理与所使用的 Co2P 基材料类型无关。最后,GCE/CF/Co2P 传感器的性能通过安培测量得到了证明,其灵敏度为 409 µAmM-1cm-2,线性范围为 39.4 µM 至 150 µM,检测限为 0.97 µM,分析特性优于文献中报道的其他基于磷化钴的传感器。此外,GCE/CF/Co2P 传感器还显示出极佳的选择性,与其他钴基非酶葡萄糖传感器相比具有竞争力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Size-controlled synthesis of cobalt phosphide (Co2P) nanoparticles and their application in non-enzymatic glucose sensors via a carbon fiber/Co2P composite

In this study, we synthesized Co2P nanoparticles using a solid-state phosphorization method and evaluated the electrocatalytic response to glucose oxidation reaction (GORs). The influence of synthesis conditions on the particle size, morphology of Co2P species and formation of byproducts is discussed. A lower molar ratio of the phosphorus precursor leads to a decrease in the generation of byproducts. In addition, the calcination temperature and time greatly influence the purity level of the Co2P species and its particle size. Thus, we obtained three pure Co2P nanoparticles with different sizes and morphologies. Significant differences in their electrocatalytic activity against the GOR are observed depending on the size of the particles, being the smaller ones the most efficient. Based on Tafel analysis, a higher catalytic activity was observed for the carbon fibre (CF)/Co2P composite compared to Co2P, which presented a greater onset potential and low response in current density. Tafel slopes close to 120 mV/dec were obtained for both materials, indicating that the mechanism is independent of the type of Co2P-based material used. Finally, the performance of the GCE/CF/Co2P sensor was demonstrated by amperometric measurements, with a sensitivity of 409 µAmM-1cm-2, a linear range between 39.4 µM and 150 µM, and a detection limit of 0.97 µM, analytical characteristics better than those obtained for other cobalt phosphide-based sensors reported in the literature. In addition, the GCE/CF/Co2P sensor shows excellent selectivity and demonstrated to be competitive compared to other Co-based non-enzymatic glucose sensors.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
期刊最新文献
A highly sensitive microfluidic biosensor for rapid and accurate detection of Salmonella in raw chicken products Enhancing nitrous oxide chemiresistive sensing performance by reducing ionic Oxygen species adsorption in Gold functionalized Tungsten Trioxide nanofibers Critical review of hydrogen cyanide (HCN) sensors and their applications 1D supramolecular assembly-induced emission and colorimetry toward precise onsite mercury(II) detection Rapid detection of human adenovirus by multiple cross displacement amplification combined with nanoparticle-based biosensor platform
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1