{"title":"混合型肱骨反向肩关节置换术:在评估肱骨近端应力屏蔽和相关临床结果时采用骨移植和骨骺固定术的前瞻性研究","authors":"Roberto Pareyon MD , Helen Ingoe MBBS, FRCS Eng , Mohammad N. Jomaa MD , Kristine Italia FPOA , Jashint Maharaj FRSPH , Sarah L. Whitehouse PhD , Kenneth Cutbush MBBS, FRACS, FAOrthoA , Ashish Gupta MBBS, MSc, FRACS, FAOrthoA","doi":"10.1053/j.sart.2024.05.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>A significant proportion of revisions after reverse shoulder arthroplasty (RSA) is attributed to the humeral component. The purpose of this study is to evaluate the radiographic and clinical outcomes of the hybrid humerus technique for RSA using a Grammont-style humeral prosthesis in an onlay fashion with metaphyseal bone impaction grafting technique and undersized stem to avoid humeral stress shielding, notching, and loosening.</p></div><div><h3>Methods</h3><p>This is a prospective case series of patients who underwent RSA using the hybrid humerus technique with a minimum 2-year follow-up. Key steps of this technique include the use of undersized Grammont-style stem, impaction bone grafting of the proximal 5 cm of the humerus, and adjusting the height and offset of the stem depending on the patient stature, desired lateralization and distalization, and joint and soft tissue tension. Radiographic assessments were performed immediately after surgery, and at 1 and 2 years after surgery. These included assessment of metaphyseal and diaphyseal filling ratio, cortical narrowing, radiolucent lines, cortical lucencies, spot welding, scapular notching, and stem alignment. Preoperative and 2-year postoperative clinical assessments included American Shoulder and Elbow Surgeons score, Constant-Murley Score, University of California Los Angeles score, visual analog scale for pain, and active range of motion. Correlation between the filling ratios and clinical outcomes were also evaluated.</p></div><div><h3>Results</h3><p>Sixty-one patients were included in the study. The average metaphyseal and diaphyseal filling ratio on the postoperative X-ray was 0.66 and 0.54, and 0.67 and 0.54 at 2 years, respectively. Stress shielding was graded as none in 24 (40.7%), mild in 33 (55.9%), and moderate in 2 (3.4%). No stem had a change in position of more than 5°. At 2 years of follow-up, no humeral implant loosening was noted, with only 2 (3.4%) of the stems at risk of loosening. Thirty-nine (66.1%) had no notching, 14 (23.7%) were graded as mild, and 6 (10.2%) had moderate signs of notching. All clinical assessments significantly improved at 2 years (<em>P</em> < .001), with a weak negative correlation between visual analog scale and metaphyseal filling ratio (r = −0.268, <em>P</em> = .036) but none between diaphyseal filling ratio and clinical outcomes.</p></div><div><h3>Conclusion</h3><p>The hybrid humerus technique of metaphyseal bone grafting with a low filling ratio stem presents a promising solution for reducing humeral complications in RSA. This technique demonstrates a low incidence of stress shielding and loosening, with excellent clinical outcomes at 2 years.</p></div>","PeriodicalId":39885,"journal":{"name":"Seminars in Arthroplasty","volume":"34 3","pages":"Pages 797-806"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1045452724000713/pdfft?md5=ce0f7ece85c74763621fecd2b7f9dc06&pid=1-s2.0-S1045452724000713-main.pdf","citationCount":"0","resultStr":"{\"title\":\"The hybrid humerus reverse shoulder arthroplasty: a prospective study of bone grafting and metaphyseal fixation with undersized stem in the assessment of proximal humeral stress shielding and associated clinical outcome\",\"authors\":\"Roberto Pareyon MD , Helen Ingoe MBBS, FRCS Eng , Mohammad N. Jomaa MD , Kristine Italia FPOA , Jashint Maharaj FRSPH , Sarah L. Whitehouse PhD , Kenneth Cutbush MBBS, FRACS, FAOrthoA , Ashish Gupta MBBS, MSc, FRACS, FAOrthoA\",\"doi\":\"10.1053/j.sart.2024.05.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>A significant proportion of revisions after reverse shoulder arthroplasty (RSA) is attributed to the humeral component. The purpose of this study is to evaluate the radiographic and clinical outcomes of the hybrid humerus technique for RSA using a Grammont-style humeral prosthesis in an onlay fashion with metaphyseal bone impaction grafting technique and undersized stem to avoid humeral stress shielding, notching, and loosening.</p></div><div><h3>Methods</h3><p>This is a prospective case series of patients who underwent RSA using the hybrid humerus technique with a minimum 2-year follow-up. Key steps of this technique include the use of undersized Grammont-style stem, impaction bone grafting of the proximal 5 cm of the humerus, and adjusting the height and offset of the stem depending on the patient stature, desired lateralization and distalization, and joint and soft tissue tension. Radiographic assessments were performed immediately after surgery, and at 1 and 2 years after surgery. These included assessment of metaphyseal and diaphyseal filling ratio, cortical narrowing, radiolucent lines, cortical lucencies, spot welding, scapular notching, and stem alignment. Preoperative and 2-year postoperative clinical assessments included American Shoulder and Elbow Surgeons score, Constant-Murley Score, University of California Los Angeles score, visual analog scale for pain, and active range of motion. Correlation between the filling ratios and clinical outcomes were also evaluated.</p></div><div><h3>Results</h3><p>Sixty-one patients were included in the study. The average metaphyseal and diaphyseal filling ratio on the postoperative X-ray was 0.66 and 0.54, and 0.67 and 0.54 at 2 years, respectively. Stress shielding was graded as none in 24 (40.7%), mild in 33 (55.9%), and moderate in 2 (3.4%). No stem had a change in position of more than 5°. At 2 years of follow-up, no humeral implant loosening was noted, with only 2 (3.4%) of the stems at risk of loosening. Thirty-nine (66.1%) had no notching, 14 (23.7%) were graded as mild, and 6 (10.2%) had moderate signs of notching. All clinical assessments significantly improved at 2 years (<em>P</em> < .001), with a weak negative correlation between visual analog scale and metaphyseal filling ratio (r = −0.268, <em>P</em> = .036) but none between diaphyseal filling ratio and clinical outcomes.</p></div><div><h3>Conclusion</h3><p>The hybrid humerus technique of metaphyseal bone grafting with a low filling ratio stem presents a promising solution for reducing humeral complications in RSA. This technique demonstrates a low incidence of stress shielding and loosening, with excellent clinical outcomes at 2 years.</p></div>\",\"PeriodicalId\":39885,\"journal\":{\"name\":\"Seminars in Arthroplasty\",\"volume\":\"34 3\",\"pages\":\"Pages 797-806\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1045452724000713/pdfft?md5=ce0f7ece85c74763621fecd2b7f9dc06&pid=1-s2.0-S1045452724000713-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Seminars in Arthroplasty\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1045452724000713\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1045452724000713","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
The hybrid humerus reverse shoulder arthroplasty: a prospective study of bone grafting and metaphyseal fixation with undersized stem in the assessment of proximal humeral stress shielding and associated clinical outcome
Background
A significant proportion of revisions after reverse shoulder arthroplasty (RSA) is attributed to the humeral component. The purpose of this study is to evaluate the radiographic and clinical outcomes of the hybrid humerus technique for RSA using a Grammont-style humeral prosthesis in an onlay fashion with metaphyseal bone impaction grafting technique and undersized stem to avoid humeral stress shielding, notching, and loosening.
Methods
This is a prospective case series of patients who underwent RSA using the hybrid humerus technique with a minimum 2-year follow-up. Key steps of this technique include the use of undersized Grammont-style stem, impaction bone grafting of the proximal 5 cm of the humerus, and adjusting the height and offset of the stem depending on the patient stature, desired lateralization and distalization, and joint and soft tissue tension. Radiographic assessments were performed immediately after surgery, and at 1 and 2 years after surgery. These included assessment of metaphyseal and diaphyseal filling ratio, cortical narrowing, radiolucent lines, cortical lucencies, spot welding, scapular notching, and stem alignment. Preoperative and 2-year postoperative clinical assessments included American Shoulder and Elbow Surgeons score, Constant-Murley Score, University of California Los Angeles score, visual analog scale for pain, and active range of motion. Correlation between the filling ratios and clinical outcomes were also evaluated.
Results
Sixty-one patients were included in the study. The average metaphyseal and diaphyseal filling ratio on the postoperative X-ray was 0.66 and 0.54, and 0.67 and 0.54 at 2 years, respectively. Stress shielding was graded as none in 24 (40.7%), mild in 33 (55.9%), and moderate in 2 (3.4%). No stem had a change in position of more than 5°. At 2 years of follow-up, no humeral implant loosening was noted, with only 2 (3.4%) of the stems at risk of loosening. Thirty-nine (66.1%) had no notching, 14 (23.7%) were graded as mild, and 6 (10.2%) had moderate signs of notching. All clinical assessments significantly improved at 2 years (P < .001), with a weak negative correlation between visual analog scale and metaphyseal filling ratio (r = −0.268, P = .036) but none between diaphyseal filling ratio and clinical outcomes.
Conclusion
The hybrid humerus technique of metaphyseal bone grafting with a low filling ratio stem presents a promising solution for reducing humeral complications in RSA. This technique demonstrates a low incidence of stress shielding and loosening, with excellent clinical outcomes at 2 years.