连续腰椎与非连续腰椎的骨矿物质密度监测:马尼托巴省 BMD 登记

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-08-13 DOI:10.1016/j.jocd.2024.101520
Auryan Szalat , Harold Rosen , William D. Leslie
{"title":"连续腰椎与非连续腰椎的骨矿物质密度监测:马尼托巴省 BMD 登记","authors":"Auryan Szalat ,&nbsp;Harold Rosen ,&nbsp;William D. Leslie","doi":"10.1016/j.jocd.2024.101520","DOIUrl":null,"url":null,"abstract":"<div><p><em>Introduction:</em> Only change in bone mineral density (BMD) on repeat DXA that exceeds the 95% least significant change (LSC) should be considered clinically meaningful. Frequently lumbar spine DXA must be reported after omitting vertebrae with localized structural artifact, which reduces measurement precision. Previous reports have raised concerns of higher least significant change (LSC) when spine BMD is based on non-contiguous rather than contiguous vertebrae. The current study was performed to compare lumbar spine LSC and BMD response to intervening anti-osteoporosis medication use from non-contiguous versus contiguous vertebrae.</p><p><em>Methodology:</em> LSCs for lumbar spine DXA based on L1-L4 and all combinations of non-contiguous and contiguous vertebrae were calculated using 879 scan-pairs from the Manitoba BMD Program. We compared BMD change from these regions, overall and in relation to intervening anti-osteoporosis medication use, in 11,722 patients who had 2 DXA examinations.</p><p><em>Results:</em> LSCs were slightly greater when calculated from combinations of fewer than 4 vertebrae, but there was no meaningful difference between contiguous versus non-contiguous vertebrae. There were consistently high correlations between lumbar spine BMD change from L1-L4 and all combinations of continuous and non-contiguous vertebrae (all Pearson r≥ 0.9, p&lt;0.001). Percentage changes in spine BMD and the fraction with treatment-concordant change exceeding the LSC were similar using contiguous or non-contiguous vertebrae.</p><p><em>Conclusions:</em> Lumbar spine BMD change can be assessed from 2 or 3 non-contiguous vertebrae when clinically necessary, and precision in such cases is similar to using contiguous vertebrae. Non-contiguous vertebrae can detect treatment-concordant changes similar in spine BMD to contiguous vertebrae.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bone Mineral Density Monitoring in Contiguous versus Non-Contiguous Lumbar Vertebrae: The Manitoba BMD Registry\",\"authors\":\"Auryan Szalat ,&nbsp;Harold Rosen ,&nbsp;William D. Leslie\",\"doi\":\"10.1016/j.jocd.2024.101520\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><em>Introduction:</em> Only change in bone mineral density (BMD) on repeat DXA that exceeds the 95% least significant change (LSC) should be considered clinically meaningful. Frequently lumbar spine DXA must be reported after omitting vertebrae with localized structural artifact, which reduces measurement precision. Previous reports have raised concerns of higher least significant change (LSC) when spine BMD is based on non-contiguous rather than contiguous vertebrae. The current study was performed to compare lumbar spine LSC and BMD response to intervening anti-osteoporosis medication use from non-contiguous versus contiguous vertebrae.</p><p><em>Methodology:</em> LSCs for lumbar spine DXA based on L1-L4 and all combinations of non-contiguous and contiguous vertebrae were calculated using 879 scan-pairs from the Manitoba BMD Program. We compared BMD change from these regions, overall and in relation to intervening anti-osteoporosis medication use, in 11,722 patients who had 2 DXA examinations.</p><p><em>Results:</em> LSCs were slightly greater when calculated from combinations of fewer than 4 vertebrae, but there was no meaningful difference between contiguous versus non-contiguous vertebrae. There were consistently high correlations between lumbar spine BMD change from L1-L4 and all combinations of continuous and non-contiguous vertebrae (all Pearson r≥ 0.9, p&lt;0.001). Percentage changes in spine BMD and the fraction with treatment-concordant change exceeding the LSC were similar using contiguous or non-contiguous vertebrae.</p><p><em>Conclusions:</em> Lumbar spine BMD change can be assessed from 2 or 3 non-contiguous vertebrae when clinically necessary, and precision in such cases is similar to using contiguous vertebrae. Non-contiguous vertebrae can detect treatment-concordant changes similar in spine BMD to contiguous vertebrae.</p></div>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-08-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1094695024000556\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1094695024000556","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

简介:只有在重复 DXA 检查中,骨矿物质密度(BMD)的变化超过 95% 的最小显著变化(LSC),才能被认为具有临床意义。腰椎 DXA 通常必须在省略有局部结构伪影的椎体后才能报告,这就降低了测量的精确度。以前的报告曾担心,如果脊柱 BMD 是基于非连续而非连续的椎体,则最小显著变化(LSC)会更高。本研究旨在比较非连续椎体与连续椎体的腰椎 LSC 和 BMD 对使用抗骨质疏松症药物干预的反应:我们使用马尼托巴省 BMD 计划的 879 对扫描数据计算了基于 L1-L4 的腰椎 DXA LSC 以及非连续和连续椎体的所有组合。我们对接受过两次 DXA 检查的 11,722 名患者的总体 BMD 变化以及与干预性抗骨质疏松症药物使用的关系进行了比较:根据少于 4 个椎骨的组合计算出的 LSC 值略大于根据少于 4 个椎骨的组合计算出的 LSC 值,但连续椎骨与非连续椎骨之间没有明显差异。从 L1 到 L4 的腰椎 BMD 变化与连续和非连续椎体的所有组合之间始终存在高度相关性(所有 Pearson r 均≥ 0.9,p<0.001)。使用连续或非连续椎体时,脊柱 BMD 变化的百分比和治疗一致性变化超过 LSC 的比例相似:结论:在临床需要时,可通过 2 或 3 个非连续椎体评估腰椎 BMD 变化,其精确度与使用连续椎体相似。非连续椎体可以检测出与连续椎体相似的治疗一致性脊柱 BMD 变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bone Mineral Density Monitoring in Contiguous versus Non-Contiguous Lumbar Vertebrae: The Manitoba BMD Registry

Introduction: Only change in bone mineral density (BMD) on repeat DXA that exceeds the 95% least significant change (LSC) should be considered clinically meaningful. Frequently lumbar spine DXA must be reported after omitting vertebrae with localized structural artifact, which reduces measurement precision. Previous reports have raised concerns of higher least significant change (LSC) when spine BMD is based on non-contiguous rather than contiguous vertebrae. The current study was performed to compare lumbar spine LSC and BMD response to intervening anti-osteoporosis medication use from non-contiguous versus contiguous vertebrae.

Methodology: LSCs for lumbar spine DXA based on L1-L4 and all combinations of non-contiguous and contiguous vertebrae were calculated using 879 scan-pairs from the Manitoba BMD Program. We compared BMD change from these regions, overall and in relation to intervening anti-osteoporosis medication use, in 11,722 patients who had 2 DXA examinations.

Results: LSCs were slightly greater when calculated from combinations of fewer than 4 vertebrae, but there was no meaningful difference between contiguous versus non-contiguous vertebrae. There were consistently high correlations between lumbar spine BMD change from L1-L4 and all combinations of continuous and non-contiguous vertebrae (all Pearson r≥ 0.9, p<0.001). Percentage changes in spine BMD and the fraction with treatment-concordant change exceeding the LSC were similar using contiguous or non-contiguous vertebrae.

Conclusions: Lumbar spine BMD change can be assessed from 2 or 3 non-contiguous vertebrae when clinically necessary, and precision in such cases is similar to using contiguous vertebrae. Non-contiguous vertebrae can detect treatment-concordant changes similar in spine BMD to contiguous vertebrae.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Mentorship in academic musculoskeletal radiology: perspectives from a junior faculty member. Underlying synovial sarcoma undiagnosed for more than 20 years in a patient with regional pain: a case report. Sacrococcygeal chordoma with spontaneous regression due to a large hemorrhagic component. Associations of cumulative voriconazole dose, treatment duration, and alkaline phosphatase with voriconazole-induced periostitis. Can the presence of SLAP-5 lesions be predicted by using the critical shoulder angle in traumatic anterior shoulder instability?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1