{"title":"利用结构中的非对称电动场进行离子约束和分离,实现无损离子操作。","authors":"Cullen Greer, Zackary R. Kinlein, Brian H. Clowers","doi":"10.1002/rcm.9900","DOIUrl":null,"url":null,"abstract":"<div>\n \n <section>\n \n <h3> Rationale</h3>\n \n <p>TW-SLIM ion mobility separations have demonstrated exceptional resolution by leveraging long paths with minimal loss. All previously reported experiments have used electrode surfaces which are mirrored to generate symmetrically opposing electric fields for ion confinement. However, work with other planar ion optics indicates this may be unnecessary. This study explores conditions under which separations may be obtained using a SLIM with asymmetric electric fields.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The asymmetric field configuration was defined by applying a uniform DC potential to all electrodes of the top PCB of a standard TW-SLIM board pair, with no electrode placement modifications. This configuration was simulated in SIMION to assess transmission through the SLIM. A benchtop TW-SLIM instrument outfitted with a Faraday plate detector was modified likewise, so the top PCB had a uniform DC potential applied to all electrodes, while the bottom board was operated normally.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Simulations show full ion transmission for four different <i>m/z</i> ion populations over a range of DC biases applied to the “pusher” board. Likewise, the modified benchtop instrument is capable of transmitting, separating, and cycling ions with minimal losses. The effect of pusher strength on separation quality is explored, and comparisons between the standard and modified SLIM are made with respect to resolving the +2 and +3 charge states of neurotensin ions.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>A functional IMS instrument using asymmetric confining fields demonstrates additional field modifications may be a means to achieve additional functionality with limited interruption of the analysis. A TW-SLIM PCB specifically designed as a pusher board would benefit from minimized manufacturing cost, simplifying assembly, reducing drive electronics, and improved field consistency.</p>\n </section>\n </div>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"38 20","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/rcm.9900","citationCount":"0","resultStr":"{\"title\":\"Ion confinement and separation using asymmetric electrodynamic fields in structures for lossless ion manipulations\",\"authors\":\"Cullen Greer, Zackary R. Kinlein, Brian H. Clowers\",\"doi\":\"10.1002/rcm.9900\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <section>\\n \\n <h3> Rationale</h3>\\n \\n <p>TW-SLIM ion mobility separations have demonstrated exceptional resolution by leveraging long paths with minimal loss. All previously reported experiments have used electrode surfaces which are mirrored to generate symmetrically opposing electric fields for ion confinement. However, work with other planar ion optics indicates this may be unnecessary. This study explores conditions under which separations may be obtained using a SLIM with asymmetric electric fields.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>The asymmetric field configuration was defined by applying a uniform DC potential to all electrodes of the top PCB of a standard TW-SLIM board pair, with no electrode placement modifications. This configuration was simulated in SIMION to assess transmission through the SLIM. A benchtop TW-SLIM instrument outfitted with a Faraday plate detector was modified likewise, so the top PCB had a uniform DC potential applied to all electrodes, while the bottom board was operated normally.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Simulations show full ion transmission for four different <i>m/z</i> ion populations over a range of DC biases applied to the “pusher” board. Likewise, the modified benchtop instrument is capable of transmitting, separating, and cycling ions with minimal losses. The effect of pusher strength on separation quality is explored, and comparisons between the standard and modified SLIM are made with respect to resolving the +2 and +3 charge states of neurotensin ions.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>A functional IMS instrument using asymmetric confining fields demonstrates additional field modifications may be a means to achieve additional functionality with limited interruption of the analysis. A TW-SLIM PCB specifically designed as a pusher board would benefit from minimized manufacturing cost, simplifying assembly, reducing drive electronics, and improved field consistency.</p>\\n </section>\\n </div>\",\"PeriodicalId\":225,\"journal\":{\"name\":\"Rapid Communications in Mass Spectrometry\",\"volume\":\"38 20\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-08-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/rcm.9900\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rapid Communications in Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9900\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9900","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Ion confinement and separation using asymmetric electrodynamic fields in structures for lossless ion manipulations
Rationale
TW-SLIM ion mobility separations have demonstrated exceptional resolution by leveraging long paths with minimal loss. All previously reported experiments have used electrode surfaces which are mirrored to generate symmetrically opposing electric fields for ion confinement. However, work with other planar ion optics indicates this may be unnecessary. This study explores conditions under which separations may be obtained using a SLIM with asymmetric electric fields.
Methods
The asymmetric field configuration was defined by applying a uniform DC potential to all electrodes of the top PCB of a standard TW-SLIM board pair, with no electrode placement modifications. This configuration was simulated in SIMION to assess transmission through the SLIM. A benchtop TW-SLIM instrument outfitted with a Faraday plate detector was modified likewise, so the top PCB had a uniform DC potential applied to all electrodes, while the bottom board was operated normally.
Results
Simulations show full ion transmission for four different m/z ion populations over a range of DC biases applied to the “pusher” board. Likewise, the modified benchtop instrument is capable of transmitting, separating, and cycling ions with minimal losses. The effect of pusher strength on separation quality is explored, and comparisons between the standard and modified SLIM are made with respect to resolving the +2 and +3 charge states of neurotensin ions.
Conclusions
A functional IMS instrument using asymmetric confining fields demonstrates additional field modifications may be a means to achieve additional functionality with limited interruption of the analysis. A TW-SLIM PCB specifically designed as a pusher board would benefit from minimized manufacturing cost, simplifying assembly, reducing drive electronics, and improved field consistency.
期刊介绍:
Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.