磁动力超声弹性测量磁体设计的有限元分析模型及实验验证。

ArXiv Pub Date : 2024-08-14
Jacquelline Nyakunu, Christopher T Piatnichouk, Henry C Russell, Niels J van Duijnhoven, Benjamin E Levy
{"title":"磁动力超声弹性测量磁体设计的有限元分析模型及实验验证。","authors":"Jacquelline Nyakunu, Christopher T Piatnichouk, Henry C Russell, Niels J van Duijnhoven, Benjamin E Levy","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Magnetomotive ultrasound (MMUS) using magnetic nanoparticle contrast agents has shown promise for thrombosis imaging and quantitative elastometry via magnetomotive resonant acoustic spectroscopy (MRAS). Young's modulus measurements of smaller, stiffer thrombi require an MRAS system capable of generating forces at higher temporal frequencies. Solenoids with fewer turns, and thus less inductance, could improve high frequency performance, but the reduced force may compromise results. In this work, a computational model capable of predicting improved MRAS magnet configurations optimized for elastometry is presented and validated.</p><p><strong>Approach: </strong>Finite element analysis (FEA) was used to model the force and inductance of MRAS systems. The simulations incorporated both solenoid electromagnets and permanent magnets in three-dimensional steady-state, frequency domain, and time domain studies.</p><p><strong>Main results: </strong>The model successfully predicted a configuration in which permanent magnets could be used to increase the force supplied by an existing MRAS system. Accordingly, the displacement measured in a magnetically labeled validation phantom increased by a factor of 2.2 ± 0.3 when the force was predicted to increase by a factor of 2.2 ± 0.2. The model additionally identified a new solenoid configuration consisting of four smaller coils capable of providing sufficient force at higher driving frequencies.</p><p><strong>Significance: </strong>These results indicate two methods by which MRAS systems could be designed to deliver higher frequency magnetic forces without the need for experimental trial and error. Either the number of turns within each solenoid could be reduced while permanent magnets are added at precise locations, or a larger number of smaller solenoids could be used. These findings overcome a key challenge toward the goal of thrombosis elastometry via MMUS.</p>","PeriodicalId":93888,"journal":{"name":"ArXiv","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11343222/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Finite Element Analysis Model for Magnetomotive Ultrasound Elastometry Magnet Design with Experimental Validation.\",\"authors\":\"Jacquelline Nyakunu, Christopher T Piatnichouk, Henry C Russell, Niels J van Duijnhoven, Benjamin E Levy\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Magnetomotive ultrasound (MMUS) using magnetic nanoparticle contrast agents has shown promise for thrombosis imaging and quantitative elastometry via magnetomotive resonant acoustic spectroscopy (MRAS). Young's modulus measurements of smaller, stiffer thrombi require an MRAS system capable of generating forces at higher temporal frequencies. Solenoids with fewer turns, and thus less inductance, could improve high frequency performance, but the reduced force may compromise results. In this work, a computational model capable of predicting improved MRAS magnet configurations optimized for elastometry is presented and validated.</p><p><strong>Approach: </strong>Finite element analysis (FEA) was used to model the force and inductance of MRAS systems. The simulations incorporated both solenoid electromagnets and permanent magnets in three-dimensional steady-state, frequency domain, and time domain studies.</p><p><strong>Main results: </strong>The model successfully predicted a configuration in which permanent magnets could be used to increase the force supplied by an existing MRAS system. Accordingly, the displacement measured in a magnetically labeled validation phantom increased by a factor of 2.2 ± 0.3 when the force was predicted to increase by a factor of 2.2 ± 0.2. The model additionally identified a new solenoid configuration consisting of four smaller coils capable of providing sufficient force at higher driving frequencies.</p><p><strong>Significance: </strong>These results indicate two methods by which MRAS systems could be designed to deliver higher frequency magnetic forces without the need for experimental trial and error. Either the number of turns within each solenoid could be reduced while permanent magnets are added at precise locations, or a larger number of smaller solenoids could be used. These findings overcome a key challenge toward the goal of thrombosis elastometry via MMUS.</p>\",\"PeriodicalId\":93888,\"journal\":{\"name\":\"ArXiv\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11343222/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ArXiv\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ArXiv","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:使用磁性纳米粒子造影剂的磁动力超声(MMUS)有望通过磁动力共振声谱(MRAS)进行血栓成像和定量弹性测量。要测量较小、较硬血栓的杨氏模量,需要磁共振共振声学系统能够在较高的时间频率下产生力。匝数较少从而电感较小的螺线管可以提高高频性能,但减小的力可能会影响结果。在这项工作中,介绍并验证了一个计算模型,该模型能够预测为弹性测量优化的改进 MRAS 磁体配置:方法:使用有限元分析(FEA)对 MRAS 系统的力和电感进行建模。模拟将电磁铁和永磁体纳入三维稳态、频域和时域研究中:该模型成功预测了一种配置,在这种配置中,永久磁铁可用于增加现有 MRAS 系统提供的力。因此,当预测力增加 2.2 \pm 0.2$ 时,在磁标记验证模型中测得的位移增加了 2.2 \pm 0.3$。该模型还确定了一种新的螺线管配置,它由四个较小的线圈组成,能够在较高的驱动频率下提供足够的力:这些结果表明,有两种方法可用于设计 MRAS 系统,以提供更高频率的磁力,而无需进行试验和出错。要么减少每个螺线管的匝数,同时在精确位置添加永久磁铁,要么使用更多的小型螺线管。这些发现克服了通过 MMUS 实现血栓弹性测量目标的关键挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Finite Element Analysis Model for Magnetomotive Ultrasound Elastometry Magnet Design with Experimental Validation.

Objective: Magnetomotive ultrasound (MMUS) using magnetic nanoparticle contrast agents has shown promise for thrombosis imaging and quantitative elastometry via magnetomotive resonant acoustic spectroscopy (MRAS). Young's modulus measurements of smaller, stiffer thrombi require an MRAS system capable of generating forces at higher temporal frequencies. Solenoids with fewer turns, and thus less inductance, could improve high frequency performance, but the reduced force may compromise results. In this work, a computational model capable of predicting improved MRAS magnet configurations optimized for elastometry is presented and validated.

Approach: Finite element analysis (FEA) was used to model the force and inductance of MRAS systems. The simulations incorporated both solenoid electromagnets and permanent magnets in three-dimensional steady-state, frequency domain, and time domain studies.

Main results: The model successfully predicted a configuration in which permanent magnets could be used to increase the force supplied by an existing MRAS system. Accordingly, the displacement measured in a magnetically labeled validation phantom increased by a factor of 2.2 ± 0.3 when the force was predicted to increase by a factor of 2.2 ± 0.2. The model additionally identified a new solenoid configuration consisting of four smaller coils capable of providing sufficient force at higher driving frequencies.

Significance: These results indicate two methods by which MRAS systems could be designed to deliver higher frequency magnetic forces without the need for experimental trial and error. Either the number of turns within each solenoid could be reduced while permanent magnets are added at precise locations, or a larger number of smaller solenoids could be used. These findings overcome a key challenge toward the goal of thrombosis elastometry via MMUS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Categorization of 33 computational methods to detect spatially variable genes from spatially resolved transcriptomics data. A Geometric Tension Dynamics Model of Epithelial Convergent Extension. Learning Molecular Representation in a Cell. Ankle Exoskeletons May Hinder Standing Balance in Simple Models of Older and Younger Adults. Nonparametric causal inference for optogenetics: sequential excursion effects for dynamic regimes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1