具有时间一致性的血管内超声图像分割深度学习模型。

Hyeonmin Kim, June-Goo Lee, Gyu-Jun Jeong, Geunyoung Lee, Hyunseok Min, Hyungjoo Cho, Daegyu Min, Seung-Whan Lee, Jun Hwan Cho, Sungsoo Cho, Soo-Jin Kang
{"title":"具有时间一致性的血管内超声图像分割深度学习模型。","authors":"Hyeonmin Kim, June-Goo Lee, Gyu-Jun Jeong, Geunyoung Lee, Hyunseok Min, Hyungjoo Cho, Daegyu Min, Seung-Whan Lee, Jun Hwan Cho, Sungsoo Cho, Soo-Jin Kang","doi":"10.1007/s10554-024-03221-9","DOIUrl":null,"url":null,"abstract":"<p><p>This study was conducted to develop and validate a deep learning model for delineating intravascular ultrasound (IVUS) images of coronary arteries.Using a total of 1240 40-MHz IVUS pullbacks with 191,407 frames, the model for lumen and external elastic membrane (EEM) segmentation was developed. Both frame- and vessel-level performances and clinical impact of the model on 3-year cardiovascular events were evaluated in the independent data sets. In the test set, the Dice similarity coefficients (DSC) were 0.966 ± 0.025 and 0.982 ± 0.017 for the lumen and EEM, respectively. Even at sites of extensive attenuation, the frame-level performance was excellent (DSCs > 0.96 for the lumen and EEM). The model (vs. the expert) showed a better temporal consistency for contouring the EEM. The agreement between the model- vs. the expert-derived cross-sectional and volumetric measurements was excellent in the independent retrospective cohort (all, intra-class coefficients > 0.94). The model-derived percent atheroma volume > 52.5% (area under curve 0.70, sensitivity 71% and specificity 67%) and plaque burden at the minimal lumen area site (area under curve 0.72, sensitivity 72% and specificity 66%) best predicted 3-year cardiac death and nonculprit-related target vessel revascularization, respectively. In the stented segment, the DSCs > 0.96 for contouring lumen and EEM were achieved. Applied to the 60-MHz IVUS images, the DSCs were > 0.97. In the external cohort with 45-MHz IVUS, the DSCs were > 0.96. The deep learning model accurately delineated vascular geometry, which may be cost-saving and support clinical decision-making.</p>","PeriodicalId":94227,"journal":{"name":"The international journal of cardiovascular imaging","volume":" ","pages":"2283-2292"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Deep learning model for intravascular ultrasound image segmentation with temporal consistency.\",\"authors\":\"Hyeonmin Kim, June-Goo Lee, Gyu-Jun Jeong, Geunyoung Lee, Hyunseok Min, Hyungjoo Cho, Daegyu Min, Seung-Whan Lee, Jun Hwan Cho, Sungsoo Cho, Soo-Jin Kang\",\"doi\":\"10.1007/s10554-024-03221-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study was conducted to develop and validate a deep learning model for delineating intravascular ultrasound (IVUS) images of coronary arteries.Using a total of 1240 40-MHz IVUS pullbacks with 191,407 frames, the model for lumen and external elastic membrane (EEM) segmentation was developed. Both frame- and vessel-level performances and clinical impact of the model on 3-year cardiovascular events were evaluated in the independent data sets. In the test set, the Dice similarity coefficients (DSC) were 0.966 ± 0.025 and 0.982 ± 0.017 for the lumen and EEM, respectively. Even at sites of extensive attenuation, the frame-level performance was excellent (DSCs > 0.96 for the lumen and EEM). The model (vs. the expert) showed a better temporal consistency for contouring the EEM. The agreement between the model- vs. the expert-derived cross-sectional and volumetric measurements was excellent in the independent retrospective cohort (all, intra-class coefficients > 0.94). The model-derived percent atheroma volume > 52.5% (area under curve 0.70, sensitivity 71% and specificity 67%) and plaque burden at the minimal lumen area site (area under curve 0.72, sensitivity 72% and specificity 66%) best predicted 3-year cardiac death and nonculprit-related target vessel revascularization, respectively. In the stented segment, the DSCs > 0.96 for contouring lumen and EEM were achieved. Applied to the 60-MHz IVUS images, the DSCs were > 0.97. In the external cohort with 45-MHz IVUS, the DSCs were > 0.96. The deep learning model accurately delineated vascular geometry, which may be cost-saving and support clinical decision-making.</p>\",\"PeriodicalId\":94227,\"journal\":{\"name\":\"The international journal of cardiovascular imaging\",\"volume\":\" \",\"pages\":\"2283-2292\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The international journal of cardiovascular imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s10554-024-03221-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The international journal of cardiovascular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10554-024-03221-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/27 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

这项研究旨在开发和验证一种用于冠状动脉血管内超声(IVUS)图像分界的深度学习模型。利用总共1240个40兆赫IVUS回放和191,407个帧,开发了用于管腔和外部弹性膜(EEM)分割的模型。在独立数据集中评估了该模型在帧和血管层面的性能以及对3年心血管事件的临床影响。在测试集中,管腔和 EEM 的 Dice 相似系数 (DSC) 分别为 0.966 ± 0.025 和 0.982 ± 0.017。即使在广泛衰减的部位,帧级性能也非常出色(管腔和 EEM 的 DSCs > 0.96)。在绘制 EEM 的轮廓时,模型(与专家相比)显示出更好的时间一致性。在独立的回顾性队列中,模型与专家得出的横截面和容积测量值之间的一致性非常好(所有测量值的类内系数均大于 0.94)。模型得出的动脉粥样斑块体积百分比 > 52.5%(曲线下面积 0.70,灵敏度 71%,特异度 67%)和最小管腔面积部位的斑块负荷(曲线下面积 0.72,灵敏度 72%,特异度 66%)分别是 3 年心源性死亡和非斑块相关靶血管血运重建的最佳预测指标。在支架段,轮廓管腔和 EEM 的 DSC 均大于 0.96。应用 60-MHz IVUS 图像时,DSCs > 0.97。在使用 45-MHz IVUS 的外部队列中,DSC 均大于 0.96。深度学习模型准确地勾勒出了血管的几何形状,这可能会节约成本并支持临床决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Deep learning model for intravascular ultrasound image segmentation with temporal consistency.

This study was conducted to develop and validate a deep learning model for delineating intravascular ultrasound (IVUS) images of coronary arteries.Using a total of 1240 40-MHz IVUS pullbacks with 191,407 frames, the model for lumen and external elastic membrane (EEM) segmentation was developed. Both frame- and vessel-level performances and clinical impact of the model on 3-year cardiovascular events were evaluated in the independent data sets. In the test set, the Dice similarity coefficients (DSC) were 0.966 ± 0.025 and 0.982 ± 0.017 for the lumen and EEM, respectively. Even at sites of extensive attenuation, the frame-level performance was excellent (DSCs > 0.96 for the lumen and EEM). The model (vs. the expert) showed a better temporal consistency for contouring the EEM. The agreement between the model- vs. the expert-derived cross-sectional and volumetric measurements was excellent in the independent retrospective cohort (all, intra-class coefficients > 0.94). The model-derived percent atheroma volume > 52.5% (area under curve 0.70, sensitivity 71% and specificity 67%) and plaque burden at the minimal lumen area site (area under curve 0.72, sensitivity 72% and specificity 66%) best predicted 3-year cardiac death and nonculprit-related target vessel revascularization, respectively. In the stented segment, the DSCs > 0.96 for contouring lumen and EEM were achieved. Applied to the 60-MHz IVUS images, the DSCs were > 0.97. In the external cohort with 45-MHz IVUS, the DSCs were > 0.96. The deep learning model accurately delineated vascular geometry, which may be cost-saving and support clinical decision-making.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characterization of epicardial adipose tissue thickness and structure by ultrasound radiomics in acute and chronic coronary patients. Redundant and aneurysmal interatrial septum motion: a commentary on anatomical factors and clinical implications. Comparison of global and regional myocardial blood flow quantification using dynamic solid-state detector SPECT and Tc-99 m-sestamibi or Tc-99 m-tetrofosmin in a routine clinical setting. Myocardial extracellular volume fraction estimations using late enhancement CT in patients with atrial fibrillation: a comparative study with cardiac MR. When a common sore throat unmasks a rare disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1