利用多反转自旋和梯度回波磁共振成像技术在一次屏气或呼吸触发采集中同时绘制肝脏多参数图谱

IF 3.3 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Magnetic Resonance Imaging Pub Date : 2024-08-27 DOI:10.1002/jmri.29584
Mary Kate Manhard, Anandh Kilpattu Ramaniharan, Jean A Tkach, Andrew T Trout, Jonathan R Dillman, Amol S Pednekar
{"title":"利用多反转自旋和梯度回波磁共振成像技术在一次屏气或呼吸触发采集中同时绘制肝脏多参数图谱","authors":"Mary Kate Manhard, Anandh Kilpattu Ramaniharan, Jean A Tkach, Andrew T Trout, Jonathan R Dillman, Amol S Pednekar","doi":"10.1002/jmri.29584","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Quantitative parametric mapping is an increasingly important tool for noninvasive assessment of chronic liver disease. Conventional parametric mapping techniques require multiple breath-held acquisitions and provide limited anatomic coverage.</p><p><strong>Purpose: </strong>To investigate a multi-inversion spin and gradient echo (MI-SAGE) technique for simultaneous estimation of T<sub>1</sub>, T<sub>2</sub>, and T<sub>2</sub>* of the liver.</p><p><strong>Study type: </strong>Prospective.</p><p><strong>Subjects: </strong>Sixteen research participants, both adult and pediatric (age 17.5 ± 4.6 years, eight male), with and without known liver disease (seven asymptomatic healthy controls, two fibrotic liver disease, five steatotic liver disease, and two fibrotic and steatotic liver disease).</p><p><strong>Field strength/sequence: </strong>1.5 T, single breath-hold and respiratory triggered MI-SAGE, breath-hold modified Look-Locker inversion recovery (MOLLI, T<sub>1</sub> mapping), breath-hold gradient and spin echo (GRASE, T<sub>2</sub> mapping), and multiple gradient echo (mGRE, T<sub>2</sub>* mapping) sequences.</p><p><strong>Assessment: </strong>Agreement between hepatic T<sub>1</sub>, T<sub>2</sub>, and T<sub>2</sub>* estimated using MI-SAGE and conventional parametric mapping sequences was evaluated. Repeatability and reproducibility of MI-SAGE were evaluated using a same-session acquisition and second-session acquisition.</p><p><strong>Statistical tests: </strong>Bland-Altman analysis with bias assessment and limits of agreement (LOA) and intraclass correlation coefficients (ICC).</p><p><strong>Results: </strong>Hepatic T<sub>1</sub>, T<sub>2</sub>, and T<sub>2</sub>* estimates obtained using the MI-SAGE technique had mean biases of 72 (LOA: -22 to 166) msec, -3 (LOA: -10 to 5) msec, and 2 (LOA: -5 to 8) msec (single breath-hold) and 36 (LOA: -43 to 120) msec, -3 (LOA: -17 to 11) msec, and 4 (LOA: -3 to 11) msec (respiratory triggered), respectively, in comparison to conventional acquisitions using MOLLI, GRASE, and mGRE. All MI-SAGE estimates had strong repeatability and reproducibility (ICC > 0.72).</p><p><strong>Data conclusion: </strong>Hepatic T<sub>1</sub>, T<sub>2</sub>, and T<sub>2</sub>* estimates obtained using an MI-SAGE technique were comparable to conventional methods, although there was a 12%/6% for breath-hold/respiratory triggered underestimation of T<sub>1</sub> values compared to MOLLI. Both respiratory triggered and breath-hold MI-SAGE parameter maps demonstrated strong repeatability and reproducibility.</p><p><strong>Level of evidence: </strong>1 TECHNICAL EFFICACY: Stage 2.</p>","PeriodicalId":16140,"journal":{"name":"Journal of Magnetic Resonance Imaging","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous Multiparameter Mapping of the Liver in a Single Breath-Hold or Respiratory-Triggered Acquisition Using Multi-Inversion Spin and Gradient Echo MRI.\",\"authors\":\"Mary Kate Manhard, Anandh Kilpattu Ramaniharan, Jean A Tkach, Andrew T Trout, Jonathan R Dillman, Amol S Pednekar\",\"doi\":\"10.1002/jmri.29584\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Quantitative parametric mapping is an increasingly important tool for noninvasive assessment of chronic liver disease. Conventional parametric mapping techniques require multiple breath-held acquisitions and provide limited anatomic coverage.</p><p><strong>Purpose: </strong>To investigate a multi-inversion spin and gradient echo (MI-SAGE) technique for simultaneous estimation of T<sub>1</sub>, T<sub>2</sub>, and T<sub>2</sub>* of the liver.</p><p><strong>Study type: </strong>Prospective.</p><p><strong>Subjects: </strong>Sixteen research participants, both adult and pediatric (age 17.5 ± 4.6 years, eight male), with and without known liver disease (seven asymptomatic healthy controls, two fibrotic liver disease, five steatotic liver disease, and two fibrotic and steatotic liver disease).</p><p><strong>Field strength/sequence: </strong>1.5 T, single breath-hold and respiratory triggered MI-SAGE, breath-hold modified Look-Locker inversion recovery (MOLLI, T<sub>1</sub> mapping), breath-hold gradient and spin echo (GRASE, T<sub>2</sub> mapping), and multiple gradient echo (mGRE, T<sub>2</sub>* mapping) sequences.</p><p><strong>Assessment: </strong>Agreement between hepatic T<sub>1</sub>, T<sub>2</sub>, and T<sub>2</sub>* estimated using MI-SAGE and conventional parametric mapping sequences was evaluated. Repeatability and reproducibility of MI-SAGE were evaluated using a same-session acquisition and second-session acquisition.</p><p><strong>Statistical tests: </strong>Bland-Altman analysis with bias assessment and limits of agreement (LOA) and intraclass correlation coefficients (ICC).</p><p><strong>Results: </strong>Hepatic T<sub>1</sub>, T<sub>2</sub>, and T<sub>2</sub>* estimates obtained using the MI-SAGE technique had mean biases of 72 (LOA: -22 to 166) msec, -3 (LOA: -10 to 5) msec, and 2 (LOA: -5 to 8) msec (single breath-hold) and 36 (LOA: -43 to 120) msec, -3 (LOA: -17 to 11) msec, and 4 (LOA: -3 to 11) msec (respiratory triggered), respectively, in comparison to conventional acquisitions using MOLLI, GRASE, and mGRE. All MI-SAGE estimates had strong repeatability and reproducibility (ICC > 0.72).</p><p><strong>Data conclusion: </strong>Hepatic T<sub>1</sub>, T<sub>2</sub>, and T<sub>2</sub>* estimates obtained using an MI-SAGE technique were comparable to conventional methods, although there was a 12%/6% for breath-hold/respiratory triggered underestimation of T<sub>1</sub> values compared to MOLLI. Both respiratory triggered and breath-hold MI-SAGE parameter maps demonstrated strong repeatability and reproducibility.</p><p><strong>Level of evidence: </strong>1 TECHNICAL EFFICACY: Stage 2.</p>\",\"PeriodicalId\":16140,\"journal\":{\"name\":\"Journal of Magnetic Resonance Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jmri.29584\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jmri.29584","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:定量参数图谱是一种日益重要的慢性肝病无创评估工具。目的:研究一种同时估算肝脏 T1、T2 和 T2* 的多反转自旋和梯度回波(MI-SAGE)技术:研究对象16名研究参与者,包括成人和儿童(年龄17.5 ± 4.6岁,8名男性),患有和未患有已知肝病(7名无症状健康对照组、2名纤维化肝病患者、5名脂肪肝患者、2名纤维化和脂肪肝患者):1.5 T、单次屏气和呼吸触发 MI-SAGE、屏气改良 Look-Locker 反转恢复(MOLLI,T1 映射)、屏气梯度和自旋回波(GRASE,T2 映射)以及多重梯度回波(mGRE,T2* 映射)序列:评估:评估了使用 MI-SAGE 和传统参数测绘序列估算的肝脏 T1、T2 和 T2* 之间的一致性。使用同一次采集和第二次采集评估了 MI-SAGE 的重复性和再现性:结果:使用 MI-SAGE 技术获得的肝 T1、T2 和 T2* 估计值的平均偏差分别为 72(LOA:-22 至 166)毫秒、-3(LOA:-10 至 5)毫秒和 2(LOA:-5 至 8)毫秒(单次屏气)和 36(LOA:-43 至 120)毫秒(单次屏气):与使用 MOLLI、GRASE 和 mGRE 进行的传统采集相比,MI-SAGE 的估计值分别为-43 至 120 毫秒、-3(LOA:-17 至 11)毫秒和 4(LOA:-3 至 11)毫秒(呼吸触发)。所有 MI-SAGE 估计值都具有很高的重复性和再现性(ICC > 0.72):数据结论:使用 MI-SAGE 技术获得的肝脏 T1、T2 和 T2* 估计值与传统方法相当,但与 MOLLI 相比,屏气/呼吸触发的 T1 值低估了 12%/6%。呼吸触发和屏气 MI-SAGE 参数图均显示出很强的重复性和再现性:1 技术效率:第 2 阶段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simultaneous Multiparameter Mapping of the Liver in a Single Breath-Hold or Respiratory-Triggered Acquisition Using Multi-Inversion Spin and Gradient Echo MRI.

Background: Quantitative parametric mapping is an increasingly important tool for noninvasive assessment of chronic liver disease. Conventional parametric mapping techniques require multiple breath-held acquisitions and provide limited anatomic coverage.

Purpose: To investigate a multi-inversion spin and gradient echo (MI-SAGE) technique for simultaneous estimation of T1, T2, and T2* of the liver.

Study type: Prospective.

Subjects: Sixteen research participants, both adult and pediatric (age 17.5 ± 4.6 years, eight male), with and without known liver disease (seven asymptomatic healthy controls, two fibrotic liver disease, five steatotic liver disease, and two fibrotic and steatotic liver disease).

Field strength/sequence: 1.5 T, single breath-hold and respiratory triggered MI-SAGE, breath-hold modified Look-Locker inversion recovery (MOLLI, T1 mapping), breath-hold gradient and spin echo (GRASE, T2 mapping), and multiple gradient echo (mGRE, T2* mapping) sequences.

Assessment: Agreement between hepatic T1, T2, and T2* estimated using MI-SAGE and conventional parametric mapping sequences was evaluated. Repeatability and reproducibility of MI-SAGE were evaluated using a same-session acquisition and second-session acquisition.

Statistical tests: Bland-Altman analysis with bias assessment and limits of agreement (LOA) and intraclass correlation coefficients (ICC).

Results: Hepatic T1, T2, and T2* estimates obtained using the MI-SAGE technique had mean biases of 72 (LOA: -22 to 166) msec, -3 (LOA: -10 to 5) msec, and 2 (LOA: -5 to 8) msec (single breath-hold) and 36 (LOA: -43 to 120) msec, -3 (LOA: -17 to 11) msec, and 4 (LOA: -3 to 11) msec (respiratory triggered), respectively, in comparison to conventional acquisitions using MOLLI, GRASE, and mGRE. All MI-SAGE estimates had strong repeatability and reproducibility (ICC > 0.72).

Data conclusion: Hepatic T1, T2, and T2* estimates obtained using an MI-SAGE technique were comparable to conventional methods, although there was a 12%/6% for breath-hold/respiratory triggered underestimation of T1 values compared to MOLLI. Both respiratory triggered and breath-hold MI-SAGE parameter maps demonstrated strong repeatability and reproducibility.

Level of evidence: 1 TECHNICAL EFFICACY: Stage 2.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.70
自引率
6.80%
发文量
494
审稿时长
2 months
期刊介绍: The Journal of Magnetic Resonance Imaging (JMRI) is an international journal devoted to the timely publication of basic and clinical research, educational and review articles, and other information related to the diagnostic applications of magnetic resonance.
期刊最新文献
Assessing Visual Pathway White Matter Degeneration in Primary Open-Angle Glaucoma Using Multiple MRI Morphology and Diffusion Metrics. Abnormal Structural-Functional Coupling and MRI Alterations of Brain Network Topology in Progressive Supranuclear Palsy. Application of Myocardial Salvage Index as a Clinical Endpoint: Assessment Methods and Future Prospects. Glymphatic System in Preterm Neonates: Developmental Insights Following Birth Asphyxia. Editorial for "Discrimination Between Benign and Malignant Lesions With Restriction Spectrum Imaging MRI in a Breast Cancer Screening Cohort".
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1