多样本细胞显微镜中用于稳健延时漂移校正估算的无托帧对齐。

IF 2.7 Q3 IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY Journal of Imaging Pub Date : 2024-07-29 DOI:10.3390/jimaging10080181
Stefan Baar, Masahiro Kuragano, Naoki Nishishita, Kiyotaka Tokuraku, Shinya Watanabe
{"title":"多样本细胞显微镜中用于稳健延时漂移校正估算的无托帧对齐。","authors":"Stefan Baar, Masahiro Kuragano, Naoki Nishishita, Kiyotaka Tokuraku, Shinya Watanabe","doi":"10.3390/jimaging10080181","DOIUrl":null,"url":null,"abstract":"<p><p>When analyzing microscopic time-lapse observations, frame alignment is an essential task to visually understand the morphological and translation dynamics of cells and tissue. While in traditional single-sample microscopy, the region of interest (RoI) is fixed, multi-sample microscopy often uses a single microscope that scans multiple samples over a long period of time by laterally relocating the sample stage. Hence, the relocation of the optics induces a statistical RoI offset and can introduce jitter as well as drift, which results in a misaligned RoI for each sample's time-lapse observation (stage drift). We introduce a robust approach to automatically align all frames within a time-lapse observation and compensate for frame drift. In this study, we present a sub-pixel precise alignment approach based on recurrent all-pairs field transforms (RAFT); a deep network architecture for optical flow. We show that the RAFT model pre-trained on the Sintel dataset performed with near perfect precision for registration tasks on a set of ten contextually unrelated time-lapse observations containing 250 frames each. Our approach is robust for elastically undistorted and translation displaced (x,y) microscopic time-lapse observations and was tested on multiple samples with varying cell density, obtained using different devices. The approach only performed well for registration and not for tracking of the individual image components like cells and contaminants. We provide an open-source command-line application that corrects for stage drift and jitter.</p>","PeriodicalId":37035,"journal":{"name":"Journal of Imaging","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11355451/pdf/","citationCount":"0","resultStr":"{\"title\":\"Fiduciary-Free Frame Alignment for Robust Time-Lapse Drift Correction Estimation in Multi-Sample Cell Microscopy.\",\"authors\":\"Stefan Baar, Masahiro Kuragano, Naoki Nishishita, Kiyotaka Tokuraku, Shinya Watanabe\",\"doi\":\"10.3390/jimaging10080181\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>When analyzing microscopic time-lapse observations, frame alignment is an essential task to visually understand the morphological and translation dynamics of cells and tissue. While in traditional single-sample microscopy, the region of interest (RoI) is fixed, multi-sample microscopy often uses a single microscope that scans multiple samples over a long period of time by laterally relocating the sample stage. Hence, the relocation of the optics induces a statistical RoI offset and can introduce jitter as well as drift, which results in a misaligned RoI for each sample's time-lapse observation (stage drift). We introduce a robust approach to automatically align all frames within a time-lapse observation and compensate for frame drift. In this study, we present a sub-pixel precise alignment approach based on recurrent all-pairs field transforms (RAFT); a deep network architecture for optical flow. We show that the RAFT model pre-trained on the Sintel dataset performed with near perfect precision for registration tasks on a set of ten contextually unrelated time-lapse observations containing 250 frames each. Our approach is robust for elastically undistorted and translation displaced (x,y) microscopic time-lapse observations and was tested on multiple samples with varying cell density, obtained using different devices. The approach only performed well for registration and not for tracking of the individual image components like cells and contaminants. We provide an open-source command-line application that corrects for stage drift and jitter.</p>\",\"PeriodicalId\":37035,\"journal\":{\"name\":\"Journal of Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11355451/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/jimaging10080181\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jimaging10080181","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

在分析显微延时观察结果时,帧对准是直观了解细胞和组织形态及翻译动态的一项基本任务。在传统的单样品显微镜中,感兴趣区(RoI)是固定的,而多样品显微镜通常使用一台显微镜,通过横向移动样品台来长时间扫描多个样品。因此,光学器件的移动会引起统计上的 RoI 偏移,并可能引入抖动和漂移,从而导致每个样本的延时观测出现 RoI 错位(平台漂移)。我们引入了一种稳健的方法来自动对齐延时观测中的所有帧,并补偿帧漂移。在这项研究中,我们提出了一种基于递归全对场变换(RAFT)的亚像素精确对齐方法;RAFT 是一种用于光流的深度网络架构。我们的研究表明,在 Sintel 数据集上预先训练的 RAFT 模型在一组包含 250 个帧的 10 个上下文无关的延时观测数据的配准任务中表现出近乎完美的精度。我们的方法对于无弹性失真和平移位移(x,y)的显微延时观察结果具有鲁棒性,并在使用不同设备获得的具有不同细胞密度的多个样本上进行了测试。该方法仅在配准方面表现出色,而在跟踪细胞和污染物等单个图像组件方面却不尽如人意。我们提供了一个开源的命令行应用程序,可以校正平台漂移和抖动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fiduciary-Free Frame Alignment for Robust Time-Lapse Drift Correction Estimation in Multi-Sample Cell Microscopy.

When analyzing microscopic time-lapse observations, frame alignment is an essential task to visually understand the morphological and translation dynamics of cells and tissue. While in traditional single-sample microscopy, the region of interest (RoI) is fixed, multi-sample microscopy often uses a single microscope that scans multiple samples over a long period of time by laterally relocating the sample stage. Hence, the relocation of the optics induces a statistical RoI offset and can introduce jitter as well as drift, which results in a misaligned RoI for each sample's time-lapse observation (stage drift). We introduce a robust approach to automatically align all frames within a time-lapse observation and compensate for frame drift. In this study, we present a sub-pixel precise alignment approach based on recurrent all-pairs field transforms (RAFT); a deep network architecture for optical flow. We show that the RAFT model pre-trained on the Sintel dataset performed with near perfect precision for registration tasks on a set of ten contextually unrelated time-lapse observations containing 250 frames each. Our approach is robust for elastically undistorted and translation displaced (x,y) microscopic time-lapse observations and was tested on multiple samples with varying cell density, obtained using different devices. The approach only performed well for registration and not for tracking of the individual image components like cells and contaminants. We provide an open-source command-line application that corrects for stage drift and jitter.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Imaging
Journal of Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.90
自引率
6.20%
发文量
303
审稿时长
7 weeks
期刊最新文献
Efficient End-to-End Convolutional Architecture for Point-of-Gaze Estimation. Comparison of Visual and Quantra Software Mammographic Density Assessment According to BI-RADS® in 2D and 3D Images. A Multi-Task Model for Pulmonary Nodule Segmentation and Classification. Convolutional Neural Network-Machine Learning Model: Hybrid Model for Meningioma Tumour and Healthy Brain Classification. Historical Blurry Video-Based Face Recognition.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1