{"title":"通过力敏和温敏监测装置评估对头盔的依从性:病例对照研究","authors":"Francesca Cremonini, Ariyan Karami Shabankare, Daniela Guiducci, Luca Lombardo","doi":"10.3390/bioengineering11080789","DOIUrl":null,"url":null,"abstract":"<p><p>The aim was to objectively assess compliance in patients prescribed headgear and evaluate the impact of monitoring awareness, treatment duration, gender, and age on compliance levels. A total of 22 patients with Class II malocclusion wore the headgear integrated with the force and temperature sensitive Smartgear monitoring system (Smartgear, Swissorthodontics AG, Cham, Switzerland). Patients were instructed to wear the headgear for 13 h daily over a 3-month period. Randomly, 11 patients were informed that they monitored and 11 were not informed. Data were organized using Microsoft Excel and analyzed using R for statistical estimates, graphs, and hypothesis testing. Smartgear recorded an average daily compliance of 6.7 h. No statistically significant differences were found in cooperation between study group and control group over the 3 months of treatment, regardless of gender and age. However, there was slight greater cooperation in the first month than in the other months, and patients ≤10 years of age had almost 2 h more cooperation than their older counterparts. Moreover, the informed group exhibited an average of 1.1 more hours of cooperation per day than the uninformed group, which may carry clinical significance. This cooperation primarily occurred at night and was found to be statistically significant. Compliance among young patients typically remained lower than the prescribed level, regardless of their gender and psychological maturity. Although an awareness of monitoring does not seem to improve compliance, implementing such systems could still offer dentists a valuable means of obtaining objective information about their patients' adherence.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11351614/pdf/","citationCount":"0","resultStr":"{\"title\":\"Compliance with Headgear Evaluated by Force- and Temperature-Sensitive Monitoring Device: A Case-Control Study.\",\"authors\":\"Francesca Cremonini, Ariyan Karami Shabankare, Daniela Guiducci, Luca Lombardo\",\"doi\":\"10.3390/bioengineering11080789\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim was to objectively assess compliance in patients prescribed headgear and evaluate the impact of monitoring awareness, treatment duration, gender, and age on compliance levels. A total of 22 patients with Class II malocclusion wore the headgear integrated with the force and temperature sensitive Smartgear monitoring system (Smartgear, Swissorthodontics AG, Cham, Switzerland). Patients were instructed to wear the headgear for 13 h daily over a 3-month period. Randomly, 11 patients were informed that they monitored and 11 were not informed. Data were organized using Microsoft Excel and analyzed using R for statistical estimates, graphs, and hypothesis testing. Smartgear recorded an average daily compliance of 6.7 h. No statistically significant differences were found in cooperation between study group and control group over the 3 months of treatment, regardless of gender and age. However, there was slight greater cooperation in the first month than in the other months, and patients ≤10 years of age had almost 2 h more cooperation than their older counterparts. Moreover, the informed group exhibited an average of 1.1 more hours of cooperation per day than the uninformed group, which may carry clinical significance. This cooperation primarily occurred at night and was found to be statistically significant. Compliance among young patients typically remained lower than the prescribed level, regardless of their gender and psychological maturity. Although an awareness of monitoring does not seem to improve compliance, implementing such systems could still offer dentists a valuable means of obtaining objective information about their patients' adherence.</p>\",\"PeriodicalId\":8874,\"journal\":{\"name\":\"Bioengineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11351614/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bioengineering11080789\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11080789","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
摘要
研究的目的是客观评估头套患者的依从性,并评估监测意识、治疗时间、性别和年龄对依从性的影响。共有 22 名 II 类错牙合畸形患者佩戴了集成了力和温度敏感 Smartgear 监测系统(Smartgear,Swissorthodontics AG,瑞士 Cham)的头套筒。患者被要求在 3 个月内每天佩戴头套 13 小时。随机抽取的 11 名患者被告知他们接受了监测,11 名患者未被告知。数据使用 Microsoft Excel 整理,并使用 R 进行统计估算、图表和假设检验分析。在 3 个月的治疗过程中,研究组和对照组的合作程度在统计学上没有发现明显差异,性别和年龄也不例外。不过,第一个月的合作程度略高于其他月份,年龄小于 10 岁的患者比年龄较大的患者多出近 2 小时的合作时间。此外,知情组平均每天比不知情组多合作 1.1 小时,这可能具有临床意义。这种合作主要发生在夜间,在统计学上有显著意义。无论性别和心理成熟度如何,年轻患者的依从性通常仍低于规定水平。虽然监测意识似乎并不能提高患者的依从性,但实施这种系统仍能为牙医提供一种获取患者依从性客观信息的宝贵手段。
Compliance with Headgear Evaluated by Force- and Temperature-Sensitive Monitoring Device: A Case-Control Study.
The aim was to objectively assess compliance in patients prescribed headgear and evaluate the impact of monitoring awareness, treatment duration, gender, and age on compliance levels. A total of 22 patients with Class II malocclusion wore the headgear integrated with the force and temperature sensitive Smartgear monitoring system (Smartgear, Swissorthodontics AG, Cham, Switzerland). Patients were instructed to wear the headgear for 13 h daily over a 3-month period. Randomly, 11 patients were informed that they monitored and 11 were not informed. Data were organized using Microsoft Excel and analyzed using R for statistical estimates, graphs, and hypothesis testing. Smartgear recorded an average daily compliance of 6.7 h. No statistically significant differences were found in cooperation between study group and control group over the 3 months of treatment, regardless of gender and age. However, there was slight greater cooperation in the first month than in the other months, and patients ≤10 years of age had almost 2 h more cooperation than their older counterparts. Moreover, the informed group exhibited an average of 1.1 more hours of cooperation per day than the uninformed group, which may carry clinical significance. This cooperation primarily occurred at night and was found to be statistically significant. Compliance among young patients typically remained lower than the prescribed level, regardless of their gender and psychological maturity. Although an awareness of monitoring does not seem to improve compliance, implementing such systems could still offer dentists a valuable means of obtaining objective information about their patients' adherence.
期刊介绍:
Aims
Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal:
● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings.
● Manuscripts regarding research proposals and research ideas will be particularly welcomed.
● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds.
Scope
● Bionics and biological cybernetics: implantology; bio–abio interfaces
● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices
● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc.
● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology
● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering
● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation
● Translational bioengineering