{"title":"肌营养不良症患者使用躯干矫形器时的使用者视角和疲劳的心理生理学表现。","authors":"Ahmad Zahid Rao, Muhammad Danish Mujib, Muhammad Abul Hasan, Ahmad O Alokaily, Tayyaba Tahira, Saad Ahmed Qazi","doi":"10.3390/bioengineering11080780","DOIUrl":null,"url":null,"abstract":"<p><p>The chair-mounted passive trunk orthosis (CMPTO) is designed to enhance wheelchair safety for individuals with dystrophinopathy during their daily activities. Given the disease's progressive nature, it is crucial to ensure that assistive devices are carefully evaluated to prevent overexertion. This study aims to assess the CMPTO's user experience and its impact on fatigue-related psychophysiological measurements. We conducted electromyography (EMG) evaluations of four trunk muscles and assessed perceived exertion using the Borg CR-10 scale in 40 healthy subjects while they performed seated maximal reaching tasks with the CMPTO. Additionally, fifteen dystrophinopathy patients evaluated the CMPTO for usability with the System Usability Scale. Paired <i>t</i>-tests were employed to compare the median frequency (MDF) of EMG signals, the Wilcoxon signed-rank test for evaluating exertion, and the Mann-Whitney U test to compare the usability reported by patients to those of healthy subjects. The 4-way ANOVA revealed that MDF patterns were significantly influenced by task orientation for each muscle. The CMPTO did not cause a significant reduction in the MDF. Tasks requiring greater trunk rotation were perceived as more exhaustive. Patients reported acceptable usability with the CMPTO, with scores higher than those of healthy subjects. The CMPTO's usability was comprehensively evaluated in both healthy subjects and patients with dystrophinopathy. Our findings indicate that the CMPTO can be safely used by individuals with dystrophinopathy as an assistive device to improve seated comfort and functional abilities.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11351144/pdf/","citationCount":"0","resultStr":"{\"title\":\"User Perspectives and Psychophysiological Manifestations of Fatigue with Trunk Orthosis for Dystrophinopathy Patients.\",\"authors\":\"Ahmad Zahid Rao, Muhammad Danish Mujib, Muhammad Abul Hasan, Ahmad O Alokaily, Tayyaba Tahira, Saad Ahmed Qazi\",\"doi\":\"10.3390/bioengineering11080780\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The chair-mounted passive trunk orthosis (CMPTO) is designed to enhance wheelchair safety for individuals with dystrophinopathy during their daily activities. Given the disease's progressive nature, it is crucial to ensure that assistive devices are carefully evaluated to prevent overexertion. This study aims to assess the CMPTO's user experience and its impact on fatigue-related psychophysiological measurements. We conducted electromyography (EMG) evaluations of four trunk muscles and assessed perceived exertion using the Borg CR-10 scale in 40 healthy subjects while they performed seated maximal reaching tasks with the CMPTO. Additionally, fifteen dystrophinopathy patients evaluated the CMPTO for usability with the System Usability Scale. Paired <i>t</i>-tests were employed to compare the median frequency (MDF) of EMG signals, the Wilcoxon signed-rank test for evaluating exertion, and the Mann-Whitney U test to compare the usability reported by patients to those of healthy subjects. The 4-way ANOVA revealed that MDF patterns were significantly influenced by task orientation for each muscle. The CMPTO did not cause a significant reduction in the MDF. Tasks requiring greater trunk rotation were perceived as more exhaustive. Patients reported acceptable usability with the CMPTO, with scores higher than those of healthy subjects. The CMPTO's usability was comprehensively evaluated in both healthy subjects and patients with dystrophinopathy. Our findings indicate that the CMPTO can be safely used by individuals with dystrophinopathy as an assistive device to improve seated comfort and functional abilities.</p>\",\"PeriodicalId\":8874,\"journal\":{\"name\":\"Bioengineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11351144/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bioengineering11080780\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11080780","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
User Perspectives and Psychophysiological Manifestations of Fatigue with Trunk Orthosis for Dystrophinopathy Patients.
The chair-mounted passive trunk orthosis (CMPTO) is designed to enhance wheelchair safety for individuals with dystrophinopathy during their daily activities. Given the disease's progressive nature, it is crucial to ensure that assistive devices are carefully evaluated to prevent overexertion. This study aims to assess the CMPTO's user experience and its impact on fatigue-related psychophysiological measurements. We conducted electromyography (EMG) evaluations of four trunk muscles and assessed perceived exertion using the Borg CR-10 scale in 40 healthy subjects while they performed seated maximal reaching tasks with the CMPTO. Additionally, fifteen dystrophinopathy patients evaluated the CMPTO for usability with the System Usability Scale. Paired t-tests were employed to compare the median frequency (MDF) of EMG signals, the Wilcoxon signed-rank test for evaluating exertion, and the Mann-Whitney U test to compare the usability reported by patients to those of healthy subjects. The 4-way ANOVA revealed that MDF patterns were significantly influenced by task orientation for each muscle. The CMPTO did not cause a significant reduction in the MDF. Tasks requiring greater trunk rotation were perceived as more exhaustive. Patients reported acceptable usability with the CMPTO, with scores higher than those of healthy subjects. The CMPTO's usability was comprehensively evaluated in both healthy subjects and patients with dystrophinopathy. Our findings indicate that the CMPTO can be safely used by individuals with dystrophinopathy as an assistive device to improve seated comfort and functional abilities.
期刊介绍:
Aims
Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal:
● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings.
● Manuscripts regarding research proposals and research ideas will be particularly welcomed.
● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds.
Scope
● Bionics and biological cybernetics: implantology; bio–abio interfaces
● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices
● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc.
● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology
● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering
● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation
● Translational bioengineering