Ali Nozari, Maryam Pakniyat Jahromi, Farnaz Haji Abbas Oghli, Zahra Jowkar, Seyed Ahmadreza Hamidi
{"title":"通用粘合剂系统的不同应用模式对体积填充复合树脂与基牙釉质和牙本质粘结强度的影响","authors":"Ali Nozari, Maryam Pakniyat Jahromi, Farnaz Haji Abbas Oghli, Zahra Jowkar, Seyed Ahmadreza Hamidi","doi":"10.1002/cre2.947","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>The objective of this study was to assess how the application mode of a universal adhesive system affects the microshear bond strength (μSBS) of bulk-fill and conventional composite resins to enamel and dentin in primary teeth.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A total of 80 caries-free primary second molars were randomly assigned to eight experimental groups (<i>n</i> = 10) based on the bonding substrate (enamel or dentin), the application mode of the universal adhesive system (etch and rinse [E&R], or self-etch [SE]), and the type of composite resin used (bulk-fill or conventional). After bonding the composite resin to enamel or dentin, the μSBS of the bonded composite resins was measured.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The mean μSBS value of bulk-fill composite resin was significantly higher than that of conventional composite resin for both enamel and dentin substrates, regardless of the application mode (<i>p</i> < 0.001). An interaction effect between the bonding substrate and the application mode of the adhesive system was observed, indicating a significant relationship (<i>p</i> < 0.001). The highest μSBS values for primary teeth enamel were achieved using the E&R mode with bulk-fill composite resin, while for dentin specimens, the SE mode with bulk-fill composite resin yielded the highest μSBS values. The μSBS of the E&R group was significantly higher than that of the SE group for enamel specimens (<i>p</i> < 0.001), whereas the μSBS of the SE group was significantly higher than that of the E&R group for dentin specimens (<i>p</i> < 0.001).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Bulk-fill composite resin demonstrated higher μSBS in comparison to conventional composite resin. The universal adhesive system exhibited superior performance in the SE mode compared to the E&R mode on primary dentin. Pre-etching the enamel before the application of the universal adhesive enhanced the μSBS to primary teeth enamel, highlighting the importance of selectively acid etching the enamel of primary teeth.</p>\n </section>\n </div>","PeriodicalId":10203,"journal":{"name":"Clinical and Experimental Dental Research","volume":"10 4","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cre2.947","citationCount":"0","resultStr":"{\"title\":\"Influence of Different Application Modes of a Universal Adhesive System on the Bond Strength of Bulk-Fill Composite Resin to Enamel and Dentin in Primary Teeth\",\"authors\":\"Ali Nozari, Maryam Pakniyat Jahromi, Farnaz Haji Abbas Oghli, Zahra Jowkar, Seyed Ahmadreza Hamidi\",\"doi\":\"10.1002/cre2.947\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>The objective of this study was to assess how the application mode of a universal adhesive system affects the microshear bond strength (μSBS) of bulk-fill and conventional composite resins to enamel and dentin in primary teeth.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>A total of 80 caries-free primary second molars were randomly assigned to eight experimental groups (<i>n</i> = 10) based on the bonding substrate (enamel or dentin), the application mode of the universal adhesive system (etch and rinse [E&R], or self-etch [SE]), and the type of composite resin used (bulk-fill or conventional). After bonding the composite resin to enamel or dentin, the μSBS of the bonded composite resins was measured.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The mean μSBS value of bulk-fill composite resin was significantly higher than that of conventional composite resin for both enamel and dentin substrates, regardless of the application mode (<i>p</i> < 0.001). An interaction effect between the bonding substrate and the application mode of the adhesive system was observed, indicating a significant relationship (<i>p</i> < 0.001). The highest μSBS values for primary teeth enamel were achieved using the E&R mode with bulk-fill composite resin, while for dentin specimens, the SE mode with bulk-fill composite resin yielded the highest μSBS values. The μSBS of the E&R group was significantly higher than that of the SE group for enamel specimens (<i>p</i> < 0.001), whereas the μSBS of the SE group was significantly higher than that of the E&R group for dentin specimens (<i>p</i> < 0.001).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Bulk-fill composite resin demonstrated higher μSBS in comparison to conventional composite resin. The universal adhesive system exhibited superior performance in the SE mode compared to the E&R mode on primary dentin. Pre-etching the enamel before the application of the universal adhesive enhanced the μSBS to primary teeth enamel, highlighting the importance of selectively acid etching the enamel of primary teeth.</p>\\n </section>\\n </div>\",\"PeriodicalId\":10203,\"journal\":{\"name\":\"Clinical and Experimental Dental Research\",\"volume\":\"10 4\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cre2.947\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and Experimental Dental Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/cre2.947\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cre2.947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Influence of Different Application Modes of a Universal Adhesive System on the Bond Strength of Bulk-Fill Composite Resin to Enamel and Dentin in Primary Teeth
Objectives
The objective of this study was to assess how the application mode of a universal adhesive system affects the microshear bond strength (μSBS) of bulk-fill and conventional composite resins to enamel and dentin in primary teeth.
Methods
A total of 80 caries-free primary second molars were randomly assigned to eight experimental groups (n = 10) based on the bonding substrate (enamel or dentin), the application mode of the universal adhesive system (etch and rinse [E&R], or self-etch [SE]), and the type of composite resin used (bulk-fill or conventional). After bonding the composite resin to enamel or dentin, the μSBS of the bonded composite resins was measured.
Results
The mean μSBS value of bulk-fill composite resin was significantly higher than that of conventional composite resin for both enamel and dentin substrates, regardless of the application mode (p < 0.001). An interaction effect between the bonding substrate and the application mode of the adhesive system was observed, indicating a significant relationship (p < 0.001). The highest μSBS values for primary teeth enamel were achieved using the E&R mode with bulk-fill composite resin, while for dentin specimens, the SE mode with bulk-fill composite resin yielded the highest μSBS values. The μSBS of the E&R group was significantly higher than that of the SE group for enamel specimens (p < 0.001), whereas the μSBS of the SE group was significantly higher than that of the E&R group for dentin specimens (p < 0.001).
Conclusion
Bulk-fill composite resin demonstrated higher μSBS in comparison to conventional composite resin. The universal adhesive system exhibited superior performance in the SE mode compared to the E&R mode on primary dentin. Pre-etching the enamel before the application of the universal adhesive enhanced the μSBS to primary teeth enamel, highlighting the importance of selectively acid etching the enamel of primary teeth.
期刊介绍:
Clinical and Experimental Dental Research aims to provide open access peer-reviewed publications of high scientific quality representing original clinical, diagnostic or experimental work within all disciplines and fields of oral medicine and dentistry. The scope of Clinical and Experimental Dental Research comprises original research material on the anatomy, physiology and pathology of oro-facial, oro-pharyngeal and maxillofacial tissues, and functions and dysfunctions within the stomatognathic system, and the epidemiology, aetiology, prevention, diagnosis, prognosis and therapy of diseases and conditions that have an effect on the homeostasis of the mouth, jaws, and closely associated structures, as well as the healing and regeneration and the clinical aspects of replacement of hard and soft tissues with biomaterials, and the rehabilitation of stomatognathic functions. Studies that bring new knowledge on how to advance health on the individual or public health levels, including interactions between oral and general health and ill-health are welcome.