{"title":"用于超灵敏眼压监测的 LC 隐形眼镜传感器","authors":"Hongbin An, Xian Wang, Zhikang Liao, Liang Zhang, Hui Zhao, Yingyun Yang, Jizhou Song, Yinji Ma","doi":"10.1038/s41528-024-00341-z","DOIUrl":null,"url":null,"abstract":"Twenty-four hours continuous intraocular pressure (IOP) monitoring is beneficial for glaucoma care. Contact lens sensors using LC technology can achieve non-invasive continuous IOP measuring around the clock and are relatively simple in principle and structure, thus dominating the mainstream. Among them, stretchable inductive LC contact lens sensors constructed with liquid metal have advantages in signal quality as well as wearing comfort, but currently its sensitivity is slightly insufficient. Here, we propose an LC sensor that constructed with liquid metal to form the stretchable inductance and capacitance further. The capacitive plate and inductive coil can response to IOP changes simultaneously, thus able to enhance the sensitivity in principle. We modeled the sensing mechanism and conducted design, fabrication, as well as various tests. The device exhibits good characteristics, including reliability, good signal quality, etc. Especially, it has a threefold increase in sensitivity, exceeding the current state-of-the-art contact lens sensors.","PeriodicalId":48528,"journal":{"name":"npj Flexible Electronics","volume":null,"pages":null},"PeriodicalIF":12.3000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.nature.com/articles/s41528-024-00341-z.pdf","citationCount":"0","resultStr":"{\"title\":\"LC contact lens sensor for ultrasensitive intraocular pressure monitoring\",\"authors\":\"Hongbin An, Xian Wang, Zhikang Liao, Liang Zhang, Hui Zhao, Yingyun Yang, Jizhou Song, Yinji Ma\",\"doi\":\"10.1038/s41528-024-00341-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Twenty-four hours continuous intraocular pressure (IOP) monitoring is beneficial for glaucoma care. Contact lens sensors using LC technology can achieve non-invasive continuous IOP measuring around the clock and are relatively simple in principle and structure, thus dominating the mainstream. Among them, stretchable inductive LC contact lens sensors constructed with liquid metal have advantages in signal quality as well as wearing comfort, but currently its sensitivity is slightly insufficient. Here, we propose an LC sensor that constructed with liquid metal to form the stretchable inductance and capacitance further. The capacitive plate and inductive coil can response to IOP changes simultaneously, thus able to enhance the sensitivity in principle. We modeled the sensing mechanism and conducted design, fabrication, as well as various tests. The device exhibits good characteristics, including reliability, good signal quality, etc. Especially, it has a threefold increase in sensitivity, exceeding the current state-of-the-art contact lens sensors.\",\"PeriodicalId\":48528,\"journal\":{\"name\":\"npj Flexible Electronics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":12.3000,\"publicationDate\":\"2024-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.nature.com/articles/s41528-024-00341-z.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"npj Flexible Electronics\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://www.nature.com/articles/s41528-024-00341-z\",\"RegionNum\":1,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"npj Flexible Electronics","FirstCategoryId":"88","ListUrlMain":"https://www.nature.com/articles/s41528-024-00341-z","RegionNum":1,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

24 小时连续眼压监测有利于青光眼的治疗。采用 LC 技术的隐形眼镜传感器可实现全天候无创连续眼压测量,且原理和结构相对简单,因此占据主流。其中,采用液态金属构造的可拉伸电感式 LC 隐形眼镜传感器在信号质量和佩戴舒适度方面具有优势,但目前其灵敏度略显不足。在此,我们提出了一种利用液态金属进一步形成可拉伸电感和电容的 LC 传感器。电容板和电感线圈可同时对眼压变化做出响应,从而在原理上提高了灵敏度。我们建立了传感机制模型,并进行了设计、制造和各种测试。该装置表现出良好的特性,包括可靠性、良好的信号质量等。特别是,它的灵敏度提高了三倍,超过了目前最先进的隐形眼镜传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
LC contact lens sensor for ultrasensitive intraocular pressure monitoring
Twenty-four hours continuous intraocular pressure (IOP) monitoring is beneficial for glaucoma care. Contact lens sensors using LC technology can achieve non-invasive continuous IOP measuring around the clock and are relatively simple in principle and structure, thus dominating the mainstream. Among them, stretchable inductive LC contact lens sensors constructed with liquid metal have advantages in signal quality as well as wearing comfort, but currently its sensitivity is slightly insufficient. Here, we propose an LC sensor that constructed with liquid metal to form the stretchable inductance and capacitance further. The capacitive plate and inductive coil can response to IOP changes simultaneously, thus able to enhance the sensitivity in principle. We modeled the sensing mechanism and conducted design, fabrication, as well as various tests. The device exhibits good characteristics, including reliability, good signal quality, etc. Especially, it has a threefold increase in sensitivity, exceeding the current state-of-the-art contact lens sensors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
17.10
自引率
4.80%
发文量
91
审稿时长
6 weeks
期刊介绍: npj Flexible Electronics is an online-only and open access journal, which publishes high-quality papers related to flexible electronic systems, including plastic electronics and emerging materials, new device design and fabrication technologies, and applications.
期刊最新文献
Interplay between strain and charge in Cu(In,Ga)Se2 flexible photovoltaics Creating highly efficient stretchable OLEDs with nanowavy structures for angle-independent narrow band emission Strong and high-conductivity hydrogels with all-polymer nanofibrous networks for applications as high-capacitance flexible electrodes Electrically tunable infrared optics enabled by flexible ion-permeable conducting polymer-cellulose paper Conformal printed electronics on flexible substrates and inflatable catheters using lathe-based aerosol jet printing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1