人类上颌后牙种植体骨增生钻孔的初期稳定性:系统综述。

IF 2.7 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Dental and Medical Problems Pub Date : 2024-07-01 DOI:10.17219/dmp/163136
Alejandro Fereño-Cáceres, Rómulo Vélez-Astudillo, Wilson Bravo-Torres, Daniela Astudillo-Rubio, Jacinto Alvarado-Cordero
{"title":"人类上颌后牙种植体骨增生钻孔的初期稳定性:系统综述。","authors":"Alejandro Fereño-Cáceres, Rómulo Vélez-Astudillo, Wilson Bravo-Torres, Daniela Astudillo-Rubio, Jacinto Alvarado-Cordero","doi":"10.17219/dmp/163136","DOIUrl":null,"url":null,"abstract":"<p><p>Currently, a new non-subtractive drilling technique, called osseodensification (OD), has been developed. It involves using specially designed drills with large negative cutting angles that rotate counterclockwise, causing expansion through plastic bone deformation, thus compacting the autologous bone to the osteotomy walls, which improves the primary stability of the implant.The present systematic review aimed to determine whether the OD technique can increase the primary stability of dental implants in the posterior maxilla region as compared to the conventional drilling (CD) technique.Five databases were searched up to June 30, 2022. The inclusion criteria embraced observational clinical studies, randomized and non-randomized controlled trials, human studies in vivo, comparing OD and CD, with the measurement of the primary stability of implants in the posterior maxilla region by means of the implant stability quotient (ISQ). The tools used to assess the risk of bias were RoB 2 and the NewcastleOttawa Scale (NOS).Seven articles met the inclusion criteria, with 4 classified as having a low risk of bias and 3 with a moderate risk of bias. The OD technique consistently demonstrated an average ISQ value of 73 KHz across all studies, whereas CD yielded an average value of 58.49 kHz (p < 0.001 for 5 articles).It can be concluded that in comparison with CD, OD improves primary stability at baseline in low-density bone, such as the maxilla.</p>","PeriodicalId":11191,"journal":{"name":"Dental and Medical Problems","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Primary stability with osseodensification drilling of dental implants in the posterior maxilla region in humans: A systematic review.\",\"authors\":\"Alejandro Fereño-Cáceres, Rómulo Vélez-Astudillo, Wilson Bravo-Torres, Daniela Astudillo-Rubio, Jacinto Alvarado-Cordero\",\"doi\":\"10.17219/dmp/163136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Currently, a new non-subtractive drilling technique, called osseodensification (OD), has been developed. It involves using specially designed drills with large negative cutting angles that rotate counterclockwise, causing expansion through plastic bone deformation, thus compacting the autologous bone to the osteotomy walls, which improves the primary stability of the implant.The present systematic review aimed to determine whether the OD technique can increase the primary stability of dental implants in the posterior maxilla region as compared to the conventional drilling (CD) technique.Five databases were searched up to June 30, 2022. The inclusion criteria embraced observational clinical studies, randomized and non-randomized controlled trials, human studies in vivo, comparing OD and CD, with the measurement of the primary stability of implants in the posterior maxilla region by means of the implant stability quotient (ISQ). The tools used to assess the risk of bias were RoB 2 and the NewcastleOttawa Scale (NOS).Seven articles met the inclusion criteria, with 4 classified as having a low risk of bias and 3 with a moderate risk of bias. The OD technique consistently demonstrated an average ISQ value of 73 KHz across all studies, whereas CD yielded an average value of 58.49 kHz (p < 0.001 for 5 articles).It can be concluded that in comparison with CD, OD improves primary stability at baseline in low-density bone, such as the maxilla.</p>\",\"PeriodicalId\":11191,\"journal\":{\"name\":\"Dental and Medical Problems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental and Medical Problems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17219/dmp/163136\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental and Medical Problems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17219/dmp/163136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目前,已开发出一种新的非屈曲钻孔技术,称为骨增量(OD)。本系统性综述旨在确定与传统钻孔(CD)技术相比,OD 技术是否能增加上颌后牙种植体的主要稳定性。纳入标准包括观察性临床研究、随机和非随机对照试验、活体人体研究、OD 和 CD 的比较研究,并通过种植体稳定性商数(ISQ)测量上颌后部种植体的主要稳定性。用于评估偏倚风险的工具是 RoB 2 和纽卡斯尔-渥太华量表(Newcastle-Ottawa Scale,NOS)。在所有研究中,OD技术的平均ISQ值始终为73千赫,而CD技术的平均值为58.49千赫(5篇文章的P<0.001)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Primary stability with osseodensification drilling of dental implants in the posterior maxilla region in humans: A systematic review.

Currently, a new non-subtractive drilling technique, called osseodensification (OD), has been developed. It involves using specially designed drills with large negative cutting angles that rotate counterclockwise, causing expansion through plastic bone deformation, thus compacting the autologous bone to the osteotomy walls, which improves the primary stability of the implant.The present systematic review aimed to determine whether the OD technique can increase the primary stability of dental implants in the posterior maxilla region as compared to the conventional drilling (CD) technique.Five databases were searched up to June 30, 2022. The inclusion criteria embraced observational clinical studies, randomized and non-randomized controlled trials, human studies in vivo, comparing OD and CD, with the measurement of the primary stability of implants in the posterior maxilla region by means of the implant stability quotient (ISQ). The tools used to assess the risk of bias were RoB 2 and the NewcastleOttawa Scale (NOS).Seven articles met the inclusion criteria, with 4 classified as having a low risk of bias and 3 with a moderate risk of bias. The OD technique consistently demonstrated an average ISQ value of 73 KHz across all studies, whereas CD yielded an average value of 58.49 kHz (p < 0.001 for 5 articles).It can be concluded that in comparison with CD, OD improves primary stability at baseline in low-density bone, such as the maxilla.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.00
自引率
3.80%
发文量
58
审稿时长
53 weeks
期刊最新文献
Most common congenital syndromes with facial asymmetry: A narrative review. Self-assessment skills of undergraduate students in operative dentistry: Preclinical performance and gender. Optical properties of advanced lithium disilicate. Studies on the content of toxic metals in teeth: A narrative review of literature. Kinesio Taping as an alternative therapy for limited mandibular mobility with pain in female patients with temporomandibular disorders: A randomized controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1