常用移动眼科应用的视力评估工具在测量五个视力评估参数方面的准确性。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-09-02 DOI:10.1038/s41433-024-03315-7
Austin Raney, Savannah Cottom, Jonathan Huff, Tavis Phan, Austin LaGrow, Christian Leal, Justin D Dvorak, Kamran M Riaz
{"title":"常用移动眼科应用的视力评估工具在测量五个视力评估参数方面的准确性。","authors":"Austin Raney, Savannah Cottom, Jonathan Huff, Tavis Phan, Austin LaGrow, Christian Leal, Justin D Dvorak, Kamran M Riaz","doi":"10.1038/s41433-024-03315-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/objectives: </strong>The use of mobile ophthalmology applications (MOA) is increasing, but many of these tools have not been validated. This study was performed to assess the accuracy of a popular MOA, Eye Handbook, in measuring five commonly-tested vision assessment parameters (distance visual acuity (DVA), near visual acuity (NVA), colour vision testing (CVT), contrast sensitivity (CS), and pupillary distance (PD)) was compared with traditional vision assessment methods (TVAM) [i.e. Snellen chart, Rosenbaum near card, Ishihara, Pelli Robson test, etc.] performed in the eye clinic setting.</p><p><strong>Subjects/methods: </strong>Prospective crossover clinical trial of 129 patients meeting inclusion criteria.</p><p><strong>Results: </strong>Participants averaged significantly better DVA (p = 0.0008), NVA (p < 0.0001), and CVT (p = 0.0105) in the MOA than the TVAM, but all three MOA assessments were predictive of the TVAM values. CS was significantly better with the MOA (p < 0.0001). Linear regression and Spearman correlation tests were applied to assess the effect of CS on NVA, which showed no clear relationship between the difference in NVA and the difference in CS. PD using the two methods was in agreement with no significant difference (p = 0.2889).</p><p><strong>Conclusion: </strong>The studied MOA offers an effective means of measuring four common vision parameters: DVA, NVA, CVT, and PD. The MOA can potentially be used by eye care providers, health care providers, and patients, both as a screening tool with correction factor and to monitor ocular pathologies. Atypical MOA measurements should prompt testing in the clinic with formal TVAMs.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of a commonly used mobile ophthalmology application's vision assessment tools in measuring five vision assessment parameters.\",\"authors\":\"Austin Raney, Savannah Cottom, Jonathan Huff, Tavis Phan, Austin LaGrow, Christian Leal, Justin D Dvorak, Kamran M Riaz\",\"doi\":\"10.1038/s41433-024-03315-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/objectives: </strong>The use of mobile ophthalmology applications (MOA) is increasing, but many of these tools have not been validated. This study was performed to assess the accuracy of a popular MOA, Eye Handbook, in measuring five commonly-tested vision assessment parameters (distance visual acuity (DVA), near visual acuity (NVA), colour vision testing (CVT), contrast sensitivity (CS), and pupillary distance (PD)) was compared with traditional vision assessment methods (TVAM) [i.e. Snellen chart, Rosenbaum near card, Ishihara, Pelli Robson test, etc.] performed in the eye clinic setting.</p><p><strong>Subjects/methods: </strong>Prospective crossover clinical trial of 129 patients meeting inclusion criteria.</p><p><strong>Results: </strong>Participants averaged significantly better DVA (p = 0.0008), NVA (p < 0.0001), and CVT (p = 0.0105) in the MOA than the TVAM, but all three MOA assessments were predictive of the TVAM values. CS was significantly better with the MOA (p < 0.0001). Linear regression and Spearman correlation tests were applied to assess the effect of CS on NVA, which showed no clear relationship between the difference in NVA and the difference in CS. PD using the two methods was in agreement with no significant difference (p = 0.2889).</p><p><strong>Conclusion: </strong>The studied MOA offers an effective means of measuring four common vision parameters: DVA, NVA, CVT, and PD. The MOA can potentially be used by eye care providers, health care providers, and patients, both as a screening tool with correction factor and to monitor ocular pathologies. Atypical MOA measurements should prompt testing in the clinic with formal TVAMs.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-09-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1038/s41433-024-03315-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41433-024-03315-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:移动眼科应用程序(MOA)的使用日益增多,但其中许多工具尚未经过验证。本研究旨在评估一款流行的移动眼科应用软件《Eye Handbook》在测量五种常用视力评估参数(远视力(DVA)、近视力(NVA)、色觉测试(CVT)、对比敏感度(CS)和瞳孔距离(PD))方面的准确性,并将其与在眼科诊所环境中进行的传统视力评估方法(TVAM)[即斯奈伦视力表、罗森鲍姆近视力表、石原视力表、佩里-罗布森测试等]进行比较:对符合纳入标准的 129 名患者进行前瞻性交叉临床试验:结果:参与者的 DVA(P = 0.0008)、NVA(P 结论:所研究的 MOA 为患者提供了有效的治疗手段:所研究的 MOA 是测量四种常见视力参数的有效方法:DVA、NVA、CVT 和 PD。眼科保健提供者、医疗保健提供者和患者可将 MOA 用作具有校正因子的筛查工具,也可用于监测眼部病变。如果 MOA 测量结果不正常,应立即在临床上使用正规的 TVAM 进行检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accuracy of a commonly used mobile ophthalmology application's vision assessment tools in measuring five vision assessment parameters.

Background/objectives: The use of mobile ophthalmology applications (MOA) is increasing, but many of these tools have not been validated. This study was performed to assess the accuracy of a popular MOA, Eye Handbook, in measuring five commonly-tested vision assessment parameters (distance visual acuity (DVA), near visual acuity (NVA), colour vision testing (CVT), contrast sensitivity (CS), and pupillary distance (PD)) was compared with traditional vision assessment methods (TVAM) [i.e. Snellen chart, Rosenbaum near card, Ishihara, Pelli Robson test, etc.] performed in the eye clinic setting.

Subjects/methods: Prospective crossover clinical trial of 129 patients meeting inclusion criteria.

Results: Participants averaged significantly better DVA (p = 0.0008), NVA (p < 0.0001), and CVT (p = 0.0105) in the MOA than the TVAM, but all three MOA assessments were predictive of the TVAM values. CS was significantly better with the MOA (p < 0.0001). Linear regression and Spearman correlation tests were applied to assess the effect of CS on NVA, which showed no clear relationship between the difference in NVA and the difference in CS. PD using the two methods was in agreement with no significant difference (p = 0.2889).

Conclusion: The studied MOA offers an effective means of measuring four common vision parameters: DVA, NVA, CVT, and PD. The MOA can potentially be used by eye care providers, health care providers, and patients, both as a screening tool with correction factor and to monitor ocular pathologies. Atypical MOA measurements should prompt testing in the clinic with formal TVAMs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1