利用聚乙二醇进行表面改性,提高无阻断剂荧光极化测定的灵敏度

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analyst Pub Date : 2024-09-03 DOI:10.1039/D4AN00569D
Hao Liu, Mao Fukuyama, Yu Ogura, Motohiro Kasuya, Sho Onose, Ayuko Imai, Koji Shigemura, Manabu Tokeshi and Akihide Hibara
{"title":"利用聚乙二醇进行表面改性,提高无阻断剂荧光极化测定的灵敏度","authors":"Hao Liu, Mao Fukuyama, Yu Ogura, Motohiro Kasuya, Sho Onose, Ayuko Imai, Koji Shigemura, Manabu Tokeshi and Akihide Hibara","doi":"10.1039/D4AN00569D","DOIUrl":null,"url":null,"abstract":"<p >Fluorescence polarization (FP) assays are widely used to quantify biomolecules, and their combination with microfluidic devices has the potential for application in onsite analysis. However, the hydrophobic surface of polydimethylsiloxane (PDMS)-based microfluidic devices and the amphiphilicity of the blocking agents can cause the nonspecific adsorption of biomolecules, which in turn reduces the sensitivity of the FP assay. To address this, we demonstrated an FP assay with improved sensitivity in microfluidic devices using a polyethylene glycol-based surface modification to avoid the use of blocking agents. We evaluated the effectiveness of the modification in inhibiting nonspecific protein adsorption and demonstrated the improved sensitivity of the FP immunoassay (FPIA). Our study addressed the lack of sensitivity of FP assays in microfluidic devices, particularly for the quantification of low-abundance analytes.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":" 20","pages":" 5139-5144"},"PeriodicalIF":3.6000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensitivity-improved blocking agent-free fluorescence polarization assay through surface modification using polyethylene glycol†\",\"authors\":\"Hao Liu, Mao Fukuyama, Yu Ogura, Motohiro Kasuya, Sho Onose, Ayuko Imai, Koji Shigemura, Manabu Tokeshi and Akihide Hibara\",\"doi\":\"10.1039/D4AN00569D\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Fluorescence polarization (FP) assays are widely used to quantify biomolecules, and their combination with microfluidic devices has the potential for application in onsite analysis. However, the hydrophobic surface of polydimethylsiloxane (PDMS)-based microfluidic devices and the amphiphilicity of the blocking agents can cause the nonspecific adsorption of biomolecules, which in turn reduces the sensitivity of the FP assay. To address this, we demonstrated an FP assay with improved sensitivity in microfluidic devices using a polyethylene glycol-based surface modification to avoid the use of blocking agents. We evaluated the effectiveness of the modification in inhibiting nonspecific protein adsorption and demonstrated the improved sensitivity of the FP immunoassay (FPIA). Our study addressed the lack of sensitivity of FP assays in microfluidic devices, particularly for the quantification of low-abundance analytes.</p>\",\"PeriodicalId\":63,\"journal\":{\"name\":\"Analyst\",\"volume\":\" 20\",\"pages\":\" 5139-5144\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analyst\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/an/d4an00569d\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/an/d4an00569d","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

荧光偏振(FP)检测法被广泛用于定量检测生物大分子,其与微流控装置的结合有望应用于现场分析。然而,基于聚二甲基硅氧烷(PDMS)的微流体设备的疏水性表面和阻断剂的两亲性会导致生物分子的非特异性吸附,进而降低 FP 检测的灵敏度。为了解决这个问题,我们利用一种基于聚乙二醇的表面改性剂,避免了阻断剂的使用,在微流控装置中演示了一种灵敏度更高的 FP 检测方法。我们评估了改性在抑制非特异性蛋白质吸附方面的效果,并证明了 FP 免疫测定 (FPIA) 灵敏度的提高。我们的研究解决了微流控装置中 FP 检测灵敏度不足的问题,尤其是在低丰度分析物的定量方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Sensitivity-improved blocking agent-free fluorescence polarization assay through surface modification using polyethylene glycol†

Fluorescence polarization (FP) assays are widely used to quantify biomolecules, and their combination with microfluidic devices has the potential for application in onsite analysis. However, the hydrophobic surface of polydimethylsiloxane (PDMS)-based microfluidic devices and the amphiphilicity of the blocking agents can cause the nonspecific adsorption of biomolecules, which in turn reduces the sensitivity of the FP assay. To address this, we demonstrated an FP assay with improved sensitivity in microfluidic devices using a polyethylene glycol-based surface modification to avoid the use of blocking agents. We evaluated the effectiveness of the modification in inhibiting nonspecific protein adsorption and demonstrated the improved sensitivity of the FP immunoassay (FPIA). Our study addressed the lack of sensitivity of FP assays in microfluidic devices, particularly for the quantification of low-abundance analytes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
期刊最新文献
An amplification-free digital droplet assay for influenza A viral RNA based on CRISPR/Cas13a. Evaluating sample normalization methods for MS-based multi-omics and the application to a neurodegenerative mouse model Correction: Infrared spectromicroscopy of biochemistry in functional single cells Shifted-excitation Raman difference spectroscopy and charge-shifting detection coupled with spatially offset Raman spectroscopy for heritage science Dual Proximity Ligation Mediated Chain Extension and Displacement Assisted Signal Cycles for Sensitive and Accurate Methicillin-Resistant Staphylococcus Aureus (MRSA) Detection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1