在充气前使用手术止血带会增加上肢静脉压力;可能会导致失血量增加和能见度降低。

Ross Condell, Dhruv Kapoor, Alexander Price, David O'Briain
{"title":"在充气前使用手术止血带会增加上肢静脉压力;可能会导致失血量增加和能见度降低。","authors":"Ross Condell, Dhruv Kapoor, Alexander Price, David O'Briain","doi":"10.1016/j.surge.2024.08.015","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Tourniquets are commonly used in extremity surgery to help provide a bloodless operative field to improve visibility and reduce length of procedures. With the development of WALANT (wide awake, local anaesthetic, no tourniquet) techniques, many surgeons undertake surgery without tourniquet inflation. The correct technique of pneumatic tourniquet application is poorly understood by healthcare staff. The application of a tight tourniquet when applied for optional use or use for only a portion of a procedure, rather than for inflation throughout can cause venous engorgement of an extremity leading to increased blood loss and reduced operative field visualisation thereby discouraging surgeons from persevering with WALANT strategies.</p><p><strong>Aim: </strong>To determine the effect of tourniquet application tension on limb volume prior to skin incision.</p><p><strong>Methods: </strong>30 volunteers had the volume of their non-dominant forearm measured post-inflation of a surgical tourniquet using two different application techniques. Tight application was defined as the tourniquet fastened using a dynamometer to a tension of 100 N. Loose application was defined as the tourniquet fastened using a dynamometer to a tension of 50 N. The tourniquet was then inflated to 200 mmHg after both application techniques. Exsanguination was performed by elevation of the arm for 1 min prior to tourniquet inflation. At 5 min the forearm volume was measured using a volume displacement technique.</p><p><strong>Results: </strong>93 % of participants (28/30) had a higher volume of water displaced when the tourniquet was applied tightly. The mean difference between the loose and tight applications was 30.06 mls.</p><p><strong>Conclusion: </strong>The increase in volume in tightly applied tourniquets is believed to result from increased intravascular volume. This increase in blood volume can lead to increased intra-operative blood loss and poor intra-operative visualisation when operating without tourniquet inflation. Loose application of the tourniquet pre-inflation appears to prevent sequestration of venous blood in the limb, therefore decreasing operative blood loss and improving view for operating.</p><p><strong>Level of evidence: </strong>Level 1; Symptom Prevalence Study.</p>","PeriodicalId":49463,"journal":{"name":"Surgeon-Journal of the Royal Colleges of Surgeons of Edinburgh and Ireland","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tight application of a surgical tourniquet prior to inflation increases venous pressure in the upper limb; Potentially resulting in increased blood loss and poorer visibility.\",\"authors\":\"Ross Condell, Dhruv Kapoor, Alexander Price, David O'Briain\",\"doi\":\"10.1016/j.surge.2024.08.015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Tourniquets are commonly used in extremity surgery to help provide a bloodless operative field to improve visibility and reduce length of procedures. With the development of WALANT (wide awake, local anaesthetic, no tourniquet) techniques, many surgeons undertake surgery without tourniquet inflation. The correct technique of pneumatic tourniquet application is poorly understood by healthcare staff. The application of a tight tourniquet when applied for optional use or use for only a portion of a procedure, rather than for inflation throughout can cause venous engorgement of an extremity leading to increased blood loss and reduced operative field visualisation thereby discouraging surgeons from persevering with WALANT strategies.</p><p><strong>Aim: </strong>To determine the effect of tourniquet application tension on limb volume prior to skin incision.</p><p><strong>Methods: </strong>30 volunteers had the volume of their non-dominant forearm measured post-inflation of a surgical tourniquet using two different application techniques. Tight application was defined as the tourniquet fastened using a dynamometer to a tension of 100 N. Loose application was defined as the tourniquet fastened using a dynamometer to a tension of 50 N. The tourniquet was then inflated to 200 mmHg after both application techniques. Exsanguination was performed by elevation of the arm for 1 min prior to tourniquet inflation. At 5 min the forearm volume was measured using a volume displacement technique.</p><p><strong>Results: </strong>93 % of participants (28/30) had a higher volume of water displaced when the tourniquet was applied tightly. The mean difference between the loose and tight applications was 30.06 mls.</p><p><strong>Conclusion: </strong>The increase in volume in tightly applied tourniquets is believed to result from increased intravascular volume. This increase in blood volume can lead to increased intra-operative blood loss and poor intra-operative visualisation when operating without tourniquet inflation. Loose application of the tourniquet pre-inflation appears to prevent sequestration of venous blood in the limb, therefore decreasing operative blood loss and improving view for operating.</p><p><strong>Level of evidence: </strong>Level 1; Symptom Prevalence Study.</p>\",\"PeriodicalId\":49463,\"journal\":{\"name\":\"Surgeon-Journal of the Royal Colleges of Surgeons of Edinburgh and Ireland\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgeon-Journal of the Royal Colleges of Surgeons of Edinburgh and Ireland\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.surge.2024.08.015\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgeon-Journal of the Royal Colleges of Surgeons of Edinburgh and Ireland","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.surge.2024.08.015","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景:止血带常用于四肢手术,有助于提供一个无血的手术区域,从而提高手术的可视性并缩短手术时间。随着 WALANT(清醒、局部麻醉、不使用止血带)技术的发展,许多外科医生在进行手术时都不使用止血带。医护人员对正确使用气动止血带的技术了解甚少。目的:确定止血带使用张力对皮肤切口前肢体体积的影响。方法:30 名志愿者在使用两种不同的止血带使用技术进行手术止血带充气后测量其非主位前臂的体积。紧绑止血带的定义是使用测力计将止血带绑至 100 牛顿的张力;松绑止血带的定义是使用测力计将止血带绑至 50 牛顿的张力。在止血带充气前抬高手臂 1 分钟进行止血。5 分钟后,使用体积位移技术测量前臂体积:结果:93%的参与者(28/30)在止血带使用过紧时会有更大的水量排出。结果:93% 的参与者(28/30)在止血带扎紧时流出的水量较多,松紧止血带之间的平均差异为 30.06 毫升:结论:紧扎止血带时体积的增加被认为是血管内容量增加的结果。这种血容量的增加会导致术中失血量增加,以及在不使用止血带充气的情况下进行手术时术中视野不佳。松绑止血带似乎可以防止静脉血淤积在肢体中,从而减少手术失血量并改善手术视野:证据级别:1 级;症状流行研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Tight application of a surgical tourniquet prior to inflation increases venous pressure in the upper limb; Potentially resulting in increased blood loss and poorer visibility.

Background: Tourniquets are commonly used in extremity surgery to help provide a bloodless operative field to improve visibility and reduce length of procedures. With the development of WALANT (wide awake, local anaesthetic, no tourniquet) techniques, many surgeons undertake surgery without tourniquet inflation. The correct technique of pneumatic tourniquet application is poorly understood by healthcare staff. The application of a tight tourniquet when applied for optional use or use for only a portion of a procedure, rather than for inflation throughout can cause venous engorgement of an extremity leading to increased blood loss and reduced operative field visualisation thereby discouraging surgeons from persevering with WALANT strategies.

Aim: To determine the effect of tourniquet application tension on limb volume prior to skin incision.

Methods: 30 volunteers had the volume of their non-dominant forearm measured post-inflation of a surgical tourniquet using two different application techniques. Tight application was defined as the tourniquet fastened using a dynamometer to a tension of 100 N. Loose application was defined as the tourniquet fastened using a dynamometer to a tension of 50 N. The tourniquet was then inflated to 200 mmHg after both application techniques. Exsanguination was performed by elevation of the arm for 1 min prior to tourniquet inflation. At 5 min the forearm volume was measured using a volume displacement technique.

Results: 93 % of participants (28/30) had a higher volume of water displaced when the tourniquet was applied tightly. The mean difference between the loose and tight applications was 30.06 mls.

Conclusion: The increase in volume in tightly applied tourniquets is believed to result from increased intravascular volume. This increase in blood volume can lead to increased intra-operative blood loss and poor intra-operative visualisation when operating without tourniquet inflation. Loose application of the tourniquet pre-inflation appears to prevent sequestration of venous blood in the limb, therefore decreasing operative blood loss and improving view for operating.

Level of evidence: Level 1; Symptom Prevalence Study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.40
自引率
0.00%
发文量
158
审稿时长
6-12 weeks
期刊介绍: Since its establishment in 2003, The Surgeon has established itself as one of the leading multidisciplinary surgical titles, both in print and online. The Surgeon is published for the worldwide surgical and dental communities. The goal of the Journal is to achieve wider national and international recognition, through a commitment to excellence in original research. In addition, both Colleges see the Journal as an important educational service, and consequently there is a particular focus on post-graduate development. Much of our educational role will continue to be achieved through publishing expanded review articles by leaders in their field. Articles in related areas to surgery and dentistry, such as healthcare management and education, are also welcomed. We aim to educate, entertain, give insight into new surgical techniques and technology, and provide a forum for debate and discussion.
期刊最新文献
Comment on, "2-methoxyestradiol sensitizes tamoxifen-resistant MCF-7 breast cancer cells via downregulating HIF-1α". The effect of forced-air warming blanket position during spinal surgery on patients' intra-operative body temperature. List of editors Tight application of a surgical tourniquet prior to inflation increases venous pressure in the upper limb; Potentially resulting in increased blood loss and poorer visibility. Surgical procedures performed by non-medical practitioners, reviewing the era of the barber-surgeon.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1