求助PDF
{"title":"对复方新诺明非即刻过敏的斑贴试验:有用吗?","authors":"João Nuno Soares, João Pedro Teixeira, Ana Carolina Figueiredo, André Castro Pinho, Margarida Gonçalo","doi":"10.1111/cod.14692","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Existing literature has questioned the sensitivity of patch testing (PT) with cotrimoxazole (CTX) in the study of drug hypersensitivity.</p>\n </section>\n \n <section>\n \n <h3> Objectives</h3>\n \n <p>Assess the sensitivity of PT with CTX in non-immediate cutaneous adverse drug reactions (CADR).</p>\n </section>\n \n <section>\n \n <h3> Patients/Materials/Methods</h3>\n \n <p>Retrospective analysis (2000–2022) of PT with an antibiotic series including CTX 10% pet (Chemotechnique Diagnostics©) performed according to ESCD guidelines in patients with suspected non-immediate CADR reactions to CTX. Some patients were additionally tested with in-house preparations of CTX from Bactrim DS® tablets at 10% in pet or water and trimethoprim 10% pet (Laboratórios Edol©).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Sixty-four patients (48F/16M; mean age 47 ± 18) were included, mostly with maculopapular exanthema (51, 80%). Notably, CTX was sole suspect in 24 patients. There was no positive reaction to CTX at 10% from Chemotechnique or Bactrim DS® tablets prepared at 10% pet for patch testing. One patient reacted exclusively to trimethoprim with 1+ reaction. Two patients had a faint reaction (1+) only with the powder of Bactrim DS® tablets in water at D2, but as the reactions faded completely in 24 or 48 h, they were interpreted as irritant non-specific reactions.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>These findings suggest that patch testing may lack sufficient sensitivity to diagnose CTX-induced non-immediate CADR. Therefore, clinicians should be cautious interpreting CTX patch test results.</p>\n </section>\n </div>","PeriodicalId":4,"journal":{"name":"ACS Applied Energy Materials","volume":null,"pages":null},"PeriodicalIF":5.4000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Patch testing in non-immediate hypersensitivity to cotrimoxazole: Is it useful?\",\"authors\":\"João Nuno Soares, João Pedro Teixeira, Ana Carolina Figueiredo, André Castro Pinho, Margarida Gonçalo\",\"doi\":\"10.1111/cod.14692\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Existing literature has questioned the sensitivity of patch testing (PT) with cotrimoxazole (CTX) in the study of drug hypersensitivity.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>Assess the sensitivity of PT with CTX in non-immediate cutaneous adverse drug reactions (CADR).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Patients/Materials/Methods</h3>\\n \\n <p>Retrospective analysis (2000–2022) of PT with an antibiotic series including CTX 10% pet (Chemotechnique Diagnostics©) performed according to ESCD guidelines in patients with suspected non-immediate CADR reactions to CTX. Some patients were additionally tested with in-house preparations of CTX from Bactrim DS® tablets at 10% in pet or water and trimethoprim 10% pet (Laboratórios Edol©).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Sixty-four patients (48F/16M; mean age 47 ± 18) were included, mostly with maculopapular exanthema (51, 80%). Notably, CTX was sole suspect in 24 patients. There was no positive reaction to CTX at 10% from Chemotechnique or Bactrim DS® tablets prepared at 10% pet for patch testing. One patient reacted exclusively to trimethoprim with 1+ reaction. Two patients had a faint reaction (1+) only with the powder of Bactrim DS® tablets in water at D2, but as the reactions faded completely in 24 or 48 h, they were interpreted as irritant non-specific reactions.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>These findings suggest that patch testing may lack sufficient sensitivity to diagnose CTX-induced non-immediate CADR. Therefore, clinicians should be cautious interpreting CTX patch test results.</p>\\n </section>\\n </div>\",\"PeriodicalId\":4,\"journal\":{\"name\":\"ACS Applied Energy Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2024-09-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Energy Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/cod.14692\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Energy Materials","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cod.14692","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
引用
批量引用