低信噪比异质外延界面原子分辨 HAADF 图像的精确定位。

Kohei Aso, Yoshifumi Oshima
{"title":"低信噪比异质外延界面原子分辨 HAADF 图像的精确定位。","authors":"Kohei Aso, Yoshifumi Oshima","doi":"10.1093/jmicro/dfae038","DOIUrl":null,"url":null,"abstract":"<p><p>Heteroepitaxial interfaces are important because they determine the performance of devices such that career mobility is sensitive to the distribution of roughness, strain and composition at the interface. High-angle annular dark field imaging in scanning transmission electron microscopy has been utilized to capture them at an atomic scale. For precise identification of atomic column positions, a technique has been proposed to average multiple image frames taken at a high scanning rate by their positional alignment for increasing signal-to-noise ratio. However, the positional alignment between frames is sometimes incorrectly estimated because of the almost perfect periodic structure at the interfaces. Here, we developed an approach for precise positional alignment, where the images are first aligned by two consecutive images and then are aligned more precisely against the integrated image of the first alignment. We demonstrated our method by applying it to the heterointerface of Si0.8Ge0.2 (Si: silicon, Ge: germanium) epitaxial thin films on a Si substrate.</p>","PeriodicalId":74193,"journal":{"name":"Microscopy (Oxford, England)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precise positional alignment of atom-resolved HAADF images of heteroepitaxial interface with low signal-to-noise ratio.\",\"authors\":\"Kohei Aso, Yoshifumi Oshima\",\"doi\":\"10.1093/jmicro/dfae038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Heteroepitaxial interfaces are important because they determine the performance of devices such that career mobility is sensitive to the distribution of roughness, strain and composition at the interface. High-angle annular dark field imaging in scanning transmission electron microscopy has been utilized to capture them at an atomic scale. For precise identification of atomic column positions, a technique has been proposed to average multiple image frames taken at a high scanning rate by their positional alignment for increasing signal-to-noise ratio. However, the positional alignment between frames is sometimes incorrectly estimated because of the almost perfect periodic structure at the interfaces. Here, we developed an approach for precise positional alignment, where the images are first aligned by two consecutive images and then are aligned more precisely against the integrated image of the first alignment. We demonstrated our method by applying it to the heterointerface of Si0.8Ge0.2 (Si: silicon, Ge: germanium) epitaxial thin films on a Si substrate.</p>\",\"PeriodicalId\":74193,\"journal\":{\"name\":\"Microscopy (Oxford, England)\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microscopy (Oxford, England)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jmicro/dfae038\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy (Oxford, England)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jmicro/dfae038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

异质外延界面非常重要,因为它们决定了器件的性能,例如职业迁移率对界面的粗糙度、应变和成分分布非常敏感。扫描透射电子显微镜中的高角度环形暗场成像技术可用于捕捉原子尺度的界面。为了精确识别原子柱的位置,有人提出了一种技术,通过位置对齐来平均以高扫描速率拍摄的多个图像帧,以提高信噪比。然而,由于界面上几乎完美的周期性结构,帧间的位置对齐有时会估计错误。在此,我们开发了一种精确位置对齐的方法,即首先通过两幅连续图像对齐图像,然后根据第一幅对齐图像的综合图像进行更精确的对齐。我们将这种方法应用于硅基底上的 Si0.8Ge0.2(Si:硅,Ge:锗)外延薄膜的异质界面,并对其进行了演示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Precise positional alignment of atom-resolved HAADF images of heteroepitaxial interface with low signal-to-noise ratio.

Heteroepitaxial interfaces are important because they determine the performance of devices such that career mobility is sensitive to the distribution of roughness, strain and composition at the interface. High-angle annular dark field imaging in scanning transmission electron microscopy has been utilized to capture them at an atomic scale. For precise identification of atomic column positions, a technique has been proposed to average multiple image frames taken at a high scanning rate by their positional alignment for increasing signal-to-noise ratio. However, the positional alignment between frames is sometimes incorrectly estimated because of the almost perfect periodic structure at the interfaces. Here, we developed an approach for precise positional alignment, where the images are first aligned by two consecutive images and then are aligned more precisely against the integrated image of the first alignment. We demonstrated our method by applying it to the heterointerface of Si0.8Ge0.2 (Si: silicon, Ge: germanium) epitaxial thin films on a Si substrate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Correction to: Low-dose measurement of electric potential distribution in organic light-emitting diode by phase-shifting electron holography with 3D tensor decomposition. Correction to: Structures of multisubunit membrane complexes with the CRYO ARM 200. Momentum-resolved EELS and CL study on 1D-plasmonic crystal prepared by FIB method. Bayesian inference of atomic column positions in scanning transmission electron microscopy images. Fast computational approach with prior dimension reduction for three-dimensional chemical component analysis using CT data of spectral imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1