儿科耐用左心室辅助装置:体型对疗效和尺寸限制的影响。

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Artificial Organs Pub Date : 2024-09-06 DOI:10.1007/s10047-024-01467-7
Mimi Xiaoming Deng, Nao Yoshida, Christoph Haller, Aamir Jeewa, Shi-Joon Yoo, Osami Honjo
{"title":"儿科耐用左心室辅助装置:体型对疗效和尺寸限制的影响。","authors":"Mimi Xiaoming Deng, Nao Yoshida, Christoph Haller, Aamir Jeewa, Shi-Joon Yoo, Osami Honjo","doi":"10.1007/s10047-024-01467-7","DOIUrl":null,"url":null,"abstract":"<p><p>Despite the range of body sizes in children, few ventricular assist devices (VAD) exist to support pediatric patients with end-stage heart failure. Large registry data identified weight < 20 kg to be associated with higher rates of VAD-related stroke, compared to > 40 kg. Moreover, patients < 1 years of age experience the highest post-implant mortality, with 1-year survival improving in an age-dependent manner. Within different VAD types, intracorporeal continuous (IC) devices confer the greatest clinical benefit and quality of life compared to paracorporeal alternatives. The major limitation of IC VADs is the technical challenge of implantation into patients of small body size, thus the majority of patients with IC devices are pre-adolescents or older. However, since 2021, the use of HeartMate 3™ (HM3) has expanded to patients as small as 17.7 kg. Although HM3 offers equally favorable survival outcomes irrespective of body size, patients of low body surface area are more likely to experience non-device-related major infections and renal dysfunction, with suggestion for elevated risk of major bleeding and stroke. Innovative imaging strategies have emerged to assess the feasibility of HM3 implantation and facilitate preoperative planning in small children. Moreover, the unmet need for an IC device in the infant population has revived interest in the axial pump, with a pivotal clinical trial currently underway. VAD outcomes in the pediatric population are not equivalent across all ages and body sizes, thus size-stratified analyses and device development to serve the full spectrum of body habitus are key considerations as this field rapidly evolves.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Durable left ventricular assist devices in pediatrics: impact of body size on outcomes and size limitations.\",\"authors\":\"Mimi Xiaoming Deng, Nao Yoshida, Christoph Haller, Aamir Jeewa, Shi-Joon Yoo, Osami Honjo\",\"doi\":\"10.1007/s10047-024-01467-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Despite the range of body sizes in children, few ventricular assist devices (VAD) exist to support pediatric patients with end-stage heart failure. Large registry data identified weight < 20 kg to be associated with higher rates of VAD-related stroke, compared to > 40 kg. Moreover, patients < 1 years of age experience the highest post-implant mortality, with 1-year survival improving in an age-dependent manner. Within different VAD types, intracorporeal continuous (IC) devices confer the greatest clinical benefit and quality of life compared to paracorporeal alternatives. The major limitation of IC VADs is the technical challenge of implantation into patients of small body size, thus the majority of patients with IC devices are pre-adolescents or older. However, since 2021, the use of HeartMate 3™ (HM3) has expanded to patients as small as 17.7 kg. Although HM3 offers equally favorable survival outcomes irrespective of body size, patients of low body surface area are more likely to experience non-device-related major infections and renal dysfunction, with suggestion for elevated risk of major bleeding and stroke. Innovative imaging strategies have emerged to assess the feasibility of HM3 implantation and facilitate preoperative planning in small children. Moreover, the unmet need for an IC device in the infant population has revived interest in the axial pump, with a pivotal clinical trial currently underway. VAD outcomes in the pediatric population are not equivalent across all ages and body sizes, thus size-stratified analyses and device development to serve the full spectrum of body habitus are key considerations as this field rapidly evolves.</p>\",\"PeriodicalId\":15177,\"journal\":{\"name\":\"Journal of Artificial Organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10047-024-01467-7\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01467-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

尽管儿童的体型大小不一,但用于支持终末期心力衰竭儿科患者的心室辅助装置(VAD)却寥寥无几。大量登记数据显示,儿童体重为 40 千克。此外,患者
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Durable left ventricular assist devices in pediatrics: impact of body size on outcomes and size limitations.

Despite the range of body sizes in children, few ventricular assist devices (VAD) exist to support pediatric patients with end-stage heart failure. Large registry data identified weight < 20 kg to be associated with higher rates of VAD-related stroke, compared to > 40 kg. Moreover, patients < 1 years of age experience the highest post-implant mortality, with 1-year survival improving in an age-dependent manner. Within different VAD types, intracorporeal continuous (IC) devices confer the greatest clinical benefit and quality of life compared to paracorporeal alternatives. The major limitation of IC VADs is the technical challenge of implantation into patients of small body size, thus the majority of patients with IC devices are pre-adolescents or older. However, since 2021, the use of HeartMate 3™ (HM3) has expanded to patients as small as 17.7 kg. Although HM3 offers equally favorable survival outcomes irrespective of body size, patients of low body surface area are more likely to experience non-device-related major infections and renal dysfunction, with suggestion for elevated risk of major bleeding and stroke. Innovative imaging strategies have emerged to assess the feasibility of HM3 implantation and facilitate preoperative planning in small children. Moreover, the unmet need for an IC device in the infant population has revived interest in the axial pump, with a pivotal clinical trial currently underway. VAD outcomes in the pediatric population are not equivalent across all ages and body sizes, thus size-stratified analyses and device development to serve the full spectrum of body habitus are key considerations as this field rapidly evolves.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
期刊最新文献
Exploring the role of plasmapheresis prior to thyroidectomy in managing thyrotoxicosis: a comprehensive scoping review. A compact machine perfusion device for whole blood perfusion in isolated rat liver. Advanced roll porous scaffold 3D bioprinting technology. Impact of the spleen size on short-term prognosis in patients with cardiogenic shock receiving Impella-incorporated temporary mechanical circulatory support Axial-flow polymer bridge pump with hydrodynamic bearings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1