700 千伏脉冲发生器,上升时间约为几纳秒。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-09-01 DOI:10.1063/5.0222037
Junna Li, Yongliang Wang, Xiaoyu Zhou, Haoliang Shi, Fangzheng Wu, Qixiang Huang, Qisheng Li, Yiting Zhang
{"title":"700 千伏脉冲发生器,上升时间约为几纳秒。","authors":"Junna Li, Yongliang Wang, Xiaoyu Zhou, Haoliang Shi, Fangzheng Wu, Qixiang Huang, Qisheng Li, Yiting Zhang","doi":"10.1063/5.0222037","DOIUrl":null,"url":null,"abstract":"<p><p>Pulse generators with high voltage and several nanoseconds of rise time are typically used to carry out the equivalent assessment of the protection performance of typical power equipment in the high-altitude electromagnetic pulse environment. In this paper, a pulse generator with high voltage and fast rise time has been designed, and the diagnostic system with high temporal resolution has been integrated to measure the output pulse voltage of the generator. The experimental results showed that the output pulse voltage of the generator on the output load can reach 645 kV when the charged voltage of Marx generator capacitors is 40 kV. The rise time of the generator is 8.2-9.9 ns when the charged voltage of Marx generator capacitors is in the range of 20-40 kV.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A 700 kV pulse generator with a rise time on the order of several nanoseconds.\",\"authors\":\"Junna Li, Yongliang Wang, Xiaoyu Zhou, Haoliang Shi, Fangzheng Wu, Qixiang Huang, Qisheng Li, Yiting Zhang\",\"doi\":\"10.1063/5.0222037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Pulse generators with high voltage and several nanoseconds of rise time are typically used to carry out the equivalent assessment of the protection performance of typical power equipment in the high-altitude electromagnetic pulse environment. In this paper, a pulse generator with high voltage and fast rise time has been designed, and the diagnostic system with high temporal resolution has been integrated to measure the output pulse voltage of the generator. The experimental results showed that the output pulse voltage of the generator on the output load can reach 645 kV when the charged voltage of Marx generator capacitors is 40 kV. The rise time of the generator is 8.2-9.9 ns when the charged voltage of Marx generator capacitors is in the range of 20-40 kV.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0222037\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0222037","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

高电压和几纳秒上升时间的脉冲发生器通常用于在高空电磁脉冲环境下对典型电力设备的保护性能进行等效评估。本文设计了一种具有高电压和快速上升时间的脉冲发生器,并集成了具有高时间分辨率的诊断系统来测量发生器的输出脉冲电压。实验结果表明,当 Marx 发电机电容器的带电电压为 40 kV 时,发电机在输出负载上的输出脉冲电压可达 645 kV。当 Marx 发生器电容器的充电电压在 20-40 kV 范围内时,发生器的上升时间为 8.2-9.9 ns。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A 700 kV pulse generator with a rise time on the order of several nanoseconds.

Pulse generators with high voltage and several nanoseconds of rise time are typically used to carry out the equivalent assessment of the protection performance of typical power equipment in the high-altitude electromagnetic pulse environment. In this paper, a pulse generator with high voltage and fast rise time has been designed, and the diagnostic system with high temporal resolution has been integrated to measure the output pulse voltage of the generator. The experimental results showed that the output pulse voltage of the generator on the output load can reach 645 kV when the charged voltage of Marx generator capacitors is 40 kV. The rise time of the generator is 8.2-9.9 ns when the charged voltage of Marx generator capacitors is in the range of 20-40 kV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Mentorship in academic musculoskeletal radiology: perspectives from a junior faculty member. Underlying synovial sarcoma undiagnosed for more than 20 years in a patient with regional pain: a case report. Sacrococcygeal chordoma with spontaneous regression due to a large hemorrhagic component. Associations of cumulative voriconazole dose, treatment duration, and alkaline phosphatase with voriconazole-induced periostitis. Can the presence of SLAP-5 lesions be predicted by using the critical shoulder angle in traumatic anterior shoulder instability?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1