使用纳米纤维空气过滤器的飞机模拟舱内人际粒子传输实验研究。

IF 8.2 1区 环境科学与生态学 Q1 ENVIRONMENTAL SCIENCES Science of the Total Environment Pub Date : 2024-12-01 Epub Date: 2024-09-04 DOI:10.1016/j.scitotenv.2024.176059
Haiqiang Zhang, Yue Pan, Chengzhong Deng, Zhuolun Niu, Ruoyu You, Chun Chen
{"title":"使用纳米纤维空气过滤器的飞机模拟舱内人际粒子传输实验研究。","authors":"Haiqiang Zhang, Yue Pan, Chengzhong Deng, Zhuolun Niu, Ruoyu You, Chun Chen","doi":"10.1016/j.scitotenv.2024.176059","DOIUrl":null,"url":null,"abstract":"<p><p>Improving aircraft environmental control systems could reduce the risk of airborne infectious disease transmission in aircraft cabins. The high-efficiency particulate air (HEPA) filters used in the existing systems exhibit high pressure drop, which results in high consumption of energy and fuel. Nanofiber air filters fabricated by electrospinning can reduce pressure drop, but their performance in aircraft cabins is unknown. Therefore, this study experimentally investigated the interpersonal particle transport in an aircraft cabin mockup with nanofiber air filters. First, a full-scale, fully occupied, 7-row, single-aisle aircraft cabin mockup was constructed. Nanofiber filtration units were fabricated using the electrospinning technique. Under the well-sealed laboratory testing conditions, both the small-scale nanofiber and HEPA filter media exhibited a particle removal efficiency of around 99 %. The performance of nanofiber and HEPA filtration units installed in the environmental control system of the mockup was then measured. Finally, the interpersonal particle transport in the cabin was measured. The results show that the particle removal efficiency of the nanofiber filtration units installed in the environmental control system ranged from 64 to 72 % when the particle size was 0.3-0.4 μm, which primarily reflected the large air leakages associated with the filter installation. At the filter media level, the pressure drop across the nanofiber units in the mockup was 61-67 % lower than that across the HEPA units under the same airflow rate, which however may not necessarily translate into lower pressure drop for actual filters in aircraft due to the potentially different design in terms of media face area. The average normalized particle concentration in the breathing zones of fellow passengers in the cabin mockup with the nanofiber filtration units was by 0.23, 0.29, and 0.32, respectively, when the index passenger was seated at the window, middle, and aisle.</p>","PeriodicalId":422,"journal":{"name":"Science of the Total Environment","volume":null,"pages":null},"PeriodicalIF":8.2000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental investigation of interpersonal particle transport in an aircraft cabin mockup with nanofiber air filters.\",\"authors\":\"Haiqiang Zhang, Yue Pan, Chengzhong Deng, Zhuolun Niu, Ruoyu You, Chun Chen\",\"doi\":\"10.1016/j.scitotenv.2024.176059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Improving aircraft environmental control systems could reduce the risk of airborne infectious disease transmission in aircraft cabins. The high-efficiency particulate air (HEPA) filters used in the existing systems exhibit high pressure drop, which results in high consumption of energy and fuel. Nanofiber air filters fabricated by electrospinning can reduce pressure drop, but their performance in aircraft cabins is unknown. Therefore, this study experimentally investigated the interpersonal particle transport in an aircraft cabin mockup with nanofiber air filters. First, a full-scale, fully occupied, 7-row, single-aisle aircraft cabin mockup was constructed. Nanofiber filtration units were fabricated using the electrospinning technique. Under the well-sealed laboratory testing conditions, both the small-scale nanofiber and HEPA filter media exhibited a particle removal efficiency of around 99 %. The performance of nanofiber and HEPA filtration units installed in the environmental control system of the mockup was then measured. Finally, the interpersonal particle transport in the cabin was measured. The results show that the particle removal efficiency of the nanofiber filtration units installed in the environmental control system ranged from 64 to 72 % when the particle size was 0.3-0.4 μm, which primarily reflected the large air leakages associated with the filter installation. At the filter media level, the pressure drop across the nanofiber units in the mockup was 61-67 % lower than that across the HEPA units under the same airflow rate, which however may not necessarily translate into lower pressure drop for actual filters in aircraft due to the potentially different design in terms of media face area. The average normalized particle concentration in the breathing zones of fellow passengers in the cabin mockup with the nanofiber filtration units was by 0.23, 0.29, and 0.32, respectively, when the index passenger was seated at the window, middle, and aisle.</p>\",\"PeriodicalId\":422,\"journal\":{\"name\":\"Science of the Total Environment\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Science of the Total Environment\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1016/j.scitotenv.2024.176059\",\"RegionNum\":1,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science of the Total Environment","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1016/j.scitotenv.2024.176059","RegionNum":1,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/4 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

改进飞机环境控制系统可以降低飞机客舱内空气传播传染病的风险。现有系统中使用的高效微粒空气过滤器(HEPA)压降大,导致能源和燃料消耗高。通过电纺丝制造的纳米纤维空气过滤器可以降低压降,但其在飞机客舱中的性能尚不清楚。因此,本研究利用纳米纤维空气过滤器对飞机模拟舱内的人际粒子传输进行了实验研究。首先,构建了一个全尺寸、满员、7 排、单通道飞机模拟机舱。使用电纺丝技术制造了纳米纤维过滤装置。在密封良好的实验室测试条件下,小型纳米纤维和 HEPA 过滤介质的颗粒去除率均达到 99% 左右。然后测量了安装在模拟环境控制系统中的纳米纤维和 HEPA 过滤装置的性能。最后,测量了机舱内的人际粒子传输。结果表明,当颗粒大小为 0.3-0.4 μm 时,安装在环境控制系统中的纳米纤维过滤装置的颗粒去除效率为 64% 到 72%,这主要反映了与过滤器安装相关的大量空气泄漏。在过滤介质层面,在相同的气流速率下,模拟装置中纳米纤维单元的压降比高效过滤器单元的压降低 61-67%,但这并不一定会转化为飞机上实际过滤器的较低压降,因为在介质面面积方面可能存在不同的设计。在装有纳米纤维过滤装置的模拟客舱中,当指标乘客坐在靠窗、中间和过道位置时,其他乘客呼吸区的平均归一化颗粒浓度分别降低了 0.23、0.29 和 0.32。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental investigation of interpersonal particle transport in an aircraft cabin mockup with nanofiber air filters.

Improving aircraft environmental control systems could reduce the risk of airborne infectious disease transmission in aircraft cabins. The high-efficiency particulate air (HEPA) filters used in the existing systems exhibit high pressure drop, which results in high consumption of energy and fuel. Nanofiber air filters fabricated by electrospinning can reduce pressure drop, but their performance in aircraft cabins is unknown. Therefore, this study experimentally investigated the interpersonal particle transport in an aircraft cabin mockup with nanofiber air filters. First, a full-scale, fully occupied, 7-row, single-aisle aircraft cabin mockup was constructed. Nanofiber filtration units were fabricated using the electrospinning technique. Under the well-sealed laboratory testing conditions, both the small-scale nanofiber and HEPA filter media exhibited a particle removal efficiency of around 99 %. The performance of nanofiber and HEPA filtration units installed in the environmental control system of the mockup was then measured. Finally, the interpersonal particle transport in the cabin was measured. The results show that the particle removal efficiency of the nanofiber filtration units installed in the environmental control system ranged from 64 to 72 % when the particle size was 0.3-0.4 μm, which primarily reflected the large air leakages associated with the filter installation. At the filter media level, the pressure drop across the nanofiber units in the mockup was 61-67 % lower than that across the HEPA units under the same airflow rate, which however may not necessarily translate into lower pressure drop for actual filters in aircraft due to the potentially different design in terms of media face area. The average normalized particle concentration in the breathing zones of fellow passengers in the cabin mockup with the nanofiber filtration units was by 0.23, 0.29, and 0.32, respectively, when the index passenger was seated at the window, middle, and aisle.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Science of the Total Environment
Science of the Total Environment 环境科学-环境科学
CiteScore
17.60
自引率
10.20%
发文量
8726
审稿时长
2.4 months
期刊介绍: The Science of the Total Environment is an international journal dedicated to scientific research on the environment and its interaction with humanity. It covers a wide range of disciplines and seeks to publish innovative, hypothesis-driven, and impactful research that explores the entire environment, including the atmosphere, lithosphere, hydrosphere, biosphere, and anthroposphere. The journal's updated Aims & Scope emphasizes the importance of interdisciplinary environmental research with broad impact. Priority is given to studies that advance fundamental understanding and explore the interconnectedness of multiple environmental spheres. Field studies are preferred, while laboratory experiments must demonstrate significant methodological advancements or mechanistic insights with direct relevance to the environment.
期刊最新文献
Factors contributing to pesticide contamination in riverine systems: The role of wastewater and landscape sources. Neglecting biodiversity baselines in longitudinal river connectivity restoration impacts priority setting. Identifying patterns of microplastic accumulation in coastal vegetated habitats: A systematic review and meta-analysis. Chronic bisphenol A induced neurotoxicity: Exposure risk, molecular fate within carp and its potential phytoremediation. Experimental investigation of interpersonal particle transport in an aircraft cabin mockup with nanofiber air filters.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1