使用替代材料对新型肱骨近端骨折钢板进行生物力学设计。

IF 2.2 4区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal for Numerical Methods in Biomedical Engineering Pub Date : 2024-09-07 DOI:10.1002/cnm.3868
Sabrina Islam, Mitchell Dembowski, Emil H Schemitsch, Habiba Bougherara, Z Shaghayegh Bagheri, Radovan Zdero
{"title":"使用替代材料对新型肱骨近端骨折钢板进行生物力学设计。","authors":"Sabrina Islam, Mitchell Dembowski, Emil H Schemitsch, Habiba Bougherara, Z Shaghayegh Bagheri, Radovan Zdero","doi":"10.1002/cnm.3868","DOIUrl":null,"url":null,"abstract":"<p><p>Comminuted proximal humerus fractures are often repaired by metal plates, but potentially still experience bone refracture, bone \"stress shielding,\" screw perforation, delayed healing, and so forth. This \"proof of principle\" investigation is the initial step towards the design of a new plate using alternative materials to address some of these problems. Finite element modeling was used to create design graphs for bone stress, plate stress, screw stress, and interfragmentary motion via three different fixations (no, 1, or 2 \"kickstand\" [KS] screws across the fracture) using a wide range of plate elastic moduli (E<sub>P</sub> = 5-200 GPa). Well-known design optimization criteria were used that could minimize bone, plate, and screw failure (i.e., peak stress < ultimate tensile strength), reduce bone \"stress shielding\" (i.e., bone stress under the new plate ≥ bone stress for an intact humerus, titanium plate, and/or steel plate \"control\"), and encourage callus growth leading to early healing (i.e., 0.2 mm ≤ axial interfragmentary motion ≤ 1 mm; shear/axial interfragmentary motion ratio <1.6). The findings suggest that a potentially optimal configuration involves the new plate being manufactured from a material with an E<sub>P</sub> of 5-41.5 GPa with 1 KS screw; but, using no KS screws would cause immediate bone fracture and 2 KS screws would almost certainly lead to delayed healing. A prototype plate might be fabricated using alternative materials suggested for orthopedics and other industries, like fiber-metal laminates, fiber-reinforced polymers, metal foams, pure polymers, shape memory alloys, or 3D-printed porous metals.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanical design of a new proximal humerus fracture plate using alternative materials.\",\"authors\":\"Sabrina Islam, Mitchell Dembowski, Emil H Schemitsch, Habiba Bougherara, Z Shaghayegh Bagheri, Radovan Zdero\",\"doi\":\"10.1002/cnm.3868\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Comminuted proximal humerus fractures are often repaired by metal plates, but potentially still experience bone refracture, bone \\\"stress shielding,\\\" screw perforation, delayed healing, and so forth. This \\\"proof of principle\\\" investigation is the initial step towards the design of a new plate using alternative materials to address some of these problems. Finite element modeling was used to create design graphs for bone stress, plate stress, screw stress, and interfragmentary motion via three different fixations (no, 1, or 2 \\\"kickstand\\\" [KS] screws across the fracture) using a wide range of plate elastic moduli (E<sub>P</sub> = 5-200 GPa). Well-known design optimization criteria were used that could minimize bone, plate, and screw failure (i.e., peak stress < ultimate tensile strength), reduce bone \\\"stress shielding\\\" (i.e., bone stress under the new plate ≥ bone stress for an intact humerus, titanium plate, and/or steel plate \\\"control\\\"), and encourage callus growth leading to early healing (i.e., 0.2 mm ≤ axial interfragmentary motion ≤ 1 mm; shear/axial interfragmentary motion ratio <1.6). The findings suggest that a potentially optimal configuration involves the new plate being manufactured from a material with an E<sub>P</sub> of 5-41.5 GPa with 1 KS screw; but, using no KS screws would cause immediate bone fracture and 2 KS screws would almost certainly lead to delayed healing. A prototype plate might be fabricated using alternative materials suggested for orthopedics and other industries, like fiber-metal laminates, fiber-reinforced polymers, metal foams, pure polymers, shape memory alloys, or 3D-printed porous metals.</p>\",\"PeriodicalId\":50349,\"journal\":{\"name\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/cnm.3868\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/cnm.3868","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

肱骨近端粉碎性骨折通常使用金属板进行修复,但仍可能出现骨折断、骨 "应力屏蔽"、螺钉穿孔、愈合延迟等问题。这项 "原理验证 "调查是使用替代材料设计新钢板以解决其中一些问题的第一步。通过有限元建模,我们利用广泛的钢板弹性模量(EP = 5-200 GPa),通过三种不同的固定方式(无、1 或 2 个横跨骨折的 "脚架"[KS] 螺钉)创建了骨应力、钢板应力、螺钉应力和节间运动的设计图。我们采用了众所周知的优化设计标准,可以最大限度地减少骨、钢板和螺钉的失效(即使用 1 颗 KS 螺钉时,峰值应力 P 为 5-41.5 GPa;但是,不使用 KS 螺钉会导致立即骨折,而使用 2 颗 KS 螺钉几乎肯定会导致延迟愈合。可以使用骨科和其他行业建议的替代材料,如纤维金属层压板、纤维增强聚合物、金属泡沫、纯聚合物、形状记忆合金或 3D 打印多孔金属,来制造钢板原型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Biomechanical design of a new proximal humerus fracture plate using alternative materials.

Comminuted proximal humerus fractures are often repaired by metal plates, but potentially still experience bone refracture, bone "stress shielding," screw perforation, delayed healing, and so forth. This "proof of principle" investigation is the initial step towards the design of a new plate using alternative materials to address some of these problems. Finite element modeling was used to create design graphs for bone stress, plate stress, screw stress, and interfragmentary motion via three different fixations (no, 1, or 2 "kickstand" [KS] screws across the fracture) using a wide range of plate elastic moduli (EP = 5-200 GPa). Well-known design optimization criteria were used that could minimize bone, plate, and screw failure (i.e., peak stress < ultimate tensile strength), reduce bone "stress shielding" (i.e., bone stress under the new plate ≥ bone stress for an intact humerus, titanium plate, and/or steel plate "control"), and encourage callus growth leading to early healing (i.e., 0.2 mm ≤ axial interfragmentary motion ≤ 1 mm; shear/axial interfragmentary motion ratio <1.6). The findings suggest that a potentially optimal configuration involves the new plate being manufactured from a material with an EP of 5-41.5 GPa with 1 KS screw; but, using no KS screws would cause immediate bone fracture and 2 KS screws would almost certainly lead to delayed healing. A prototype plate might be fabricated using alternative materials suggested for orthopedics and other industries, like fiber-metal laminates, fiber-reinforced polymers, metal foams, pure polymers, shape memory alloys, or 3D-printed porous metals.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
期刊最新文献
Issue Information Model order reduction and sensitivity analysis for complex heat transfer simulations inside the human eyeball. Biomechanical design of a new proximal humerus fracture plate using alternative materials. Uncertainty quantification of the pressure waveform using a Windkessel model. A semi-automatic method for block-structured hexahedral meshing of aortic dissections.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1