Martin Lippmann, Moritz Hitzemann, Jonas Winkelholz, David Bailey, Stefan Zimmermann
{"title":"应用于离子迁移谱仪的模块化隔离高压开关","authors":"Martin Lippmann, Moritz Hitzemann, Jonas Winkelholz, David Bailey, Stefan Zimmermann","doi":"10.1016/j.ohx.2024.e00574","DOIUrl":null,"url":null,"abstract":"<div><p>Ion mobility spectrometry is an emerging technology in trace gas analysis that has moved from typical safety and security applications to many other fields ranging from environmental and food quality monitoring to medicine and life sciences. Nevertheless, further dissemination, including the development of new instruments and the expansion into new fields of application requires the availability of the fundamental components of ion mobility spectrometers. For example, the electronics is essential for the analytical performance, but is only provided by specialized manufacturers due to specific requirements. In this paper, we present a modular, isolated high-voltage switch that can be operated at an isolated potential. The modular design enables tailoring its configuration to the required application. Each module can switch a voltage of up to 3 kV, and can be operated with an offset voltage of up to 7 kV. The switch has rise and fall times of less than 25 ns, making it suitable for a wide range of applications, e.g., in ion mobility spectrometry. Finally, the presented modular, isolated high-voltage switch was used in a push–pull configuration to generate the injection pulse of the ion gate. The new modular, isolated high-voltage switch shows similar performance compared to a commercially available high-voltage switch.</p></div>","PeriodicalId":37503,"journal":{"name":"HardwareX","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2468067224000683/pdfft?md5=c0b7647745783914fcf83f5f4a8efb0d&pid=1-s2.0-S2468067224000683-main.pdf","citationCount":"0","resultStr":"{\"title\":\"A modular, isolated high-voltage switch for application in ion mobility spectrometry\",\"authors\":\"Martin Lippmann, Moritz Hitzemann, Jonas Winkelholz, David Bailey, Stefan Zimmermann\",\"doi\":\"10.1016/j.ohx.2024.e00574\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Ion mobility spectrometry is an emerging technology in trace gas analysis that has moved from typical safety and security applications to many other fields ranging from environmental and food quality monitoring to medicine and life sciences. Nevertheless, further dissemination, including the development of new instruments and the expansion into new fields of application requires the availability of the fundamental components of ion mobility spectrometers. For example, the electronics is essential for the analytical performance, but is only provided by specialized manufacturers due to specific requirements. In this paper, we present a modular, isolated high-voltage switch that can be operated at an isolated potential. The modular design enables tailoring its configuration to the required application. Each module can switch a voltage of up to 3 kV, and can be operated with an offset voltage of up to 7 kV. The switch has rise and fall times of less than 25 ns, making it suitable for a wide range of applications, e.g., in ion mobility spectrometry. Finally, the presented modular, isolated high-voltage switch was used in a push–pull configuration to generate the injection pulse of the ion gate. The new modular, isolated high-voltage switch shows similar performance compared to a commercially available high-voltage switch.</p></div>\",\"PeriodicalId\":37503,\"journal\":{\"name\":\"HardwareX\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2468067224000683/pdfft?md5=c0b7647745783914fcf83f5f4a8efb0d&pid=1-s2.0-S2468067224000683-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HardwareX\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2468067224000683\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HardwareX","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468067224000683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
A modular, isolated high-voltage switch for application in ion mobility spectrometry
Ion mobility spectrometry is an emerging technology in trace gas analysis that has moved from typical safety and security applications to many other fields ranging from environmental and food quality monitoring to medicine and life sciences. Nevertheless, further dissemination, including the development of new instruments and the expansion into new fields of application requires the availability of the fundamental components of ion mobility spectrometers. For example, the electronics is essential for the analytical performance, but is only provided by specialized manufacturers due to specific requirements. In this paper, we present a modular, isolated high-voltage switch that can be operated at an isolated potential. The modular design enables tailoring its configuration to the required application. Each module can switch a voltage of up to 3 kV, and can be operated with an offset voltage of up to 7 kV. The switch has rise and fall times of less than 25 ns, making it suitable for a wide range of applications, e.g., in ion mobility spectrometry. Finally, the presented modular, isolated high-voltage switch was used in a push–pull configuration to generate the injection pulse of the ion gate. The new modular, isolated high-voltage switch shows similar performance compared to a commercially available high-voltage switch.
HardwareXEngineering-Industrial and Manufacturing Engineering
CiteScore
4.10
自引率
18.20%
发文量
124
审稿时长
24 weeks
期刊介绍:
HardwareX is an open access journal established to promote free and open source designing, building and customizing of scientific infrastructure (hardware). HardwareX aims to recognize researchers for the time and effort in developing scientific infrastructure while providing end-users with sufficient information to replicate and validate the advances presented. HardwareX is open to input from all scientific, technological and medical disciplines. Scientific infrastructure will be interpreted in the broadest sense. Including hardware modifications to existing infrastructure, sensors and tools that perform measurements and other functions outside of the traditional lab setting (such as wearables, air/water quality sensors, and low cost alternatives to existing tools), and the creation of wholly new tools for either standard or novel laboratory tasks. Authors are encouraged to submit hardware developments that address all aspects of science, not only the final measurement, for example, enhancements in sample preparation and handling, user safety, and quality control. The use of distributed digital manufacturing strategies (e.g. 3-D printing) is encouraged. All designs must be submitted under an open hardware license.