{"title":"使用掺硼金刚石电极检测盐酸奎宁的研究","authors":"Meutya Dwi Leoriza ,&nbsp;Nessa Sabriena ,&nbsp;Muhammad Raihan Ramadhan ,&nbsp;Gusti Umindya Nur Tajalla ,&nbsp;Dewi Umaningrum ,&nbsp;Andi Idhil Ismail ,&nbsp;Genki Ogata ,&nbsp;Yasuaki Einaga ,&nbsp;Yunita Triana","doi":"10.1016/j.ijoes.2024.100778","DOIUrl":null,"url":null,"abstract":"<div><p>This study investigates the electrochemical properties of quinine hydrochloride (QH) using boron-doped diamond (BDD) electrodes. The redox behavior of QH was analyzed and compared in phosphate buffer solution (PBS) and potassium perchlorate (KClO<sub>4</sub>) electrolyte, observing an increase in current response with hydrogen-terminated BDD (H-BDD) electrodes. A cyclic voltammogram of QH in 0.1 M PBS and 0.1 M KClO<sub>4</sub> shows a reduction peak at −1.14 V (<em>vs. Ag/AgCl</em>). The scan rate dependence was examined to understand the reduction mechanism involving two electrons. A linear calibration curve was noted from 2 μM to 25 μM range (R<sup>2</sup> = 0.99) with detection limits of 0.18 μM in PBS and 0.16 μM in KClO<sub>4</sub>. The BDD electrodes demonstrated good selectivity in tonic water with sharp oxidation potentials for QH, confirming their stability for QH detection.</p></div>","PeriodicalId":13872,"journal":{"name":"International Journal of Electrochemical Science","volume":"19 10","pages":"Article 100778"},"PeriodicalIF":1.3000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1452398124003195/pdfft?md5=61df8f7745992cb36f2482545d8f4606&pid=1-s2.0-S1452398124003195-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Study of quinine hydrochloride detection using boron-doped diamond electrodes\",\"authors\":\"Meutya Dwi Leoriza ,&nbsp;Nessa Sabriena ,&nbsp;Muhammad Raihan Ramadhan ,&nbsp;Gusti Umindya Nur Tajalla ,&nbsp;Dewi Umaningrum ,&nbsp;Andi Idhil Ismail ,&nbsp;Genki Ogata ,&nbsp;Yasuaki Einaga ,&nbsp;Yunita Triana\",\"doi\":\"10.1016/j.ijoes.2024.100778\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This study investigates the electrochemical properties of quinine hydrochloride (QH) using boron-doped diamond (BDD) electrodes. The redox behavior of QH was analyzed and compared in phosphate buffer solution (PBS) and potassium perchlorate (KClO<sub>4</sub>) electrolyte, observing an increase in current response with hydrogen-terminated BDD (H-BDD) electrodes. A cyclic voltammogram of QH in 0.1 M PBS and 0.1 M KClO<sub>4</sub> shows a reduction peak at −1.14 V (<em>vs. Ag/AgCl</em>). The scan rate dependence was examined to understand the reduction mechanism involving two electrons. A linear calibration curve was noted from 2 μM to 25 μM range (R<sup>2</sup> = 0.99) with detection limits of 0.18 μM in PBS and 0.16 μM in KClO<sub>4</sub>. The BDD electrodes demonstrated good selectivity in tonic water with sharp oxidation potentials for QH, confirming their stability for QH detection.</p></div>\",\"PeriodicalId\":13872,\"journal\":{\"name\":\"International Journal of Electrochemical Science\",\"volume\":\"19 10\",\"pages\":\"Article 100778\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1452398124003195/pdfft?md5=61df8f7745992cb36f2482545d8f4606&pid=1-s2.0-S1452398124003195-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Electrochemical Science\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1452398124003195\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrochemical Science","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1452398124003195","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

摘要

本研究利用掺硼金刚石(BDD)电极研究了盐酸奎宁(QH)的电化学特性。在磷酸盐缓冲溶液(PBS)和高氯酸钾(KClO4)电解液中分析和比较了奎宁盐酸盐(QH)的氧化还原行为,观察到氢端 BDD(H-BDD)电极的电流响应增加。QH 在 0.1 M PBS 和 0.1 M KClO4 中的循环伏安图显示,在 -1.14 V 处有一个还原峰(相对于 Ag/AgCl)。为了了解涉及两个电子的还原机制,对扫描速率依赖性进行了研究。在 2 μM 至 25 μM 范围内形成了线性校准曲线(R2 = 0.99),在 PBS 中的检测限为 0.18 μM,在 KClO4 中的检测限为 0.16 μM。BDD 电极在补水中表现出良好的选择性,对 QH 的氧化电位很高,这证实了它们在检测 QH 方面的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study of quinine hydrochloride detection using boron-doped diamond electrodes

This study investigates the electrochemical properties of quinine hydrochloride (QH) using boron-doped diamond (BDD) electrodes. The redox behavior of QH was analyzed and compared in phosphate buffer solution (PBS) and potassium perchlorate (KClO4) electrolyte, observing an increase in current response with hydrogen-terminated BDD (H-BDD) electrodes. A cyclic voltammogram of QH in 0.1 M PBS and 0.1 M KClO4 shows a reduction peak at −1.14 V (vs. Ag/AgCl). The scan rate dependence was examined to understand the reduction mechanism involving two electrons. A linear calibration curve was noted from 2 μM to 25 μM range (R2 = 0.99) with detection limits of 0.18 μM in PBS and 0.16 μM in KClO4. The BDD electrodes demonstrated good selectivity in tonic water with sharp oxidation potentials for QH, confirming their stability for QH detection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.00
自引率
20.00%
发文量
714
审稿时长
2.6 months
期刊介绍: International Journal of Electrochemical Science is a peer-reviewed, open access journal that publishes original research articles, short communications as well as review articles in all areas of electrochemistry: Scope - Theoretical and Computational Electrochemistry - Processes on Electrodes - Electroanalytical Chemistry and Sensor Science - Corrosion - Electrochemical Energy Conversion and Storage - Electrochemical Engineering - Coatings - Electrochemical Synthesis - Bioelectrochemistry - Molecular Electrochemistry
期刊最新文献
Editorial Board Front Matter1:Full Title Page Retraction notice to ‘Electrochemical behavior of salbutamol, clenbuterol, ractopamine and albuterol at CNTs/GCE’ [Int. J. Electrochem. Sci. 17/5 (2022) 220567] Retraction notice to “Fe–Co co-doped 1D@2D carbon-based composite as an efficient catalyst for Zn-air batteries” [Int. J. Electrochem. Sci., 19 (2024) 100766] Robust lithium-ion battery state of health estimation based on recursive feature elimination-deep Bidirectional long short-term memory model using partial charging data
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1