基于先验知识的嵌入式 U-Net 全自动测量三维超声图像中的颈动脉血管壁容积

Zheng Yue;Jiayao Jiang;Wenguang Hou;Quan Zhou;J. David Spence;Aaron Fenster;Wu Qiu;Mingyue Ding
{"title":"基于先验知识的嵌入式 U-Net 全自动测量三维超声图像中的颈动脉血管壁容积","authors":"Zheng Yue;Jiayao Jiang;Wenguang Hou;Quan Zhou;J. David Spence;Aaron Fenster;Wu Qiu;Mingyue Ding","doi":"10.1109/TMI.2024.3457245","DOIUrl":null,"url":null,"abstract":"The vessel-wall-volume (VWV) measured based on three-dimensional (3D) carotid artery (CA) ultrasound (US) images can help to assess carotid atherosclerosis and manage patients at risk for stroke. Manual involvement for measurement work is subjective and requires well-trained operators, and fully automatic measurement tools are not yet available. Thereby, we proposed a fully automatic VWV measurement framework (Auto-VWV) using a CA prior-knowledge embedded U-Net (CAP-UNet) to measure the VWV from 3D CA US images without manual intervention. The Auto-VWV framework is designed to improve the repeated VWV measuring consistency, which resulted in the first fully automatic framework for VWV measurement. CAP-UNet is developed to improve segmentation accuracy on the whole CA, which composed of a U-Net type backbone and three additional prior-knowledge learning modules. Specifically, a continuity learning module is used to learn the spatial continuity of the arteries in a sequence of image slices. A voxel evolution learning module was designed to learn the evolution of the artery in adjacent slices, and a topology learning module was used to learn the unique topology of the carotid artery. In two 3D CA US datasets, CAP-UNet architecture achieved state-of-the-art performance compared to eight competing models. Furthermore, CAP-UNet-based Auto-VWV achieved better accuracy and consistency than Auto-VWV based on competing models in the simulated repeated measurement. Finally, using 10 pairs of real repeatedly scanned samples, Auto-VWV achieved better VWV measurement reproducibility than intra- and inter-operator manual measurements. The code is available at <uri>https://github.com/Yue9603/Auto-VWV</uri>.","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"44 2","pages":"711-727"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prior-Knowledge Embedded U-Net-Based Fully Automatic Vessel Wall Volume Measurement of the Carotid Artery in 3D Ultrasound Image\",\"authors\":\"Zheng Yue;Jiayao Jiang;Wenguang Hou;Quan Zhou;J. David Spence;Aaron Fenster;Wu Qiu;Mingyue Ding\",\"doi\":\"10.1109/TMI.2024.3457245\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The vessel-wall-volume (VWV) measured based on three-dimensional (3D) carotid artery (CA) ultrasound (US) images can help to assess carotid atherosclerosis and manage patients at risk for stroke. Manual involvement for measurement work is subjective and requires well-trained operators, and fully automatic measurement tools are not yet available. Thereby, we proposed a fully automatic VWV measurement framework (Auto-VWV) using a CA prior-knowledge embedded U-Net (CAP-UNet) to measure the VWV from 3D CA US images without manual intervention. The Auto-VWV framework is designed to improve the repeated VWV measuring consistency, which resulted in the first fully automatic framework for VWV measurement. CAP-UNet is developed to improve segmentation accuracy on the whole CA, which composed of a U-Net type backbone and three additional prior-knowledge learning modules. Specifically, a continuity learning module is used to learn the spatial continuity of the arteries in a sequence of image slices. A voxel evolution learning module was designed to learn the evolution of the artery in adjacent slices, and a topology learning module was used to learn the unique topology of the carotid artery. In two 3D CA US datasets, CAP-UNet architecture achieved state-of-the-art performance compared to eight competing models. Furthermore, CAP-UNet-based Auto-VWV achieved better accuracy and consistency than Auto-VWV based on competing models in the simulated repeated measurement. Finally, using 10 pairs of real repeatedly scanned samples, Auto-VWV achieved better VWV measurement reproducibility than intra- and inter-operator manual measurements. The code is available at <uri>https://github.com/Yue9603/Auto-VWV</uri>.\",\"PeriodicalId\":94033,\"journal\":{\"name\":\"IEEE transactions on medical imaging\",\"volume\":\"44 2\",\"pages\":\"711-727\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on medical imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10672557/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10672557/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Prior-Knowledge Embedded U-Net-Based Fully Automatic Vessel Wall Volume Measurement of the Carotid Artery in 3D Ultrasound Image
The vessel-wall-volume (VWV) measured based on three-dimensional (3D) carotid artery (CA) ultrasound (US) images can help to assess carotid atherosclerosis and manage patients at risk for stroke. Manual involvement for measurement work is subjective and requires well-trained operators, and fully automatic measurement tools are not yet available. Thereby, we proposed a fully automatic VWV measurement framework (Auto-VWV) using a CA prior-knowledge embedded U-Net (CAP-UNet) to measure the VWV from 3D CA US images without manual intervention. The Auto-VWV framework is designed to improve the repeated VWV measuring consistency, which resulted in the first fully automatic framework for VWV measurement. CAP-UNet is developed to improve segmentation accuracy on the whole CA, which composed of a U-Net type backbone and three additional prior-knowledge learning modules. Specifically, a continuity learning module is used to learn the spatial continuity of the arteries in a sequence of image slices. A voxel evolution learning module was designed to learn the evolution of the artery in adjacent slices, and a topology learning module was used to learn the unique topology of the carotid artery. In two 3D CA US datasets, CAP-UNet architecture achieved state-of-the-art performance compared to eight competing models. Furthermore, CAP-UNet-based Auto-VWV achieved better accuracy and consistency than Auto-VWV based on competing models in the simulated repeated measurement. Finally, using 10 pairs of real repeatedly scanned samples, Auto-VWV achieved better VWV measurement reproducibility than intra- and inter-operator manual measurements. The code is available at https://github.com/Yue9603/Auto-VWV.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Table of Contents Table of Contents Table of Contents Building a Synthetic Vascular Model: Evaluation in an Intracranial Aneurysms Detection Scenario. FAMF-Net: Feature Alignment Mutual Attention Fusion with Region Awareness for Breast Cancer Diagnosis via Imbalanced Data.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1