管道嵌入式建筑围护结构与弧形翅片充热系统集成的综合性能数值研究

IF 6.1 2区 工程技术 Q2 ENERGY & FUELS Applied Thermal Engineering Pub Date : 2024-09-08 DOI:10.1016/j.applthermaleng.2024.124362
{"title":"管道嵌入式建筑围护结构与弧形翅片充热系统集成的综合性能数值研究","authors":"","doi":"10.1016/j.applthermaleng.2024.124362","DOIUrl":null,"url":null,"abstract":"<div><p>In the context of accelerating toward carbon neutrality, building envelopes are gradually regarded as multifunctional units with structural and energy attributes. To address the capacity mismatch between heat injection and thermal diffusion processes that hinder performance improvement of pipe-embedded energy walls, the arc-finned pipe-embedded energy walls (i.e., Arc-finPEWs) with directional heat-charging capacity are put forward. Subsequently, a validated mathematical model is established to explore the transient thermal behaviors of Arc-finPEWs as well as the impacts of 7 key parameters on its energy-saving potentials. Results showed that the directional heat-charging measures could improve the heat-charging capacity in specified directions, and the enhancement effect was more obvious as pipe spacing increased. Besides, the fin number (FN), shank length (SL), and fin angle (FA) were the top three influencing parameters in auxiliary-heating mode, whereas impacts of FA, FN, and arc angle (AA) ranked the top three in load-reduction mode. Furthermore, a larger FN and SL contributed to reducing total primary energy consumption and creating more robust invisible thermal barriers in auxiliary-heating mode, while left-facing fins or SL settings that are too high or too low were unfavorable in load-reduction mode. Meanwhile, the arc-fin designs with SL=0.6, FA=150° and AA=30° in auxiliary-heating mode and FA=30°, SL≤0.4 and AA≤15° in load-reduction mode are suggested. Compared to conventional energy-saving walls, the proposed arc-finned heat-charging system could reduce physical thermal insulation material usage with high embodied carbon features by over 60 %.</p></div>","PeriodicalId":8201,"journal":{"name":"Applied Thermal Engineering","volume":null,"pages":null},"PeriodicalIF":6.1000,"publicationDate":"2024-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical study on comprehensive performances of pipe-embedded building envelope integrated with arc-finned heat charging system\",\"authors\":\"\",\"doi\":\"10.1016/j.applthermaleng.2024.124362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In the context of accelerating toward carbon neutrality, building envelopes are gradually regarded as multifunctional units with structural and energy attributes. To address the capacity mismatch between heat injection and thermal diffusion processes that hinder performance improvement of pipe-embedded energy walls, the arc-finned pipe-embedded energy walls (i.e., Arc-finPEWs) with directional heat-charging capacity are put forward. Subsequently, a validated mathematical model is established to explore the transient thermal behaviors of Arc-finPEWs as well as the impacts of 7 key parameters on its energy-saving potentials. Results showed that the directional heat-charging measures could improve the heat-charging capacity in specified directions, and the enhancement effect was more obvious as pipe spacing increased. Besides, the fin number (FN), shank length (SL), and fin angle (FA) were the top three influencing parameters in auxiliary-heating mode, whereas impacts of FA, FN, and arc angle (AA) ranked the top three in load-reduction mode. Furthermore, a larger FN and SL contributed to reducing total primary energy consumption and creating more robust invisible thermal barriers in auxiliary-heating mode, while left-facing fins or SL settings that are too high or too low were unfavorable in load-reduction mode. Meanwhile, the arc-fin designs with SL=0.6, FA=150° and AA=30° in auxiliary-heating mode and FA=30°, SL≤0.4 and AA≤15° in load-reduction mode are suggested. Compared to conventional energy-saving walls, the proposed arc-finned heat-charging system could reduce physical thermal insulation material usage with high embodied carbon features by over 60 %.</p></div>\",\"PeriodicalId\":8201,\"journal\":{\"name\":\"Applied Thermal Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Thermal Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1359431124020301\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Thermal Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1359431124020301","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

在加速实现碳中和的背景下,建筑围护结构逐渐被视为具有结构和能源属性的多功能单元。针对热量注入和热扩散过程之间的能力不匹配阻碍了管道嵌入式节能墙性能的提高,提出了具有定向充热能力的弧形翅片管嵌入式节能墙(即 Arc-finPEW)。随后,建立了一个经过验证的数学模型,以探讨弧翅式能源墙的瞬态热行为以及 7 个关键参数对其节能潜力的影响。结果表明,定向充热措施可提高特定方向的充热能力,且随着管间距的增大,增强效果更加明显。此外,在辅助加热模式下,翅片数(FN)、翅片柄长(SL)和翅片角(FA)是影响最大的三个参数,而在减载模式下,FA、FN 和弧角(AA)的影响排在前三位。此外,在辅助加热模式下,较大的 FN 和 SL 有助于降低总一次能耗,并形成更坚固的隐形热障,而过高或过低的左向鳍片或 SL 设置则不利于减载模式。同时,建议在辅助加热模式下采用 SL=0.6、FA=150°、AA=30° 的弧形翅片设计,在减载模式下采用 FA=30°、SL≤0.4、AA≤15° 的弧形翅片设计。与传统的节能墙相比,所提出的弧翅式充热系统可减少 60% 以上具有高体现碳特征的物理保温材料用量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Numerical study on comprehensive performances of pipe-embedded building envelope integrated with arc-finned heat charging system

In the context of accelerating toward carbon neutrality, building envelopes are gradually regarded as multifunctional units with structural and energy attributes. To address the capacity mismatch between heat injection and thermal diffusion processes that hinder performance improvement of pipe-embedded energy walls, the arc-finned pipe-embedded energy walls (i.e., Arc-finPEWs) with directional heat-charging capacity are put forward. Subsequently, a validated mathematical model is established to explore the transient thermal behaviors of Arc-finPEWs as well as the impacts of 7 key parameters on its energy-saving potentials. Results showed that the directional heat-charging measures could improve the heat-charging capacity in specified directions, and the enhancement effect was more obvious as pipe spacing increased. Besides, the fin number (FN), shank length (SL), and fin angle (FA) were the top three influencing parameters in auxiliary-heating mode, whereas impacts of FA, FN, and arc angle (AA) ranked the top three in load-reduction mode. Furthermore, a larger FN and SL contributed to reducing total primary energy consumption and creating more robust invisible thermal barriers in auxiliary-heating mode, while left-facing fins or SL settings that are too high or too low were unfavorable in load-reduction mode. Meanwhile, the arc-fin designs with SL=0.6, FA=150° and AA=30° in auxiliary-heating mode and FA=30°, SL≤0.4 and AA≤15° in load-reduction mode are suggested. Compared to conventional energy-saving walls, the proposed arc-finned heat-charging system could reduce physical thermal insulation material usage with high embodied carbon features by over 60 %.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Thermal Engineering
Applied Thermal Engineering 工程技术-工程:机械
CiteScore
11.30
自引率
15.60%
发文量
1474
审稿时长
57 days
期刊介绍: Applied Thermal Engineering disseminates novel research related to the design, development and demonstration of components, devices, equipment, technologies and systems involving thermal processes for the production, storage, utilization and conservation of energy, with a focus on engineering application. The journal publishes high-quality and high-impact Original Research Articles, Review Articles, Short Communications and Letters to the Editor on cutting-edge innovations in research, and recent advances or issues of interest to the thermal engineering community.
期刊最新文献
Experimental and numerical study on critical oxygen concentration for shale gas detonation induced by oxygen-enriched combustion Thermal performance investigation of latent heat-packed bed thermal energy storage system with axial gas injection Investigation on flow excursion of transpiration cooling under supercritical pressure Enhancement of net output power of thermoelectric modules with a novel air-water combination Performance and energy consumption study of a dual-evaporator loop heat pipe for chip-level cooling
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1