Yue Zhang , Ping Ping , Xinyi Dai , Chentong Li , Zheng Li , Ping Zhuo , Liang Tang , Depeng Kong , Xiaokang Yin
{"title":"电弧故障诱发锂离子电池的失效机理和热失控行为","authors":"Yue Zhang , Ping Ping , Xinyi Dai , Chentong Li , Zheng Li , Ping Zhuo , Liang Tang , Depeng Kong , Xiaokang Yin","doi":"10.1016/j.rser.2024.114914","DOIUrl":null,"url":null,"abstract":"<div><p>As the widespread of lithium-ion battery systems such as electric vehicles and energy storage systems, the number of safety incidents due to electrical faults are increasing. Many accident reports have demonstrated that arc faults have become one of the main triggers of LIB system accidents, however, the related studies are inadequate. In this study, an arc imitation system is employed to investigate the influence of different arc energies on battery safety valve, as well as the electrochemical characteristics of faulty batteries. The results show that the minimum arc power to breach the safety valve ranges from 110 to 441 W. The maximum temperature rise rate on the battery surface can exceed 15 °C/s with arc power of around 1000 W. Further, the testing of in-situ and ex-situ indicate the faulty batteries undergo degradation and failure due to that moisture in the air enters the battery interior, resulting in increased internal resistance, loss of active materials and cyclable lithium. Finally, the faulty battery has no valve opening during thermal runaway, and the ignition time is four hundred seconds earlier than that of the normal battery, indicating more severe fire dangers. The results are valuable for safety design of battery systems in relation to arc faults, as well as the characteristic for fault detection and early warning.</p></div>","PeriodicalId":418,"journal":{"name":"Renewable and Sustainable Energy Reviews","volume":"207 ","pages":"Article 114914"},"PeriodicalIF":16.3000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1364032124006403/pdfft?md5=8f03e57a32c1b119cae0ef536d7c9f36&pid=1-s2.0-S1364032124006403-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Failure mechanism and thermal runaway behavior of lithium-ion battery induced by arc faults\",\"authors\":\"Yue Zhang , Ping Ping , Xinyi Dai , Chentong Li , Zheng Li , Ping Zhuo , Liang Tang , Depeng Kong , Xiaokang Yin\",\"doi\":\"10.1016/j.rser.2024.114914\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>As the widespread of lithium-ion battery systems such as electric vehicles and energy storage systems, the number of safety incidents due to electrical faults are increasing. Many accident reports have demonstrated that arc faults have become one of the main triggers of LIB system accidents, however, the related studies are inadequate. In this study, an arc imitation system is employed to investigate the influence of different arc energies on battery safety valve, as well as the electrochemical characteristics of faulty batteries. The results show that the minimum arc power to breach the safety valve ranges from 110 to 441 W. The maximum temperature rise rate on the battery surface can exceed 15 °C/s with arc power of around 1000 W. Further, the testing of in-situ and ex-situ indicate the faulty batteries undergo degradation and failure due to that moisture in the air enters the battery interior, resulting in increased internal resistance, loss of active materials and cyclable lithium. Finally, the faulty battery has no valve opening during thermal runaway, and the ignition time is four hundred seconds earlier than that of the normal battery, indicating more severe fire dangers. The results are valuable for safety design of battery systems in relation to arc faults, as well as the characteristic for fault detection and early warning.</p></div>\",\"PeriodicalId\":418,\"journal\":{\"name\":\"Renewable and Sustainable Energy Reviews\",\"volume\":\"207 \",\"pages\":\"Article 114914\"},\"PeriodicalIF\":16.3000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1364032124006403/pdfft?md5=8f03e57a32c1b119cae0ef536d7c9f36&pid=1-s2.0-S1364032124006403-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Renewable and Sustainable Energy Reviews\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1364032124006403\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Renewable and Sustainable Energy Reviews","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1364032124006403","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Failure mechanism and thermal runaway behavior of lithium-ion battery induced by arc faults
As the widespread of lithium-ion battery systems such as electric vehicles and energy storage systems, the number of safety incidents due to electrical faults are increasing. Many accident reports have demonstrated that arc faults have become one of the main triggers of LIB system accidents, however, the related studies are inadequate. In this study, an arc imitation system is employed to investigate the influence of different arc energies on battery safety valve, as well as the electrochemical characteristics of faulty batteries. The results show that the minimum arc power to breach the safety valve ranges from 110 to 441 W. The maximum temperature rise rate on the battery surface can exceed 15 °C/s with arc power of around 1000 W. Further, the testing of in-situ and ex-situ indicate the faulty batteries undergo degradation and failure due to that moisture in the air enters the battery interior, resulting in increased internal resistance, loss of active materials and cyclable lithium. Finally, the faulty battery has no valve opening during thermal runaway, and the ignition time is four hundred seconds earlier than that of the normal battery, indicating more severe fire dangers. The results are valuable for safety design of battery systems in relation to arc faults, as well as the characteristic for fault detection and early warning.
期刊介绍:
The mission of Renewable and Sustainable Energy Reviews is to disseminate the most compelling and pertinent critical insights in renewable and sustainable energy, fostering collaboration among the research community, private sector, and policy and decision makers. The journal aims to exchange challenges, solutions, innovative concepts, and technologies, contributing to sustainable development, the transition to a low-carbon future, and the attainment of emissions targets outlined by the United Nations Framework Convention on Climate Change.
Renewable and Sustainable Energy Reviews publishes a diverse range of content, including review papers, original research, case studies, and analyses of new technologies, all featuring a substantial review component such as critique, comparison, or analysis. Introducing a distinctive paper type, Expert Insights, the journal presents commissioned mini-reviews authored by field leaders, addressing topics of significant interest. Case studies undergo consideration only if they showcase the work's applicability to other regions or contribute valuable insights to the broader field of renewable and sustainable energy. Notably, a bibliographic or literature review lacking critical analysis is deemed unsuitable for publication.