Álvaro Morales López , Akanksha Appaiah , Johan Berglund , Klas Marteleur , Fatemeh Ajalloueian , Anna Finne-Wistrand
{"title":"环氧乙烷和伽马射线灭菌对薄膜和电纺聚(ε-己内酯-共对二氧杂环戊酮)(PCLDX)支架表面纹理的影响","authors":"Álvaro Morales López , Akanksha Appaiah , Johan Berglund , Klas Marteleur , Fatemeh Ajalloueian , Anna Finne-Wistrand","doi":"10.1016/j.polymertesting.2024.108567","DOIUrl":null,"url":null,"abstract":"<div><p>In the field of tissue engineering, synthetic and degradable polyesters like poly(ε-caprolactone) (PCL) and poly(ε-caprolactone-co-p-dioxanone) (PCLDX) are widely used as scaffolds. Our previous research revealed that thermal storage conditions could alter the surface texture of PCL and PCLDX scaffolds, which might influence cell-scaffold interactions in tissue engineering applications. These findings highlighted the importance of multi-scale characterization techniques to identify the scales most sensitive to external changes and the need for personalized surface texture analysis. Sterilization techniques, such as ethylene oxide and gamma radiation, are essential for ensuring the sterility of polymeric medical devices. However, these processes can significantly impact the bulk polymer properties and/or surface texture of the scaffolds, potentially affecting their biocompatibility, safety, and overall performance. Therefore, the influence of sterilization processes on the surface texture of PCLDX films and electrospun nanofibers and to correlate these findings with the thermal and physical properties of the polymer are essential and have been assessed. Our results demonstrated that ethylene oxide maintained the structural integrity and surface texture of PCLDX scaffolds, while gamma irradiation caused a significant reduction in molar mass and increased the number of hills (Shn) and dales (Sdn) on PCLDX samples. Despite these changes, both sterilization methods showed minimal effects on the thermal properties, such as melting temperature and degree of crystallinity, and surface wettability of the scaffolds. This comprehensive surface texture analysis highlights the importance of evaluating feature parameters such as Shn and Sdn for optimizing the performance and biocompatibility of polymeric scaffolds in tissue engineering.</p></div>","PeriodicalId":20628,"journal":{"name":"Polymer Testing","volume":"139 ","pages":"Article 108567"},"PeriodicalIF":5.0000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0142941824002447/pdfft?md5=39e024c0bb7a3aa99ca6b7a0e546d5ea&pid=1-s2.0-S0142941824002447-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Effect of ethylene oxide and gamma sterilization on surface texture of films and electrospun poly(ε-caprolactone-co-p-dioxanone) (PCLDX) scaffolds\",\"authors\":\"Álvaro Morales López , Akanksha Appaiah , Johan Berglund , Klas Marteleur , Fatemeh Ajalloueian , Anna Finne-Wistrand\",\"doi\":\"10.1016/j.polymertesting.2024.108567\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In the field of tissue engineering, synthetic and degradable polyesters like poly(ε-caprolactone) (PCL) and poly(ε-caprolactone-co-p-dioxanone) (PCLDX) are widely used as scaffolds. Our previous research revealed that thermal storage conditions could alter the surface texture of PCL and PCLDX scaffolds, which might influence cell-scaffold interactions in tissue engineering applications. These findings highlighted the importance of multi-scale characterization techniques to identify the scales most sensitive to external changes and the need for personalized surface texture analysis. Sterilization techniques, such as ethylene oxide and gamma radiation, are essential for ensuring the sterility of polymeric medical devices. However, these processes can significantly impact the bulk polymer properties and/or surface texture of the scaffolds, potentially affecting their biocompatibility, safety, and overall performance. Therefore, the influence of sterilization processes on the surface texture of PCLDX films and electrospun nanofibers and to correlate these findings with the thermal and physical properties of the polymer are essential and have been assessed. Our results demonstrated that ethylene oxide maintained the structural integrity and surface texture of PCLDX scaffolds, while gamma irradiation caused a significant reduction in molar mass and increased the number of hills (Shn) and dales (Sdn) on PCLDX samples. Despite these changes, both sterilization methods showed minimal effects on the thermal properties, such as melting temperature and degree of crystallinity, and surface wettability of the scaffolds. This comprehensive surface texture analysis highlights the importance of evaluating feature parameters such as Shn and Sdn for optimizing the performance and biocompatibility of polymeric scaffolds in tissue engineering.</p></div>\",\"PeriodicalId\":20628,\"journal\":{\"name\":\"Polymer Testing\",\"volume\":\"139 \",\"pages\":\"Article 108567\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0142941824002447/pdfft?md5=39e024c0bb7a3aa99ca6b7a0e546d5ea&pid=1-s2.0-S0142941824002447-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polymer Testing\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0142941824002447\",\"RegionNum\":2,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MATERIALS SCIENCE, CHARACTERIZATION & TESTING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polymer Testing","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142941824002447","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
Effect of ethylene oxide and gamma sterilization on surface texture of films and electrospun poly(ε-caprolactone-co-p-dioxanone) (PCLDX) scaffolds
In the field of tissue engineering, synthetic and degradable polyesters like poly(ε-caprolactone) (PCL) and poly(ε-caprolactone-co-p-dioxanone) (PCLDX) are widely used as scaffolds. Our previous research revealed that thermal storage conditions could alter the surface texture of PCL and PCLDX scaffolds, which might influence cell-scaffold interactions in tissue engineering applications. These findings highlighted the importance of multi-scale characterization techniques to identify the scales most sensitive to external changes and the need for personalized surface texture analysis. Sterilization techniques, such as ethylene oxide and gamma radiation, are essential for ensuring the sterility of polymeric medical devices. However, these processes can significantly impact the bulk polymer properties and/or surface texture of the scaffolds, potentially affecting their biocompatibility, safety, and overall performance. Therefore, the influence of sterilization processes on the surface texture of PCLDX films and electrospun nanofibers and to correlate these findings with the thermal and physical properties of the polymer are essential and have been assessed. Our results demonstrated that ethylene oxide maintained the structural integrity and surface texture of PCLDX scaffolds, while gamma irradiation caused a significant reduction in molar mass and increased the number of hills (Shn) and dales (Sdn) on PCLDX samples. Despite these changes, both sterilization methods showed minimal effects on the thermal properties, such as melting temperature and degree of crystallinity, and surface wettability of the scaffolds. This comprehensive surface texture analysis highlights the importance of evaluating feature parameters such as Shn and Sdn for optimizing the performance and biocompatibility of polymeric scaffolds in tissue engineering.
期刊介绍:
Polymer Testing focuses on the testing, analysis and characterization of polymer materials, including both synthetic and natural or biobased polymers. Novel testing methods and the testing of novel polymeric materials in bulk, solution and dispersion is covered. In addition, we welcome the submission of the testing of polymeric materials for a wide range of applications and industrial products as well as nanoscale characterization.
The scope includes but is not limited to the following main topics:
Novel testing methods and Chemical analysis
• mechanical, thermal, electrical, chemical, imaging, spectroscopy, scattering and rheology
Physical properties and behaviour of novel polymer systems
• nanoscale properties, morphology, transport properties
Degradation and recycling of polymeric materials when combined with novel testing or characterization methods
• degradation, biodegradation, ageing and fire retardancy
Modelling and Simulation work will be only considered when it is linked to new or previously published experimental results.