受自然启发的辅助支架的有限元分析和代用优化设计。

IF 1.7 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS Computer Methods in Biomechanics and Biomedical Engineering Pub Date : 2024-09-10 DOI:10.1080/10255842.2024.2399018
Y W Teong,K B Mustapha,Morufu Olusola Ibitoye
{"title":"受自然启发的辅助支架的有限元分析和代用优化设计。","authors":"Y W Teong,K B Mustapha,Morufu Olusola Ibitoye","doi":"10.1080/10255842.2024.2399018","DOIUrl":null,"url":null,"abstract":"Prior studies have revealed that the structural design of stents is critical to reducing some of the alarming post-operative complications associated with stent-related intervention. However, the technical search for stents that guarantee robustness against stent-induced post-intervention complications remains an open problem. Along this objective, this study investigates a re-entrant auxetic stent's structural response and performance optimizations. In pursuit of the goal, a nonlinear finite element analysis (FEA) is employed to uncover metrics characterizing the auxetic stent's mechanical behavior. Subsequently, the non-dominated sorting genetic algorithm (NSGA-II) is implemented to simultaneously minimize the stent's von Mises stress and the elastic radial recoil (ERR). Results from the FEA revealed a tight connection between the stent's response and the features of the base auxetic building block (the rib length, strut width, and the re-entrant angle). It is observed that the auxetic stent exhibits a much lower ERR. Besides, larger values of its rib length and re-entrant angle are noticed to favor smaller von Mises stress. The Pareto-optimal front from the NSGA-II-based optimization scheme revealed a sharp trade-off in the simultaneous minimization of the von Mises stress and the ERR. Moreover, an optimal combination of the auxetic unit cell's geometric parameters is found to yield a much lower maximum von Mises stress of ≈403 MPa and ERR of ≈0.4%.","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Finite element analysis and surrogate-optimized design of a nature-inspired auxetic stent.\",\"authors\":\"Y W Teong,K B Mustapha,Morufu Olusola Ibitoye\",\"doi\":\"10.1080/10255842.2024.2399018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Prior studies have revealed that the structural design of stents is critical to reducing some of the alarming post-operative complications associated with stent-related intervention. However, the technical search for stents that guarantee robustness against stent-induced post-intervention complications remains an open problem. Along this objective, this study investigates a re-entrant auxetic stent's structural response and performance optimizations. In pursuit of the goal, a nonlinear finite element analysis (FEA) is employed to uncover metrics characterizing the auxetic stent's mechanical behavior. Subsequently, the non-dominated sorting genetic algorithm (NSGA-II) is implemented to simultaneously minimize the stent's von Mises stress and the elastic radial recoil (ERR). Results from the FEA revealed a tight connection between the stent's response and the features of the base auxetic building block (the rib length, strut width, and the re-entrant angle). It is observed that the auxetic stent exhibits a much lower ERR. Besides, larger values of its rib length and re-entrant angle are noticed to favor smaller von Mises stress. The Pareto-optimal front from the NSGA-II-based optimization scheme revealed a sharp trade-off in the simultaneous minimization of the von Mises stress and the ERR. Moreover, an optimal combination of the auxetic unit cell's geometric parameters is found to yield a much lower maximum von Mises stress of ≈403 MPa and ERR of ≈0.4%.\",\"PeriodicalId\":50640,\"journal\":{\"name\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10255842.2024.2399018\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2024.2399018","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

摘要

先前的研究表明,支架的结构设计对于减少与支架相关的介入治疗引起的一些令人担忧的术后并发症至关重要。然而,如何从技术上寻求支架,以确保其坚固耐用,防止支架引发介入术后并发症,仍是一个有待解决的问题。根据这一目标,本研究对再入式辅助支架的结构响应和性能优化进行了研究。为了实现这一目标,我们采用了非线性有限元分析(FEA)来揭示辅助支架机械行为的特征指标。随后,采用非支配排序遗传算法(NSGA-II)同时最小化支架的冯米塞斯应力和弹性径向反冲(ERR)。有限元分析的结果表明,支架的响应与基础辅助构件的特征(肋骨长度、支柱宽度和再入角等)密切相关。可以看出,辅助支架的等效误差要小得多。此外,肋长和再入角值越大,von Mises 应力越小。基于 NSGA-II 的优化方案得出的帕累托最优前沿显示,在同时最小化 von Mises 应力和 ERR 的过程中,存在着急剧的权衡。此外,还发现辅助单元几何参数的最佳组合可产生更低的最大 von Mises 应力(≈403 兆帕)和ERR(≈0.4%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Finite element analysis and surrogate-optimized design of a nature-inspired auxetic stent.
Prior studies have revealed that the structural design of stents is critical to reducing some of the alarming post-operative complications associated with stent-related intervention. However, the technical search for stents that guarantee robustness against stent-induced post-intervention complications remains an open problem. Along this objective, this study investigates a re-entrant auxetic stent's structural response and performance optimizations. In pursuit of the goal, a nonlinear finite element analysis (FEA) is employed to uncover metrics characterizing the auxetic stent's mechanical behavior. Subsequently, the non-dominated sorting genetic algorithm (NSGA-II) is implemented to simultaneously minimize the stent's von Mises stress and the elastic radial recoil (ERR). Results from the FEA revealed a tight connection between the stent's response and the features of the base auxetic building block (the rib length, strut width, and the re-entrant angle). It is observed that the auxetic stent exhibits a much lower ERR. Besides, larger values of its rib length and re-entrant angle are noticed to favor smaller von Mises stress. The Pareto-optimal front from the NSGA-II-based optimization scheme revealed a sharp trade-off in the simultaneous minimization of the von Mises stress and the ERR. Moreover, an optimal combination of the auxetic unit cell's geometric parameters is found to yield a much lower maximum von Mises stress of ≈403 MPa and ERR of ≈0.4%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
期刊最新文献
Reconstruction of blood flow velocity with deep learning information fusion from spectral ct projections and vessel geometry. Reduction of material groups for vertebral bone finite element simulation: cross comparison of grouping methods. Accurate detection of gait events using neural networks and IMU data mimicking real-world smartphone usage. Exploring coronavirus sequence motifs through convolutional neural network for accurate identification of COVID-19. Coexistence of horizontal bone loss and dehiscence with the bundle and conventional fiber post: a finite element analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1