{"title":"在光学车间测试中使用双射影克的改进型傅科方法","authors":"Xiang Hua, Jianqiang Zhu, Zhaoyang Jiao","doi":"10.1063/5.0222121","DOIUrl":null,"url":null,"abstract":"The lack of rapid, effective, and quantitative testing methods in the initial stages of optical processing has been identified as a significant challenge. In response, an innovative approach has been developed to enhance the Foucault knife-edge test method, integrating digital image processing and spatial geometry algorithms. This has resulted in the creation of a convenient and rapid optical testing method, which has been successfully implemented in practice. The method requires the collection of only two knife-edge shadow grams, which are then subjected to calculation. This enables the theoretical results of the knife-edge shadow gram at the focal point, and the reference results of the wavefront surface processing error of the mirror to be measured can be obtained. The method can be well applied to the testing work of optical workshops and provides a guiding solution with better performance for optical testing than the traditional knife-edge testing method.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improved Foucault method with double-shoot shadow grams in optical shop testing\",\"authors\":\"Xiang Hua, Jianqiang Zhu, Zhaoyang Jiao\",\"doi\":\"10.1063/5.0222121\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The lack of rapid, effective, and quantitative testing methods in the initial stages of optical processing has been identified as a significant challenge. In response, an innovative approach has been developed to enhance the Foucault knife-edge test method, integrating digital image processing and spatial geometry algorithms. This has resulted in the creation of a convenient and rapid optical testing method, which has been successfully implemented in practice. The method requires the collection of only two knife-edge shadow grams, which are then subjected to calculation. This enables the theoretical results of the knife-edge shadow gram at the focal point, and the reference results of the wavefront surface processing error of the mirror to be measured can be obtained. The method can be well applied to the testing work of optical workshops and provides a guiding solution with better performance for optical testing than the traditional knife-edge testing method.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0222121\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0222121","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Improved Foucault method with double-shoot shadow grams in optical shop testing
The lack of rapid, effective, and quantitative testing methods in the initial stages of optical processing has been identified as a significant challenge. In response, an innovative approach has been developed to enhance the Foucault knife-edge test method, integrating digital image processing and spatial geometry algorithms. This has resulted in the creation of a convenient and rapid optical testing method, which has been successfully implemented in practice. The method requires the collection of only two knife-edge shadow grams, which are then subjected to calculation. This enables the theoretical results of the knife-edge shadow gram at the focal point, and the reference results of the wavefront surface processing error of the mirror to be measured can be obtained. The method can be well applied to the testing work of optical workshops and provides a guiding solution with better performance for optical testing than the traditional knife-edge testing method.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.