用于 COSINUS 干法稀释冰箱中 TES 运行的振动去耦系统

IF 1.1 3区 物理与天体物理 Q4 PHYSICS, APPLIED Journal of Low Temperature Physics Pub Date : 2024-09-03 DOI:10.1007/s10909-024-03206-x
M. Kellermann, G. Angloher, M. R. Bharadawj, M. Cababie, I. Dafinei, N. Di Marco, L. Einfalt, F. Ferroni, S. Fichtinger, A. Filipponi, T. Frank, M. Friedl, Z. Ge, M. Heikinheimo, M. N. Hughes, K. Huitu, R. Maji, M. Mancuso, L. Pagnanini, F. Petricca, S. Pirro, F. Pröbst, G. Profeta, A. Puiu, F. Reindl, K. Schäffner, J. Schieck, D. Schmiedmayer, P. Schreiner, C. Schwertner, M. Stahlberg, A. Stendahl, M. J. Stukel, C. Tresca, F. Wagner, S. Yue, V. Zema, Y. Zhu
{"title":"用于 COSINUS 干法稀释冰箱中 TES 运行的振动去耦系统","authors":"M. Kellermann,&nbsp;G. Angloher,&nbsp;M. R. Bharadawj,&nbsp;M. Cababie,&nbsp;I. Dafinei,&nbsp;N. Di Marco,&nbsp;L. Einfalt,&nbsp;F. Ferroni,&nbsp;S. Fichtinger,&nbsp;A. Filipponi,&nbsp;T. Frank,&nbsp;M. Friedl,&nbsp;Z. Ge,&nbsp;M. Heikinheimo,&nbsp;M. N. Hughes,&nbsp;K. Huitu,&nbsp;R. Maji,&nbsp;M. Mancuso,&nbsp;L. Pagnanini,&nbsp;F. Petricca,&nbsp;S. Pirro,&nbsp;F. Pröbst,&nbsp;G. Profeta,&nbsp;A. Puiu,&nbsp;F. Reindl,&nbsp;K. Schäffner,&nbsp;J. Schieck,&nbsp;D. Schmiedmayer,&nbsp;P. Schreiner,&nbsp;C. Schwertner,&nbsp;M. Stahlberg,&nbsp;A. Stendahl,&nbsp;M. J. Stukel,&nbsp;C. Tresca,&nbsp;F. Wagner,&nbsp;S. Yue,&nbsp;V. Zema,&nbsp;Y. Zhu","doi":"10.1007/s10909-024-03206-x","DOIUrl":null,"url":null,"abstract":"<div><p>COSINUS will be among the first underground experiments to operate Transition Edge Sensors in a dry dilution refrigerator, measuring temperature changes on the order of <span>\\(\\mu\\)</span>K. A pulse tube cryocooler is used to cool down to 3K, trading simplified handling, by not using liquid noble gases, for an increased vibration noise level in the acoustic frequency range. As the signals measured with a TES are in the same frequency region, it is necessary to decouple the detectors from all possible noise sources. In COSINUS, a two-level passive decoupling system was developed and tested using piezo-based accelerometers. At the first level, the refrigerator is mechanically isolated from all external noise sources. For the second level an internal spring-based system was developed and tested on a mockup system. On the first level a reduction of the vibrational background up to a factor 4 below 10 Hz could be measured. On the second level a resonance frequency of 1.2 Hz with damping of higher frequencies was achieved.</p></div>","PeriodicalId":641,"journal":{"name":"Journal of Low Temperature Physics","volume":"217 Part 4","pages":"418 - 425"},"PeriodicalIF":1.1000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10909-024-03206-x.pdf","citationCount":"0","resultStr":"{\"title\":\"A Vibration Decoupling System for TES Operation in the COSINUS Dry Dilution Refrigerator\",\"authors\":\"M. Kellermann,&nbsp;G. Angloher,&nbsp;M. R. Bharadawj,&nbsp;M. Cababie,&nbsp;I. Dafinei,&nbsp;N. Di Marco,&nbsp;L. Einfalt,&nbsp;F. Ferroni,&nbsp;S. Fichtinger,&nbsp;A. Filipponi,&nbsp;T. Frank,&nbsp;M. Friedl,&nbsp;Z. Ge,&nbsp;M. Heikinheimo,&nbsp;M. N. Hughes,&nbsp;K. Huitu,&nbsp;R. Maji,&nbsp;M. Mancuso,&nbsp;L. Pagnanini,&nbsp;F. Petricca,&nbsp;S. Pirro,&nbsp;F. Pröbst,&nbsp;G. Profeta,&nbsp;A. Puiu,&nbsp;F. Reindl,&nbsp;K. Schäffner,&nbsp;J. Schieck,&nbsp;D. Schmiedmayer,&nbsp;P. Schreiner,&nbsp;C. Schwertner,&nbsp;M. Stahlberg,&nbsp;A. Stendahl,&nbsp;M. J. Stukel,&nbsp;C. Tresca,&nbsp;F. Wagner,&nbsp;S. Yue,&nbsp;V. Zema,&nbsp;Y. Zhu\",\"doi\":\"10.1007/s10909-024-03206-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>COSINUS will be among the first underground experiments to operate Transition Edge Sensors in a dry dilution refrigerator, measuring temperature changes on the order of <span>\\\\(\\\\mu\\\\)</span>K. A pulse tube cryocooler is used to cool down to 3K, trading simplified handling, by not using liquid noble gases, for an increased vibration noise level in the acoustic frequency range. As the signals measured with a TES are in the same frequency region, it is necessary to decouple the detectors from all possible noise sources. In COSINUS, a two-level passive decoupling system was developed and tested using piezo-based accelerometers. At the first level, the refrigerator is mechanically isolated from all external noise sources. For the second level an internal spring-based system was developed and tested on a mockup system. On the first level a reduction of the vibrational background up to a factor 4 below 10 Hz could be measured. On the second level a resonance frequency of 1.2 Hz with damping of higher frequencies was achieved.</p></div>\",\"PeriodicalId\":641,\"journal\":{\"name\":\"Journal of Low Temperature Physics\",\"volume\":\"217 Part 4\",\"pages\":\"418 - 425\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s10909-024-03206-x.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Low Temperature Physics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10909-024-03206-x\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Low Temperature Physics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s10909-024-03206-x","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

摘要

COSINUS将是第一批在干稀释冰箱中运行过渡边缘传感器的地下实验之一,测量的温度变化量级为\(\mu\)K。使用脉冲管低温冷却器将温度降到 3K,不使用液态惰性气体,从而简化了操作,但声频范围内的振动噪声水平却增加了。由于使用 TES 测量的信号处于同一频率区域,因此有必要将探测器与所有可能的噪声源去耦。COSINUS 利用压电式加速度计开发并测试了两级无源去耦系统。在第一级,冰箱与所有外部噪声源进行了机械隔离。在第二层,开发了一个基于内部弹簧的系统,并在模拟系统上进行了测试。在第一层,可以测量到低于 10 赫兹的振动背景降低了 4 倍。在第二层,共振频率为 1.2 Hz,对较高频率有阻尼作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Vibration Decoupling System for TES Operation in the COSINUS Dry Dilution Refrigerator

COSINUS will be among the first underground experiments to operate Transition Edge Sensors in a dry dilution refrigerator, measuring temperature changes on the order of \(\mu\)K. A pulse tube cryocooler is used to cool down to 3K, trading simplified handling, by not using liquid noble gases, for an increased vibration noise level in the acoustic frequency range. As the signals measured with a TES are in the same frequency region, it is necessary to decouple the detectors from all possible noise sources. In COSINUS, a two-level passive decoupling system was developed and tested using piezo-based accelerometers. At the first level, the refrigerator is mechanically isolated from all external noise sources. For the second level an internal spring-based system was developed and tested on a mockup system. On the first level a reduction of the vibrational background up to a factor 4 below 10 Hz could be measured. On the second level a resonance frequency of 1.2 Hz with damping of higher frequencies was achieved.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Low Temperature Physics
Journal of Low Temperature Physics 物理-物理:凝聚态物理
CiteScore
3.30
自引率
25.00%
发文量
245
审稿时长
1 months
期刊介绍: The Journal of Low Temperature Physics publishes original papers and review articles on all areas of low temperature physics and cryogenics, including theoretical and experimental contributions. Subject areas include: Quantum solids, liquids and gases; Superfluidity; Superconductivity; Condensed matter physics; Experimental techniques; The Journal encourages the submission of Rapid Communications and Special Issues.
期刊最新文献
Enhanced Stability of Self-Bound Droplets in Quasi-One Dimension via Interspecies Quantum Fluctuations in Ultracold Bose–Bose Mixtures Superconductivity in Alkali Metal-Deposited Monolayer BC: MBC (M = Na, K) On the Superstatistical Properties of the Klein-Gordon Oscillator Using Gamma, Log, and F Distributions The Magnetic Microbolometer Detection Chain: A Proposed Detection System to Observe the B Modes of the Cosmic Microwave Background Tutorial: From Topology to Hall Effects—Implications of Berry Phase Physics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1